Catalog excerpts
E01/E02/E05/E06 AC CAPACITORS FOR PARALLEL COMPENSATION IN FLUORESCENT LIGHTING WECHSELSPANNUNGSKONDENSATOREN FUR DIE PARALLELKOMPENSATION IN FLUORESZENZLEUCHEN
Open the catalog to page 1Capacitors for Fluorescent and Gas Discharge Lamps Compwsating capacitors in HKP-tedinology art AC capaotws teigned far hriliBt cwrucbon ol thi parti faclor of Uanstamers and majiwtic ballasts in dsdtarge bnps (ej. fluorescent lamps. halogen and mtal «pour Laraps. high-pressure mpcury voposr lafrɧs. sodium lamps] in mains wth a fr*qu«ncy of SO « 60 * Thts *Uws for an improvffunt of tto lununaiy s pcwer factor to cos <f * 0.9. The correction of The pemr factoi ol fluorescent tjmps an be effected in &call*d indrnduat andfaf group condensation AU cfacitors bsted in thts catatope are...
Open the catalog to page 3MOUNTING AND OPERATING INSTRUCTIONS VORSCHRIFTEN ZU BETRIEB UND EINBAU ZVGI: Mounting and Operating Instructions Safe opration of the capacitors can be expected only if ail electrical and thermal specifications as stated on the label, in the data sheets or catalogues and the following instructions are strictly observed. Vorschriften zu Betrieb und Einbau Grundsatzlich ist ein sicherer Betrieb der Kondensatoren nur ge-wahrleistet, wenn die elektrischen und thermischen Grenzwerte gemaB Typenschild, Datenblatt bzw. Katalog und die nachfolgenden Anweisungen eingehalten werden....
Open the catalog to page 10Connection and fixation Anschluss und Befestigung The capacitors are fixed by an M8 base mounting stud. For lighting capacitors Die Befestigung erfolgt mit M8 Bodenschraube. Fur Leuchtkondensatoren in plastic can an alternative fixation with lateral clip is available. im Kunststoffbecher sin aufierdem Varianten mit seitlicher Befestigung (Seitenclip") erhaltlich. The following kinds of connection are available as standard. Please see the Im Standardsortiment sind die folgenden Anschlussarten verfugbar Details data charts on pages 6 - 8 for details on each type series. zu den einzelnen...
Open the catalog to page 11Piro I narl Brandiast E AU outer parts of our capacitors are made of flame-retardant material. However it must be considered in the application that the filling resins, oils, and winding elements are flammable. The energy content of an MKP capacitor is approx. 40 MJ/kg. Alle Kondensatoren sind ufierlich aus flammhemmenden Materialien ge-fertigt. Vergussstoffe, Ole und das Wickelmaterial sind jedoch brennbar. Dem ist beim Einbau Rechnung zu tragen. Die Brandlast eines MKP-Kon-densators betrgt ca. 40 MJ/kg. o o o o RoHS Compliance Einhaltung der RoHS-Richtlinie ✓ RoHS I2002/95/EC According to...
Open the catalog to page 12Important Remarks Wichtige Hinweise Safety ELECTRONICON will not indemnify or be responsible for any kind of damages to persons or property due to the improper application of any capacitors pur-chased from ELECTRONICON or its distributors. The capacitors should only be used for the application intended. Mind that electrical or mechanical misapplication of capacitors can become hazardous. Misapplied capacitors can explode or catch fire and cause bodily injury or property damage due to the expulsion of material or metal fragments. Please consult the detailed instructions for mounting and...
Open the catalog to page 13Important: ! Overvoltage has a dramatic effect on service Life and risk of faillie: on average, a 10% increase of the operating voltage halves the expected life-time, or in other words, doubles the failure rate of a capacitor (compare "FIT rate" in our brochure "Application Notes"). ! Subject to inductive components within the capacitor circuit, motor run capacitors and capacitors connected in series with luminaire ballasts, are exposed to voltages which permanently exceed the rated mains voltage. This, and the tolerances of all elements in the circuit as well as their drift due to ageing...
Open the catalog to page 14spcial compound Spezialverbindunc thermal l驩ment Thermoelement Temprature Fuse (type A capacitors] For lighting capacitors without overpressure protection, ELECTRONICON offers a thermal fuse which is integrated in the capacitor core and which responds to overtemperatures caused by electrical or thermal overload. The fuse element within the body melts when a critical temperature is re-ached. It melts into small open globules which are completely insulated from each other not only by the distance but also by a special insulating compound which appears at the point of meltdown. The thermal...
Open the catalog to page 15In its Suidelines for the Prmntio ot Damage Caused lm*fi%$4the Association ot Getman Pioperly bsvers - VdS - tanmfc: "Capacilors vrrthout oveiprtssure break*action mechanism must be encapsulateri in li WWJHI* m⫩tal caw which prevents the gntion of inflammable ma* Only cepacirxs wiOi break-action mechanism aresi* table for lis* in sen-sitire envirment ta casa ot doubt regarding th* character ot the ambtenl conditions wcapacrtwswitti break-actio« Mechanism shouldbeused. Dm Vertet4 dtr deutschefi Sacܠwf»c*im*i sagt in seiner RichtlM» mSchadenvtrhtung duich eiektrache LeucMen smngemafl. Bei...
Open the catalog to page 16All ELECTRONICON Kondensatoren catalogs and technical brochures
-
Capacitors for power electronics
35 Pages
-
PEC Application notes
52 Pages
-
E62-3PH AC FILTER
24 Pages
-
E62 AC/DC
40 Pages
-
E51 AC/DC
24 Pages
-
E63 DC
16 Pages
-
E61 DC
34 Pages
-
E56 DC / E59 AC/DC
32 Pages
-
E50.U SR17
3 Pages
-
FKD-MV™
16 Pages
-
E90 MSD™
32 Pages
-
280 MKP UHD
2 Pages
-
276 MKP(D) oil filled
2 Pages
-
275 MKPg Heavy Duty 400-440V
2 Pages
-
FK-DR CU/ALU
8 Pages
-
ELR™ Line Reactors
1 Pages
Archived catalogs
-
ELR Line Reactors (English)
1 Pages
-
E93 DSC data chart (English)
2 Pages
-
E61 Catalogue
6 Pages
-
E51 E53 E55 Catalogue
16 Pages
-
Power Factor Controller
5 Pages
-
Discharge Reactor ELDr
1 Pages
-
Detuned Reactors FKDr
16 Pages