Medium Voltage Program / Outdoor Head Current Transformer
Specifications:
  • Design: Cast-resin insulated, brown color.
  • Standards: Complies with VDE 0414, IEC 60044, ANSI C 57.13, BS 1675.
  • Insulation Class: B.
  • Thermal Short-time Current (Ith): 100 x In (max. 100 kA).
  • Rated Dynamic Current (Idyn): 2.5 x Ith (max. 125 kA).
  • Frequency: 50-60 Hz, other frequencies available on request.
  • Rated Insulation Voltage: Complies with standards.
  • Secondary Currents: 1A, 5A, other currents available on request.
  • Protection Degree: IP64 for secondary terminal box.
  • Special Features: Secondary switch-over available.
Technical Description:
  • The outdoor current transformer is designed for harsh environmental conditions and is maintenance-free.
  • It is only mountable in a vertical position.
  • The primary current is conducted through an internal bus bar, with secondary windings available for measurement and protection purposes, including optional test windings.
Technical Data (Table 1):
  • Types: IGHF 12 B 300, IGHF 24 B 300, IGHF 36 B 300.
  • Insulation Voltage (kV): 12/28/75, 24/50/125, 36/70/170.
  • Max. Primary Current (Ipn): 3000 A for all types.
  • Creepage Distance (mm): 409, 480, 1124 respectively.
  • Max. Number of Cores: 4, 5, 5 respectively.
  • Number of Rips: 3, 4, 10 respectively.
  • Weight (kg): 46, 48, 56 respectively.
Contact Information:
  • ELEQ Netherlands: P.O. Box 12, 8330 AA Steenwijk, Tukseweg 130, 8331 LH Steenwijk, The Netherlands. Phone: +31 (0)521 533 333, Fax: +31 (0)521 533 398.
  • ELEQ Germany: Siemensstraße 1, 50170 Kerpen-Sindorf, Germany. Phone: +49 (0) 2273 98 870, Fax: +49 (0) 2273 51 951.
  • Email: [email protected]
  • Website: www.eleq.com
See more

Catalog excerpts

Outdoor head current transformer-1

Mittelspannungsprogramm/ Freiluftkopfstromwandler Mdium Voltage Program/ Outdoor Head Current Transformer

 Open the catalog to page 1
Outdoor head current transformer-2

Mittelspannungsprogramm/ Mdium Voltage Program/ Freiluf tkopfstromwandler Outdoor Head Current Transformer Technische Beschreibung: Dec Fraluftkopfstfonrwandler ist im GieBharzvolfverguss, Das Harz ermoglicht eine Ajwendung unter Freiluft und erschwerten Umweltbedingungen. Der Wandler ist wartungsfrei und in vertikater Lage einbaubar Der Primrstrom wird mittels einem Primarbolzen durch den Wandler gef髹hrt Je nach Anforderungen krmen die Sekundrwicklungen fur Mess.- und / oder Schutzzwecke ausgef䠻hrt werden> Auf Wunsch auch mit Testwicklungen. Technical description; The st resin outdoor current...

 Open the catalog to page 2
Outdoor head current transformer-3

Tabellel / 7a6/e7 allgemeine Technische Daion teclmicalinformation Typ IGHF 12 IGHF 24 IGHF 36 Type B300 6300 B300 Isolaiionspegel |kV] Insolation voltage 12/28/75 24/50/125 36/70//170 Max. Ipn |A| Max. IpnfAj 3000 3000 3000 Kriechweg (mm] Cieepage distance 409 480 1124 Max. Aruahl det Keme Max number of cotes 4 ו 5 Anzahl der Rippen Numberofrips 3 10 Gewictit (kg) Weight 46 56 Mafcbild/ Dimensional drawing A B C D Srk <l=tnm«- Vuaril IGHF 12 3C0 300 3SD H» CD IGHF 24 300 9S5 545 10 4 IGHF 36 3C0 303 SG 692 10 10

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.