SGR 282 ZK Series
1Pages

{{requestButtons}}

Catalog excerpts

SGR 282 ZK Series - 1

SGR 282 ZK Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contacts >10 x 106 operations 15 Hz typically 12 ms typically 5 ms typically 4 ms typically 8 ms NO > 10g NC > 2,5g NO > 10g NC > 1,5g -40°C to +70°C 50 K / W _120°C approx. 20 g any rec. >5 mm A / group assembly RT II 270°C / 5 s Short-circuit resistance NO 1 000 A SCPD 10 A gG / gL (pre-fuse) - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (air and creepage distance >14 mm); protective separation between left and right contact side (air and creepage distance >5,5 mm) - IEC 61810-3 Type B - 2 changeover contacts with notch crown - Nominal coil power 0,7 W - Holding coil power 0,21 W Contact Data Contact materialAgCuNi + 0,2 pm Au Type of contact notched crown Rated switching capacity250 VAC 8 A AC1 2000 VA Electr. Life AC1(360 S / h) approx.100000 Inrush current max.15 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range*4 mA to 8 A Switching capacity range*50 mW to 2 000 W(VA) Contact resistance (as delivered) <100 mO / 28 V / 100 mA *Guided values Standard Coils for Direct Current (other voltages on request) Insulation Data - Double or reinforced insulation at 250 VAC - ■ — ■ - - Air and creepage distance >5,5 mm - Test voltage4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC ^■ - Air and creepage distance >14 mm - Test voltage5000 V / 50 Hz / 1 min Test voltage contact open1 500 V / 50 Hz / 1 min Creepage resistance CTI 550 Pollution degree2_ Overvoltage category III Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact_ Ambient temperature Thermal Resistance Temperature limit for coil Weight Mounting position Mounting distance Test method Type of protection Solder bath temperature **without spark suppression Tests, Regulations, Standards Insulation class IEC 60664-1250 VAC Fire protection requirementsUL 94 / V1 Standards IEC 61810-1, IEC 61810-3 Options, Accessories Switching Current (A) ^ Maximal switching capacity (DIN EN 60947-5-1, Tab. C2) AC 15: 230 V / 5 A Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each Load Limit Curve with Direct Current 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 1) Max. excitation voltage with contact load: <4 A 2) Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. Print socket, DIN-rail socket Wiring modules SGR282ZK 24VDC Nominal voltage Type designation

Open the catalog to page 1

All ELESTA GmbH catalogs and technical brochures

  1. SMD4 Series

    1 Pages

  2. SMF5 Series

    1 Pages

  3. SMF3 Series

    1 Pages

  4. SMD4 Series

    1 Pages

  5. SRD SIS3

    1 Pages

  6. SRD SIM4

    1 Pages

  7. SRD SGR2

    1 Pages

  8. SIP6 Series

    1 Pages

  9. SIM4 Series

    1 Pages

  10. SIM3 Series

    1 Pages

  11. SIM2 Series

    1 Pages

  12. SIF4 Series

    1 Pages

  13. SIF6 Series

    1 Pages

  14. SIF4 Series

    1 Pages

  15. SIF3 Series

    1 Pages

  16. SIS4 Series

    1 Pages

  17. SIS3 Series

    1 Pages

  18. SIS2 Series

    1 Pages

  19. SISF2 Series

    1 Pages

  20. SIR10 Series

    1 Pages

  21. SIR8 Series

    1 Pages

  22. SID4 Series

    1 Pages

  23. SIR 8 Series

    1 Pages

  24. SIR 6 Series

    1 Pages

  25. SIR 4 Series

    1 Pages

  26. SLR 4 Series

    1 Pages

  27. SIM 2 Series

    1 Pages

  28. SIF 6 Series

    1 Pages

  29. SIF 4 Series

    1 Pages

  30. SIF 3 Series

    1 Pages

  31. SIS 6 Series

    1 Pages

  32. SIS 4 Series

    1 Pages

  33. SIS 3 Series

    1 Pages

  34. SIS 2 Series

    1 Pages

Archived catalogs