MKPg™ THREE-PHASE POWER CAPACITORS: High End For The Heart Of Your PFC Installation The construction of reliable equipment for power factor correction requires not only your excellent experience, but also top-class components. No compromise in quality and safety should be permitted when it comes to the key part of your PFC equipment. Being Germany's largest manufacturer of power capacitors, ELECTRONICON manufactures all components with highest care and expertise and is your best choice for capacitors and detuning reactors. The dry-type phase shifters of our renowned MKPg™-series are environ- mentally friendly, compact, and very convenient to handle. They contain no liquids and are filled with a neutral, inert gas entirely harmless to environment. When disposing of the capacitors, no liquids or toxic gasses By using the best low-loss, self-healing polypropylene films and sophisti- cated manufacturing techniques such as high-vacuum drying and special coating patterns, MKPg™ provide long service life with constant capa- citance and high switching stability. As a matter of course, all our power capacitors are provided with BAM™ (overpressure break-action mechanism] as standard, for safe mode of failure. Three-phase MKPg™ capacitors contain three delta-switched capacitor elements of short height and large diameter. This design substantially reduces inherent power losses and improves their current strength as compared with the slim, tall capacitors of many competitors. Dur capacitors may be mounted in any desired position. Should leakage occur, the leaking gas would escape into the atmosphere causing no undesirable effects to the adjacent equipment, e.g. damage, pollution, Dur original CAPAGBIP™ terminals with their options K, L, and M gua- rantee optimum sealing of the capacitors, and offer convenient connection of cables up to 50mm2. A special spring system guarantees reliable and durable operation of the clamp. They are rated IP20, i. e. protected against accidental finger contact with live parts. Designs L and M also permit the direct connection of discharge reactors and discharge resistor modules, as well as easy parallel connection of additional capacitors. GENERAL TECHNICAL DATA
Open the catalog to page 1MKPg™ GAS-FILLED POWER CAPACITORS: Best for Mains and Nature Ease of Assembly with High Degree of Protection terminal design cable cross section fastening torgue discharge resistors separate module separate module Root mean square of the max permissible value of sinusoidal the rated voltage must not be exceeded even in cases of malfunction. Bear in mind that capacitors in detuned equip- ment are exposed to a higher voltage than that of the rated mains voltage; this is caused reactor and capacitor in series Consequently, capacitors used with reactors must have a vol- tage rating higher than...
Open the catalog to page 2FK-Dr™ THREE-PHASE DETUNING REACTORS - Protect your Capacitors from Resonances Contemporary practice of power factor correction has become unthinkable without the use of series reactors for blocking resonances with mains inductances and overloads. As a side effect, the overall level of harmonic distortion is also reduced to a considerable extent. We manufacture our three phase filter reactors of specially selected transformer sheets and aluminium band. Alternatively, copper windings are available on request. Unlike many low-end products, our aluminium reactors are connected through copper...
Open the catalog to page 3The Perfect Match for your PFC System Reactors for standard capacitors (Non-adjusted rating): A ..nan-adjusted reactor" is matched to a power capacitor with standard rating at system voltage. Mind that with the increased output of kvar due to voltage rise inside the resonance circuit, more power output is installed than actually required by the customer.
Open the catalog to page 4IMPORTANT REMARKS ELECTRONICON will not indemnify or be responsible for any kind of damages to persons or property due to the improper application of any capacitors or reactors purchased from ELECTRONICON or its distributors. The capacitors and reactors should only be used for the application Mind that electrical or mechanical misapplication of capacitors and reactors can become hazardous. Misapplied capacitors can explode or catch fire and cause bodily injury or property damage due to the expulsion of material or metal fragments. Please consult the detailed instructions for mounting and...
Open the catalog to page 5All ELECTRONICON Kondensatoren catalogs and technical brochures
-
Capacitors for power electronics
35 Pages
-
PEC Application notes
52 Pages
-
E62-3PH AC FILTER
24 Pages
-
E62 AC/DC
40 Pages
-
E51 AC/DC
24 Pages
-
E63 DC
16 Pages
-
E61 DC
34 Pages
-
E56 DC / E59 AC/DC
32 Pages
-
E50.U SR17
3 Pages
-
FKD-MV™
16 Pages
-
E90 MSD™
32 Pages
-
280 MKP UHD
2 Pages
-
276 MKP(D) oil filled
2 Pages
-
275 MKPg Heavy Duty 400-440V
2 Pages
-
FK-DR CU/ALU
8 Pages
-
ELR™ Line Reactors
1 Pages
Archived catalogs
-
ELR Line Reactors (English)
1 Pages
-
E93 DSC data chart (English)
2 Pages
-
E61 Catalogue
6 Pages
-
E51 E53 E55 Catalogue
16 Pages
-
Power Factor Controller
5 Pages
-
Discharge Reactor ELDr
1 Pages
-
Detuned Reactors FKDr
16 Pages