Catalog excerpts
SIF 6 Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contacts Insulation Data - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (>5,5 mm) and contacts side by side (>5,5mm) - IEC 61810-3 Type A - Double and reinforced insulation - SMD placement under relay possible - Contact mounting: SIF422 4 NO / 2 NC - Small height: only 10,9 mm - Nominal coil power 0,66 W - Holding coil power 0,20 W - Coil for railway application according EN 50155 on request Contact materialAgCuNi + 0,2 pm Au Type of contactSingle contact with notched crown Rated switching capacity250 VAC 8 A AC1 2000 VA Electr. Life AC1(360 S / h)approx.100000 Inrush current max.30 A for 20 ms Switching voltage range5 to 250 VDC / VAC Switching current range*3 mA to 8 A Switching capacity range*40 mW to 2 000 W(VA) Contact resistance (as delivered) <100 mfi / 6 V / 100 mA Ambient temperature Thermal Resistance Temperature limit for coil Weight Mounting position Mounting distance Contact Data *Guided values (other voltages on request) - Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistanceCTI 175 Pollution degree 2 Overvoltage categoryIII_ Insulation resistance at Up 500 VDC >100 MQ Mechanical endurance>10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed)typically 20 ms Drop-out time** (NC closed) typically 8 ms Bounce time of NO contacttypically 1,5 ms Bounce time of NC contact typically 15 ms (10-200 Hz)NC > 2g Resistance to short circuiting contacts NO 1000 A SCPD 10 A gG / gL (pre-fuse) Resistance to short circuiting contacts NC 1000 A SCPD 6 A gG / gL (pre-fuse) Test methodA / group assembly Type of protection RT II Solder bath temperature270°C / 5 s **without spark suppression Insulation class IEC 60664-1250 VAC Fire protection requirementsUL 94 / V0 Standards IEC 61810-1, IEC 61810-3 none available Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 8 A Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each 3 contacts with 6 A each 4 contacts with 4,5 A each 1) Max. excitation voltage with contact load: <5 A 2) Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%.
Open the catalog to page 1All ELESTA GmbH catalogs and technical brochures
-
SMD4 Series
1 Pages
-
SMF5 Series
1 Pages
-
SMF3 Series
1 Pages
-
SMD4 Series
1 Pages
-
SRD SIS3
1 Pages
-
Relay Accessories for Series
1 Pages
-
SRD SIM4
1 Pages
-
SRD SGR2
1 Pages
-
SRD SGR2A KV2 PIK
1 Pages
-
SIP6 Series
1 Pages
-
SIM4 Series
1 Pages
-
SIM3 Series
1 Pages
-
SIM2 Series
1 Pages
-
SGR282 ZK Series
1 Pages
-
SIF4 Series
1 Pages
-
SIF6 Series
1 Pages
-
SIF4 Series
1 Pages
-
SIF3 Series
1 Pages
-
SIS6 sensitive Series
1 Pages
-
SIS4 Series
1 Pages
-
SIS3 Series
1 Pages
-
SIS2 sensitive Series
1 Pages
-
SIS2 Series
1 Pages
-
SISF2 Series
1 Pages
-
SIR6 sensitive Series
1 Pages
-
SIR10 Series
1 Pages
-
SIR8 Series
1 Pages
-
SID4 Series
1 Pages
-
SIR 10 Series
1 Pages
-
SIR 8 Series
1 Pages
-
SIR 6 sensitive Series
1 Pages
-
SIR 6 Series
1 Pages
-
SIR 4 Power Series
1 Pages
-
SIR 4 sensitive Series
1 Pages
-
SIR 4 Series
1 Pages
-
SLR 4 Series
1 Pages
-
SIM 2 Series
1 Pages
-
SGR 282 ZK Series
1 Pages
-
SIF 4 Series
1 Pages
-
SIF 3 Series
1 Pages
-
SIS 6 sensitive Series
1 Pages
-
SIS 6 Series
1 Pages
-
SIS 4 sensitive Series
1 Pages
-
SIS 4 Series
1 Pages
-
SIS 3 Series
1 Pages
-
SIS 2 sensitive Series
1 Pages
-
SIS 2 Series
1 Pages
-
E OI R007 (DSET)
1 Pages
-
E OI R007 (CSV0)
1 Pages
Archived catalogs
-
Product Catalogue
36 Pages
-
Download Product catalogue 2008
36 Pages