COMPACT-transducer EM800-
1Pages

{{requestButtons}}

Catalog excerpts

COMPACT-transducer EM800- - 1

EM800-Engels.xls table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:1.10pt "Arial", sans-serif; } .font1 { font:4.20pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial", sans-serif; } .font4 { font:8.00pt "Arial", sans-serif; } .font5 { font:9.00pt "Arial", sans-serif; } .font6 { font:10.00pt "Arial", sans-serif; } .font7 { font:11.00pt "Arial", sans-serif; } .font8 { font:12.00pt "Arial", sans-serif; } .font9 { font:17.00pt "Arial", sans-serif; } .font10 { font:25.00pt "Arial", sans-serif; } .font11 { font:5.00pt "Arial Black", sans-serif; } .font12 { font:10.00pt "Arial Black", sans-serif; } .font13 { font:6.00pt "Courier New", monospace; } .font14 { font:8.00pt "Courier New", monospace; } .font15 { font:6.00pt "Franklin Gothic Medium", sans-serif; } .font16 { font:7.00pt "Franklin Gothic Medium", sans-serif; } .font17 { font:5.00pt "Impact", sans-serif; } .font18 { font:4.00pt "Lucida Sans Unicode", sans-serif; } .font19 { font:10.00pt "Lucida Sans Unicode", sans-serif; } .font20 { font:7.00pt "Trebuchet MS", sans-serif; } EM800-C ^\ n ji i\ n ^\ -i- i COMPACT-transducer EM800-C Transducer for cos phi Transducer suitable for measurement of cos phi in 1 or multi phase systems with balanced or unbalanced loads. By using <xP-technology, allmost each thinkable output curve is possible. Input ► AC Voltage, nominal value from 58 up to 440V ► AC current, nominal 1A or 5A ► Sinusoidal or distorted Output ► Unipolair output and live-zero output ► Current or voltage output possible ► Single-, dual-, and tripple-slope output signals possible Aux. supply ► Normalised AC voltages from 58V up to 440V c S1 S2 l_ \ SI S2 P2 \ S1 / y, 1 m: I □cnr : mm □m m www EM800 AUX. SUPPLY OUTF Suitable wiring diagrams : S3 up to S9-4. More wiring diagrams on page 19 of our catalogue Order information You can use our product specification sheet PSBEEM800. You can find it on page 22 of our catalogue or via www.faget.com. hnput Output lAuxiliary supply Nominal voltage 58/100V...254/440V Output end value 1, 5, 10 or 20mA Voltage 100, 110, 230, 400, Nominal current 1A or 5A (6A max) live zero 20% of end value 440Vac Nominal frequency 45..50..60..65Hz load voltage 10V Power consumption <4VA on request 169Hz, 400Hz current limitation <30mA 1 iSafety 1 Range 0cap-1-0ind. Voltage output 1, 5 or 10V live zero 20% of end value Impulstest 5kV 1,2/50«s Overload 1,2xUn continue max. current load 10mA Insulation test 4kV 50Hz 1min. 2xUn / 10sec. voltage limitation <30V Housing protection 1,2xIn continue terminals IP20 50xIn / 1sec. Accuracy class housing IP40 Power consumption Class |0.5| EMC each current input 0,4VA Emission EN50081-1 each voltage input <500«A Ripple <0,4%pp Immunity EN50082-2 Response time Usage group III (IEC60688) 0-90% & 100-10% <250ms Pollution degree II (IEC60947-1) TS6EEM800-C AP110903

Open the catalog to page 1

All ELEQ catalogs and technical brochures

  1. LS-94

    1 Pages

  2. LS-84

    1 Pages

  3. LS-74

    1 Pages

  4. UAD16

    1 Pages

  5. UAD6

    1 Pages

  6. TQ40-C, 1A

    1 Pages

  7. TQ40-B, 1A

    1 Pages

  8. TQ30 Split

    1 Pages

  9. ELEQ GSA

    4 Pages

  10. RM60-D

    1 Pages

  11. IA60B31K

    1 Pages

  12. SB08

    1 Pages

  13. TQ-line

    1 Pages

  14. GSR

    4 Pages

  15. WSR

    1 Pages

  16. TQ50

    1 Pages

  17. VCT32

    1 Pages

  18. UAK

    1 Pages

  19. ZK4-M6/M8

    1 Pages

  20. RM27

    1 Pages

  21. TQ120

    1 Pages

  22. ELEQ WI-WIC

    1 Pages