1. Catalogs
  2. Elementar
  3. rapid CS cube

rapid CS cube

rapid CS cube

rapid CS cube

Product catalog summary
Introduction
Elementar has developed a dedicated C/S analyzer, the rapid CS cube, designed for high-performance analysis of sulfur and carbon in various samples such as coals, soils, and organic materials. This is crucial for environmental cleanliness.

Specifications
The analyzer operates by automatically feeding samples into a 1200°C catalytic combustion chamber in pure oxygen. Sulfur is converted to SO2 and measured using an NDIR detector, while carbon is oxidized to CO2 and similarly measured. The system calculates sulfur concentration from the IR signal and sample weight.

Features
  • Automatic Analysis: Integrated autosampler for up to 120 samples.
  • Full Sulfur Recovery: Quartz tube combustion ensures 100% conversion of sulfur to SO2.
  • NDIR Detector: Utilizes a gas absorption chamber for noise reduction and interference-free detection.
  • Closed System: Ensures high sensitivity with less than 1 ppm detection for sulfur and carbon.
  • Microelectronics: Digital control allows for remote operation and diagnostics.
  • Software: Windows-based software for full control and real-time monitoring.

Applications
The rapid CS cube can analyze a wide range of samples, from coal to fine chemicals and plant material, with accurate results even without similar standards. Minimal sample preparation is required.

Maintenance and Cost
  • Easy Maintenance: Ash residue removal is quick, and weekly maintenance involves replacing the water scrubber.
  • Low Cost: Uses inexpensive operational supplies and has a long-lasting quartz combustion tube.

Installation Requirements
Requires minimal laboratory space and standard electrical and gas connections.

Analysis Method and Standards
  • Method: High-temperature combustion and conversion of sulfur and carbon measured with NDIR detector.
  • Standards: Complies with ISO 15178:2000, DIN 51724-3, and DIN 38409.
  • Safety: CE label and compliance with EN 61010-1 and EMV directives.

Technical Specifications
  • Temperature: Furnace at 1200°C, temporarily reaching 1800°C.
  • Measuring Range: 0–100% for sulfur and carbon.
  • Detection Limit: Less than 1 ppm for sulfur and carbon.
  • Precision: Less than 1% RSD.
  • Analysis Time: Approximately 5 minutes.
  • Sample Weight: Up to 1 g for soil or 100 mg for organic material.
  • Dimensions: 48 × 55 × 55 cm, approximately 60 kg.
See more

Catalog excerpts

rapid CS cube-1

Elemental analysis for a better environment Elementar holds the world’s longest tradition in the analysis of the “organic” elements CHNS and O. Today we are all aiming for a cleaner environment which requires more and more the analysis of sulfur and carbon, e.g. in coals, soils and organic samples. Therefore with our special experience a dedicated C/S analyzer has been developed which combines the highest analytical performance with high automatic sample throughput. The concept is straight. Samples are wrapped and automatically fed to a 1200 °C catalytic combustion in pure oxygen. Contained sulfur is converted to SO2 which is measured by means of an NDIR-detector. Carbon compounds are oxidized to CO 2 which is again measured via IR detection. From IR-signal and sample weight the computer calculates the sulfur concentration Automatic analysis for solids and liquids The rapid CS cube has an integrated autosampler which automatically feeds up to 60 or even 120 samples. Solids are wrapped in tin foil or paper and liquids sealed in tin capsules. Full sulfur recovery Combustion takes place in a quartz tube which has advantages compared to ceramics for lower S-concentrations. A permanent temperature near 1200°C and temporarily near 1800°C results in 100 % conversion of S into SO2 even in case of BaSO 4. Large range special NDIR detector The NDIR detector utilizes a gas absorption chamber instead of the more typical solid detector. This results in reduction of noise and an interference free detection. Detection of up to 20 mg absolute sulfur or 40 mg absolute carbon, with a single absorption cell and one detector range is achieved. Closed system for high analytical sensitivity The entire analytical operation takes place in a closed system with no inuence from the ambient atmosphere. This also serves for the highest sensitivity of less than 1 ppm S or C.

 Open the catalog to page 1
rapid CS cube-2

rapid CS cube State of the art microelectronics The rapid CS cube has full digital control of all functions. This results in completely new possibilities of automatic operation as well as remote control and diagnosis over the internet. High class software The Windows® based software allows full instrument control from a PC. Continuous monitoring of real time conditions of the analyzer in both numerical and graphical form. Data safety and validity can be assured with the available 21 CFR Part 11 option. Large variety of applications The rapid CS cube is able to analyze e.g. 400 mg of coal, less...

 Open the catalog to page 2

All Elementar catalogs and technical brochures

  1. trace SN cube

    4  Pages

  2. rapid CS cube

    4  Pages

  3. VARIO ISOTOPE

    4  Pages

  4. ferro.lyte®

    4  Pages

  5. ionOS

    8  Pages

  6. iso FLOW

    4  Pages

  7. UNICUBE

    4  Pages

  8. AromavisION

    4  Pages

  9. soli TOC

    4  Pages

  10. vario TOC

    4  Pages

  11. vario PYRO

    4  Pages

  12. GC5

    4  Pages

  13. PetrovisION

    3  Pages

  14. vario EL cube

    4  Pages

  15. Trace SN

    4  Pages

  16. rapid OXY

    4  Pages

  17. rapid MICRO N

    4  Pages

  18. Rapid CS

    4  Pages

  19. vario MACRO

    4  Pages

  20. vario MAX

    4  Pages

  21. GeovisION

    3  Pages

  22. EnvirovisION

    3  Pages

  23. AnthrovisION

    3  Pages

  24. EcovisION

    3  Pages

  25. BiovisION

    3  Pages

  26. vario EL cube

    2  Pages

  27. trace SN cube

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.