SIF 6 Series
1 /1Page

SIF 6 Series

SIF 6 Series
1 /1Page

Catalog excerpts

SIF 6 Series-1

SIF 6 Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contacts Insulation Data - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (>5,5 mm) and contacts side by side (>5,5mm) - IEC 61810-3 Type A - Double and reinforced insulation - SMD placement under relay possible - Contact mounting: SIF422 4 NO / 2 NC - Small height: only 10,9 mm - Nominal coil power 0,66 W - Holding coil power 0,20 W - Coil for railway application according EN 50155 on request Contact materialAgCuNi + 0,2 pm Au Type of contactSingle contact with notched crown Rated switching capacity250 VAC 8 A AC1 2000 VA Electr. Life AC1(360 S / h)approx.100000 Inrush current max.30 A for 20 ms Switching voltage range5 to 250 VDC / VAC Switching current range*3 mA to 8 A Switching capacity range*40 mW to 2 000 W(VA) Contact resistance (as delivered) <100 mfi / 6 V / 100 mA Ambient temperature Thermal Resistance Temperature limit for coil Weight Mounting position Mounting distance Contact Data *Guided values (other voltages on request) - Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistanceCTI 175 Pollution degree 2 Overvoltage categoryIII_ Insulation resistance at Up 500 VDC >100 MQ Mechanical endurance>10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed)typically 20 ms Drop-out time** (NC closed) typically 8 ms Bounce time of NO contacttypically 1,5 ms Bounce time of NC contact typically 15 ms (10-200 Hz)NC > 2g Resistance to short circuiting contacts NO 1000 A SCPD 10 A gG / gL (pre-fuse) Resistance to short circuiting contacts NC 1000 A SCPD 6 A gG / gL (pre-fuse) Test methodA / group assembly Type of protection RT II Solder bath temperature270°C / 5 s **without spark suppression Insulation class IEC 60664-1250 VAC Fire protection requirementsUL 94 / V0 Standards IEC 61810-1, IEC 61810-3 none available Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 8 A Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each 3 contacts with 6 A each 4 contacts with 4,5 A each 1) Max. excitation voltage with contact load: <5 A 2) Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%.

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.