Catalog excerpts
DC CAPACITORS WITH OVERPRESSURE PROTECTION DC KONDENSATOREN MIT ÜBERDRUCKSICHERUNG
Open the catalog to page 1The special kind of films and coatings used in our E63-capacitors makes them interesting particularly for applications with high rms currents, e.g. as smoothing or supporting capacitors in buffer storage circuits. Filled with liquid resin, these capacitors have a high specific ratio of capacitance to volume. At the same time, they are extremely overvoltage proof. Very good self-healing characteristics and the integrated overpressure protection (break-action mechanism) ensure safe operation and controlled disconnection in the event of overload or failure at the end of operating life. Die...
Open the catalog to page 3Design drawings see on pages 9-14_MaBbilder siehe auf den Seiten 9-14 Other values and dimensions available on request_Andere Werte und Abmessungen auf Anfrage erhaltlich
Open the catalog to page 4Design drawings see on pages 9-14_MaBbilder siehe auf den Seiten 9-14 Other values and dimensions available on request_Andere Werte und Abmessungen auf Anfrage erhaltlich
Open the catalog to page 5Design drawings see on pages 9-14_MaBbilder siehe auf den Seiten 9-14 Other values and dimensions available on request_Andere Werte und Abmessungen auf Anfrage erhaltlich
Open the catalog to page 6KONDENSATOREN MIT EINEM GEHAUSEDURCHMESSER VON 45...55 mm
Open the catalog to page 7KONDENSATOREN MIT EINEM GEHAUSEDURCHMESSER VON 75...136 mm
Open the catalog to page 8KONDENSATOREN MIT EINEM GEHAUSEDURCHMESSER VON 75...136 mm
Open the catalog to page 9KONDENSATOREN MIT EINEM GEHAUSEDURCHMESSER VON 50/55/65 mm
Open the catalog to page 10CAPACITORS WITH A CAN DIAMETER OF 60...136 mm KONDENSATOREN MIT EINEM GEHAUSEDURCHMESSER VON 60...136 mm 1| For design K1, L1 and M1 the central screw has no contact_Bei den Ausfiihrungen K1, L1 und M1 hat die mittlere Klemme keinen Kontakt
Open the catalog to page 12Important Remarks Wichtige Hinweise Safety ELECTRONICON will not indemnify or be responsible for any kind of damages to persons or property due to the improper application of any capacitors purchased from ELECTRONICON or its distributors. The capacitors should only be used for the application intended. Sicherheit ELECTRONICON übernimmt keine Verantwortung oder Haftung für jegliche Schäden an Personen oder Eigentum, welche aus der unsachgemäßen Anwendung von bei ELECTRONICON oder seinen Distributoren erworbenen Kondensatoren herrührt. Die Kondensatoren dürfen ausschließlich für ihren...
Open the catalog to page 13Failure Rate The failure probability of a component is a statistical value which is described by a log-normal distribution: Ausfallrate Die Ausfallwahrscheinlichkeit eines Bauelements ist eine statistische Größe, die mit Hilfe einer Normalverteilung beschrieben wird. Es gilt: N = number of functional components after period t Anzahl der nach der Zeit t intakten Bauelemente No = total number of components at time t = 0 Gesamtzahl der Bauelemente zum Zeitpunkt t = 0 = failure rate Ausfallrate is the failure rate, which alternatively is also stated as the so-called FITrate (FIT = Failures In...
Open the catalog to page 14Functioning of the BAMTM (Break Action Mechanism) In the event of overvoltage or thermal overload or ageing at the end of the capacitor’s useful service life, an increasing number of selfhealing breakdowns may cause rising pressure inside the capacitor. To prevent it from bursting, the capacitor is fitted with an obligatory „break action mechanism“ (BAMTM). The BAMTM is based on an attenuated spot at one of the connecting wires inside the capacitor. With rising pressure the case begins to expand, mainly by opening the folded crimp and pushing the lid upwards. As a result, the prepared...
Open the catalog to page 15Warning: It has to be noted that this safety system can act properly only within the permitted limits of loads and overloads. The simple presence of a safety mechanism does not mean that catastrophic failures are completely impossible. Strong overvoltages, permanent external heat, and heavy current overload, e.g. during harmonic resonances may cause sudden, uncontrollable rise of temperature and pressure inside the can which may not leave sufficient time for the BAMTM to act properly, and result in explosion and fire. For more detailed information, please order our long-version catalogue...
Open the catalog to page 16All ELECTRONICON Kondensatoren catalogs and technical brochures
-
Capacitors for power electronics
35 Pages
-
PEC Application notes
52 Pages
-
E62-3PH AC FILTER
24 Pages
-
E62 AC/DC
40 Pages
-
E51 AC/DC
24 Pages
-
E61 DC
34 Pages
-
E56 DC / E59 AC/DC
32 Pages
-
E50.U SR17
3 Pages
-
FKD-MV™
16 Pages
-
E90 MSD™
32 Pages
-
280 MKP UHD
2 Pages
-
276 MKP(D) oil filled
2 Pages
-
275 MKPg Heavy Duty 400-440V
2 Pages
-
FK-DR CU/ALU
8 Pages
-
ELR™ Line Reactors
1 Pages
Archived catalogs
-
ELR Line Reactors (English)
1 Pages
-
E93 DSC data chart (English)
2 Pages
-
E61 Catalogue
6 Pages
-
E51 E53 E55 Catalogue
16 Pages
-
Power Factor Controller
5 Pages
-
Discharge Reactor ELDr
1 Pages
-
Detuned Reactors FKDr