Nandralone is an anabolic androgenic steroid banned by the World Anti-Doping Agency due to its performance-enhancing effects. Its main metabolite, 19-Norandrosterone (19-NA), can be analyzed using GC-C-IRMS to differentiate between endogenous and exogenous sources. This is particularly challenging in male athletes due to low concentration levels.

Objective
This bulletin presents the δ13C analysis of 19-NA using the AnthrovisION GC-C-IRMS system across a wide range of sample concentrations. It demonstrates the system's limit of isotope quantification and linearity performance.

Methodology
The analysis was conducted using pure synthetic 19-NA compounds injected as a single compound into the GC to prevent co-elution or contamination issues.

Instrument Details
  • Instrument: AnthrovisION
  • Mode: C
  • Sample: Nandralone / 19-NA


Results
The GC-C-IRMS system achieved a precision of 0.37‰ at a sample concentration of 2.4 ng or 200 pmols of carbon on the column, indicating high sensitivity for this steroid analysis.

Data Summary
CONC [ppm]INJ. VOL. [µl]COMPOUND ON COLUMN [ng]CARBON ON COLUMN [pmol]PEAK HEIGHT [nA]δ13C [‰]SENSITIVITY [ng C/nA]
12.522519.61633-29.82 to -30.194.1 to 4.6
12.5112.59.8817-30.26 to -30.763.2 to 3.6
6.2516.254.9408-29.59 to -30.763.5 to 3.8
6.250.53.1252.4200-29.84 to -30.513.7 to 3.9


Conclusion
The AnthrovisION GC-C-IRMS system provides high sensitivity and precision for the analysis of 19-NA, making it suitable for distinguishing between endogenous and exogenous sources of this steroid.
See more

Catalog excerpts

Analysis of 19-Norandrosterone by GC-C-IRMS-1

DATA BULLETIN Analysis of 19-Norandrosterone by GC-C-IRMS Nandralone is an anabolic androgenic steroid which is known to have performance enhancing characteristics and so has been banned by the World Anti-Doping Agency. 19-Norandrosterone (19-NA) is the main metabolite of Nandralone and GC-C-IRMS analysis of the δ13C ratio of this compound is able to distinguish between endogenous and exogenous sources. Because of the differences in physiology in male and female athletes it is common that 19-NA concentrations in males can be at INSTRUMENT: AnthrovisION DETAILS: mode: C sample: Nandralone / 19-NA challengingly low levels. This Data Bulletin presents δ13C analysis of 19-NA using the AnthrovisION GC-C-IRMS over a large range of sample concentrations. The limit of isotope quantification for this analysis and the linearity performance of the system is demonstrated. The 19-NA samples were pure synthetic compounds and were analyzed as a single compound injection in to the GC to avoid any issues with co-elution or contamination. CONC [ppm] Over a wide range of sample concentrations, the GC-C-IRMS system achieved a precision of 0.37‰ down to a sample concentration of 2.4 ng or 200 pmols of carbon on column which represents very high sensitivity for this analysis of a challenging steroid compound. Elementar Analysensysteme GmbH Elementar-Straße 1 63505 Langenselbold (Germany) phone: +49 (0) 6184 9393-0 [email protected] | www.element

 Open the catalog to page 1

All Elementar catalogs and technical brochures

  1. trace SN cube

    4  Pages

  2. rapid CS cube

    4  Pages

  3. VARIO ISOTOPE

    4  Pages

  4. ferro.lyte®

    4  Pages

  5. ionOS

    8  Pages

  6. iso FLOW

    4  Pages

  7. UNICUBE

    4  Pages

  8. AromavisION

    4  Pages

  9. soli TOC

    4  Pages

  10. vario TOC

    4  Pages

  11. vario PYRO

    4  Pages

  12. GC5

    4  Pages

  13. PetrovisION

    3  Pages

  14. vario EL cube

    4  Pages

  15. Trace SN

    4  Pages

  16. rapid OXY

    4  Pages

  17. rapid MICRO N

    4  Pages

  18. Rapid CS

    4  Pages

  19. vario MACRO

    4  Pages

  20. vario MAX

    4  Pages

  21. GeovisION

    3  Pages

  22. EnvirovisION

    3  Pages

  23. AnthrovisION

    3  Pages

  24. EcovisION

    3  Pages

  25. BiovisION

    3  Pages

  26. vario EL cube

    2  Pages

  27. trace SN cube

    2  Pages

Archived catalogs

  1. rapid CS cube

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.