1. Catalogs
  2. ELEQ
  3. Choke module for supressing ferro-resonance
video corpo

Choke module for supressing ferro-resonance

Choke module for supressing ferro-resonance

Product catalog summary
Technical Specification Overview

Introduction:
In three-phase current networks with an isolated neutral point using single-pole current transformers, ferro-resonance can occur. This phenomenon is caused by the interaction between the non-linear inductance of the single-pole current transformer in open-circuit operation and the earthing capacitance of the network. To prevent overheating and potential overvoltages, the transformer’s en-winding should be continuously vaporized.

Choke Module for Suppressing Ferro-resonance:
  • Ordering Specification: Steel
  • Dimensions: 222x190x229mm
  • Colour: Grey

Electrical Specifications:
  • Rated Voltage: 100V
  • Operating Voltage: 100…110V
  • Isolation Level: 0.72kV
  • Frequency: 50Hz (others available upon request)
  • Class of Insulation: E

Power Ratings:
  • Nominal Three Phase Current of Voltage Transformer: 2A, 4A, 6A, 9A, 10A, 15A
  • Total Power (P R total): 178W for 2A, 4A, 6A; 356W for 9A, 10A, 15A
  • Total Power (P D total): 147W for 2A, 4A, 6A; 295W for 9A, 10A, 15A
  • Power Capacity: 800VA for BE2, BE4, BE6, BE9; 1200VA for BE10, BE15

Connection Scheme:
Includes saturable coil and resistance BE with various voltage configurations (U, V, u, v, e, n).
See more

Catalog excerpts

Choke module for supressing ferro-resonance-1

Choke module for suppressing ferro-resonance In three phase current networks with isolated neutral point which use single-pole current transformers, ferro-resonance may occur. These resonances are generated by the concur of single-pole current transformer's non-linear inductance of open-circuit operation and the earthing capacitance of the network. In order to protect the single-pole current transformer from overheating and to avoid possible overvoltages, the en-winding of the transformer should be constantly vaporised. Connection Scheme u ɉ v w w w Technical specification Rated voltage 100V Operating voltage 100...110V Isolation level 0,72kV Frequency 50Hz (others upon request) Class of insulation LU Case Steel Dimensions 222x190x229mm Colour Grey V\i I I e ll/l/L n resistance BE saturable coil "(V)" Ordering specification Type Nominal three phase current of voltage transformer P R total P D total 100V 110V BE2 2A 147W 178W 800VA BE4 4A 147W 178W 800VA BE6 6A 147W 178W 800VA BE9 9A 295W 356W 800VA BE10 10A 295W 356W 1200VA BE15 15A 295W 356W 1200VA ɮl ELEQ* develops, produces and markgts FAGET ,ind KWK" WWW.ELEO.CQM