SZM 16 - 16 Reports and relay output per each report
4Pages

{{requestButtons}}

Catalog excerpts

SZM 16 - 16 Reports and relay output per each report - 1

Panel mounting Standard fault annunciator SZM 16 - 16 Reports and relay output per each report › Compact module for 16 alarms 24 V ... 250 V AC/DC › First-up / New value as alarm sequence; 1 or 2 frequency flashlight › 16 relay contacts parallel to in- or output triggering › Potential separation of all circuits by optocouplers › Sealed front console, protection class IP 54 › Functions programmable per dip switch › Pluggable screw terminals › Slide-in window pockets for an individual marking of LEDs and buttons

Open the catalog to page 1
SZM 16 - 16 Reports and relay output per each report - 2

SZm 16 - 16 reports and relay output per each report General system description An as compact as possible and universally usable fault annunciator is needed especially for use in high voltage switching areas. The battery- supported supply voltage usually is 110 or 220 V DC and is directly connectable. The fault indication is done by 16 red LED‘s built in the front panel (other colours on request) with 1-frequency flashlight (as option 2-frequency). The LED‘s can be marked via slide-in labels with 40 mm textlength and 3,5 mm height for each channel. The fault annunciator has 2 collective...

Open the catalog to page 2
SZM 16 - 16 Reports and relay output per each report - 3

panel mounting standard fault annunciator Standard design • 1-frequency flashlight • All switches are in OFF position • Triggering of relays outputs is done parrallel to inputs • Relay contacts are designed as NO-contact Options • 2-frequency flashlight -- fast flashlight / steady light / slow flashlight • ∑2 is replaced by a second horn priority - input 1 ... 8 assigned to horn H1 input 9 ... 16 assigned to horn H2 • All relay contacts designed as NC-contacts • Alternative use of collective reports - Collective report for input 1 ... 16 Live-Contact (NC) • BSV-Soft - Label patterns for...

Open the catalog to page 3
SZM 16 - 16 Reports and relay output per each report - 4

SZm 16 - 16 reports and relay output per each report Flashing frequency Fast flashing Slow flashing Load on relay contacts Mechanical data Housing Front frame Panel cut-off Installation Weight Ambient conditions Ambient temperature Storage temperature Protection class front Protection class back Terminals Wire cross-section rigid or flexible Without wire sleeves With wire sleeves Humidity approx. 1 Hz approx. 0.25 Hz 24 ... 250 V AC 2 A; 110 V DC 0.5 A; 220 V DC 0.3 A MBS ( fibre reinforced Noryl ) 72 x 144 mm; max. installation depth 158 mm 66 x 138 + 1 mm aribitrary approx. 1.1 kg -20 °C...

Open the catalog to page 4