SIF 3 Series

SIF 3 Series

Product catalog summary
Insulation Data:
  • Double or reinforced insulation at 250 VAC.
  • Air and creepage distance >5.5 mm.
  • Test voltage: 4000 V / 50 Hz / 1 min; contact open: 1500 V / 50 Hz / 1 min.
  • Creepage resistance: CTI 175.
  • Pollution degree: 2.
  • Overvoltage category: III.
  • Insulation resistance at Up 500 VDC >100 MΩ.
Additional Data:
  • Mechanical endurance: >10 x 106 operations.
  • Switching frequency, mechanical: 15 Hz.
  • Response time (all NO closed): typically 12 ms.
  • Drop-out time (NC closed): typically 5 ms.
  • Bounce time of NO contact: typically 1.5 ms; NC contact: typically 15 ms.
  • Shock resistance: 16 ms NO > 15g, NC > 6g.
  • Vibration resistance: NO > 10g (10-200 Hz), NC > 2g.
  • Resistance to short circuiting contacts NO: 1000 A SCPD 10 A gG / gL (pre-fuse); NC: 1000 A SCPD 6 A gG / gL (pre-fuse).
  • Ambient temperature: -40°C to +70°C.
  • Thermal Resistance: 60 K / W.
  • Temperature limit for coil: 120°C.
  • Weight: approx. 18 g.
  • Mounting position: any; recommended mounting distance: >5 mm.
  • Test method: A / group assembly.
  • Type of protection: RT II.
  • Solder bath temperature: 270°C / 5 s.
Tests, Regulations, Standards:
  • Approvals: UL File E188953 Sec. 6.
  • Insulation class: IEC 60664-1 250 VAC.
  • Fire protection requirements: UL 94 / V0.
  • Standards: IEC 61810-1, IEC 61810-3.
Product Key:
  • SIF 2 1 2 24VDC.
  • Nominal voltage, solder terminals, number of NC contacts, number of NO contacts, type designation.
Contact Lifetime for NO Contacts:
  • AC 1:230V, DC 1: 24V, AC 15: 230V, DC 13: 24V.
  • Maximal switching characteristics (EN60947-5-1): AC 1: 250 V / 10 A, AC 15: 230 V / 5 A, DC 1: 24 V / 10 A, DC 13: 24 V / 5 A / 0.1 Hz.
  • UL 508: B300 / R300.
  • Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each.
Relay Key Data:
  • PCB relay with forcibly guided contacts.
  • Protective separation between coil and contacts (>5.5mm) and contacts side by side (>5.5mm).
  • IEC 61810-3 Type A.
  • Double and reinforced insulation between the contacts.
  • SMD placement under relay possible.
  • Contact mounting SIF212 2 NO / 1 NC.
  • Small overall height: Only 10.9 mm.
  • Nominal coil power: 0.60 W; Holding coil power: 0.18 W.
  • Coils for railway applications according to EN 50155 on request.
Contact Data:
  • Contact material: AgCuNi + 0.2 µm Au.
  • Type of contact: Single contact with notched crown.
  • Rated switching capacity: 250 VAC 10 A AC1 2500 VA.
  • Electrical Life AC1(360 S / h): approx.100000.
  • Inrush current max.: 30 A for 20 ms.
  • Switching voltage range: 5 to 250 VDC / VAC.
  • Switching current range: 3 mA to 10 A.
  • Switching capacity range: 40 mW to 2500 W(VA).
  • Contact resistance (as delivered): ≤100 mΩ / 6 V / 100 mA.
Standard Coils for Direct Current:
  • Nominal voltage VDC, Min. pick-up voltage VDC at 20°C, Drop-out voltage VDC at 20°C, Nominal current in mA at 20°C, Resistance in Ohm at 20°C.
See more

Catalog excerpts

SIF 3 Series-1

SIF 3 Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contacts - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (> 5,5mm) and contacts side by side (> 5,5mm) - IEC 61810-3 Type A - Double and reinforced insulation between the contacts - SMD placement under relay possible - Contact mounting SIF212 2 NO / 1 NC - Small overall height: Only 10,9 mm - Nominal coil power 0,60 W - Holding coil power 0,18 W - Coils for railway applications according to EN 50155 on request Contact materialAgCuNi + 0,2 pm Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 10 A AC1 2500 VA Electr. Life AC1(360 S / h) approx.100000 Inrush current max.30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range*3 mA to 10 A Switching capacity range* 40 mW to 2500 W(VA) Contact resistance (as delivered) <100 mQ / 6 V / 100 mA *Guided values Ambient temperature Thermal Resistance Temperature limit for coil Weight Mounting position Mounting distance Test method -40°C to +70°C 60 K / W _120°C approx. 18 g any rec. >5 mm A / group assembly Contact Data Standard Coils for Direct Current Insulation Data - Double or reinforced insulation at 250 VAC ^■ - Air and creepage distance >5,5 mm - Test voltage4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistanceCTI 175 Pollution degree 2 Overvoltage categoryIII_ Insulation resistance at Up 500 VDC >100 MQ Additional Data Mechanical endurance>10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed)typically 12 ms Drop-out time (NC closed) typically 5 ms Bounce time of NO contacttypically 1,5 ms Bounce time of NC contact typically 15 ms (10-200 Hz)NC > 2g Resistance to short circuiting contacts NO 1000 A SCPD 10 A gG / gL (pre-fuse) Resistance to short circuiting contacts NC 1000 A SCPD 6 A gG / gL (pre-fuse) Solder bath temperature270°C / 5 s **without spark suppression Tests, Regulations, Standards Fire protection requirementsUL 94 / V0 Standards IEC 61810-1, IEC 61810-3 Options, Accessories none available Switching Current (A) ^ Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 10 A Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each Load Limit Curve with Direct Current Voltage (VDC) ^ 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 1) Max. excitation voltage with contact load: <6 A 2) Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. ELESTA GmbH, Heuteilstrasse 18, Phone: +41 81 303 54 00CH - 7310 Bad Ragaz, Switzerland

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.