SIF 6 Series
1Pages

{{requestButtons}}

Catalog excerpts

SIF 6 Series - 1

SIF 6 Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contacts Insulation Data - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (>5,5 mm) and contacts side by side (>5,5mm) - IEC 61810-3 Type A - Double and reinforced insulation - SMD placement under relay possible - Contact mounting: SIF422 4 NO / 2 NC - Small height: only 10,9 mm - Nominal coil power 0,66 W - Holding coil power 0,20 W - Coil for railway application according EN 50155 on request Contact materialAgCuNi + 0,2 pm Au Type of contactSingle contact with notched crown Rated switching capacity250 VAC 8 A AC1 2000 VA Electr. Life AC1(360 S / h)approx.100000 Inrush current max.30 A for 20 ms Switching voltage range5 to 250 VDC / VAC Switching current range*3 mA to 8 A Switching capacity range*40 mW to 2 000 W(VA) Contact resistance (as delivered) <100 mfi / 6 V / 100 mA Ambient temperature Thermal Resistance Temperature limit for coil Weight Mounting position Mounting distance Contact Data *Guided values (other voltages on request) - Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistanceCTI 175 Pollution degree 2 Overvoltage categoryIII_ Insulation resistance at Up 500 VDC >100 MQ Mechanical endurance>10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed)typically 20 ms Drop-out time** (NC closed) typically 8 ms Bounce time of NO contacttypically 1,5 ms Bounce time of NC contact typically 15 ms (10-200 Hz)NC > 2g Resistance to short circuiting contacts NO 1000 A SCPD 10 A gG / gL (pre-fuse) Resistance to short circuiting contacts NC 1000 A SCPD 6 A gG / gL (pre-fuse) Test methodA / group assembly Type of protection RT II Solder bath temperature270°C / 5 s **without spark suppression Insulation class IEC 60664-1250 VAC Fire protection requirementsUL 94 / V0 Standards IEC 61810-1, IEC 61810-3 none available Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 8 A Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each 3 contacts with 6 A each 4 contacts with 4,5 A each 1) Max. excitation voltage with contact load: <5 A 2) Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%.

Open the catalog to page 1

All ELESTA GmbH catalogs and technical brochures

  1. SMD4 Series

    1 Pages

  2. SMF5 Series

    1 Pages

  3. SMF3 Series

    1 Pages

  4. SMD4 Series

    1 Pages

  5. SRD SIS3

    1 Pages

  6. SRD SIM4

    1 Pages

  7. SRD SGR2

    1 Pages

  8. SIP6 Series

    1 Pages

  9. SIM4 Series

    1 Pages

  10. SIM3 Series

    1 Pages

  11. SIM2 Series

    1 Pages

  12. SIF4 Series

    1 Pages

  13. SIF6 Series

    1 Pages

  14. SIF4 Series

    1 Pages

  15. SIF3 Series

    1 Pages

  16. SIS4 Series

    1 Pages

  17. SIS3 Series

    1 Pages

  18. SIS2 Series

    1 Pages

  19. SISF2 Series

    1 Pages

  20. SIR10 Series

    1 Pages

  21. SIR8 Series

    1 Pages

  22. SID4 Series

    1 Pages

  23. SIR 8 Series

    1 Pages

  24. SIR 6 Series

    1 Pages

  25. SIR 4 Series

    1 Pages

  26. SLR 4 Series

    1 Pages

  27. SIM 2 Series

    1 Pages

  28. SIF 4 Series

    1 Pages

  29. SIF 3 Series

    1 Pages

  30. SIS 6 Series

    1 Pages

  31. SIS 4 Series

    1 Pages

  32. SIS 3 Series

    1 Pages

  33. SIS 2 Series

    1 Pages

Archived catalogs