EM-M22I/A/mA converter

EM-M22I/A/mA converter

Product catalog summary
Overview: The EM-M22 is a device designed for measuring AC current using a current transformer and converting it into a current signal. It measures AC current as TrueRMS, providing RMS output even for non-sinusoidal signals. The device outputs a 4...20mA signal and can also function as a 1...5V signal transducer.
Specifications:
  • Input Ranges: 5A and 1A, standard current transformer output values.
  • Output Signal: 4...20mA and 1...5V.
  • Supply Voltage: 12...32 Vdc.
  • Input Impedance: 0.05 ohm for 5A range, 0.27 ohm for 1A range.
  • Linearity Error: Less than 0.5% for sinusoidal signals.
  • Thermal Drift: Less than 200ppm/°C.
  • Settling Time: 0.3 seconds.
  • Frequency Range: 45...1000Hz.
  • Loop Resistance: 0-700 ohm at 24V supply.
  • Operating Ambient Temperature: 0...50°C.
Features:
  • Measures TrueRMS.
  • Settable gain.
  • Over current and reverse current protection.
  • Easy to connect and rail mountable.
Design and Protection: The EM-M22 is designed to be efficiently protected from faulty connections and voltage peaks. It is powered by the current loop, requiring no additional power supply.
Installation: The device is rail mountable with a housing width of 25mm. It is recommended to use a loop resistance of less than 800 ohms.
Contact Information: ELECTROMEN Oy, Vähäheikkiläntie 56B, 20810 Turku, Finland. Tel. +358-2-4693050, Fax. +358-2-4693052.
See more

Catalog excerpts

EM-M22I/A/mA converter-1

EM-M22 TRMS 5A / 1A TO 4...20mA FEATURES • Measures TrueRMS • Input ranges 5A and 1A • Output 4...20mA and 1...5V • Settable gain • Over current protected • Reverse current protected • Easy to connect • Rail mountable EM-M22 is designed for measuring AC current. The device was designed to work with current transformer and as a converter to current signal. The AC current is measured as TrueRMS, in other words the device gives RMS output also from other than sinus shaped signals. The measured current is converted into 4...20mA signal. There are two measuring ranges, 5A and 1A, which are standard current transformer output values. The device takes it’s supply power from current loop and requires no other power supply. The device can also be used as 1...5V signal transducer according to the schematic down low. EM-M22 is efficiently protected from faulty connections and voltage peaks. 79mm 25mm TECHNICAL DATA Supply Measuring range Input impedance Output signal Linearity error Thermal drift Settling time Frequency range Loop resistance Oper. ambient temp. 12...32 Vdc 5AC RMS 20A peak 1AC RMS 4A peak 0.05 ohm / 5A 0.27 ohm / 1A 4...20mA / 1...5V <0.5% (sin) <200ppm/°C 0.3s 45...1000Hz 0-700 ohm ( 24V ) 0...50°C EM-M22 4...20mA OUTPUT 12-32V 4 1 5A in Rin at 5A range = 0.05 ohm Rin at 1A range = 0.27 ohm 6 RL 86mm 1...5V OUTPUT 15-32V 4 RL= 0-700 ohm at 24V supply 1...5V U-out 5 6 ELECTROMEN Oy, Turku, Finland DIN-MOUNTING RAIL WIDTH OF THE HOUSING IS 25MM 1...5V Uout t 12...32V 4 15...32V LARGEST POSSIBLE MEAS. RESISTOR AS A FUNCTION OF OPER. VOLTAGE VCC/V 4 30 TRMS-meas 1AC-IN I-out 5 4...20mA 3 COM. t 1 2 1A in CURRENT TRANSFORMER 4...20mA CURRENT LOOP 5AC-IN AC-CURRENT to 4...20mA CONVERTER 2 i = 4...20mA 0.27 24 0.05 mA-conv. 5 3 LOOP RES. MEAS 5 Uout 1...5V 18 COMMON RL 250 ohm. 6 6 Rin >250k GAIN 12 <100 RL/ohm ELECTROMEN Oy Vähäheikkiläntie 56B, 20810 Turku, FINLAND <400 <700 <1000 RECOMMENDATION <800 ohm Tel. +358-2-4693050 Fax. +358-2-4693052

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.