Reliable Products Trustworthy People Tachometers, Counters & Displays Displays rate, time-in-process, ratio, sum, difference, or draw Optional relay outputs and/or 4-20 mA analog output Completely field programmable Full diagnostic functions Setpoint and start delay functions 3 programmable inputs 3 programmable transistor setpoint outputs Keypad lockout Optional explosion proof enclosure Optional NEMA 4X enclosure kit 115, 230 VAC (50-60 Hz) and 10-30 VDC power options The TR5000 is a full logic control process ratemeter that can display up to three separate values of rate and compare them to programmable setpoints. Rates A and B can be programmed by the user for speed or time in process. Rate C allows the user to display a relationship between rates A and B. This can be a Ratio (A/B), Sum (A+B), Difference (AB), or Draw (A-B)/B. A ratio is typically used in blending and mixing applications. The sum and difference are commonly used when the operator needs to display the combined output of two separate but related processes. Draw is commonly used in web handling systems, such as plastic or wire, to indicate the thickness or stretch of the material being processed. A shaft-mounted pulser disc or pulser wrap generates an alternating magnetic field that is picked up be the sensing head. The sensor transmits the speed as a digital pulse frequency to the TR5000 via a three conductor shielded cable. The TR5000 then compares this frequency signal to its programming and determines the appropriate setpoint output state and display value. The TR5000 features three transistor outputs that can be set within any of the three rates A, B, or C. These outputs can be programmed to latch (requiring a manual reset), or stay active only when the setpoint condition is present. • 4-20 mA output can be programmed to represent three rates: A, B, or C. The 4-20 mA output can be scaled to reflect any area of the range, including operations requiring an inverse output • Up to three programmable relay contact outputs, rated 250 VAC, 30 VDC at 5 Amps resistive load Status LEDs give entry mode and operation status Display window Used to change or examine program Used for programming optional analog output and displays in reverse direction (quadrature input required) Used to test the TR5000 6111 BLUE CIRCLE DRIVE
Open the catalog to page 1Reliable Products Trustworthy People Input Power Voltage Tachometers, Counters & Displays Input Power Analog Output Part Number Optional Voltages 115 VAC, 6 VA @ 50/60 Hz, 1/16 Amp, requires external fuse 230 VAC, 10-30 VDC Sensor Input Switch Selectable 2,200 Ohm pull up to 12 VDC, 2.5 Volt trigger level 2,200 Ohm pull down, 2.5 Volt trigger level Logic Level 2.5 Volt trigger level Magnetic Pick-up 150 mV peak-to-peak minimum signal, 50 mV trigger level Sensor Supply External Control I/O Standard Inputs 3 programmable switch inputs Standard Setpoint Outputs 3 programmable, open collector transistors,...
Open the catalog to page 212 Pages
40 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages
28 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages