MTS Series & SCU-200-1

MTS-20H/30H Tilt Switches & SCU-200 Control Unit • • • • • • • • SCU-200 Control Unit Easy to Install - requires little maintenance Control Unit will interface with any tilt switch probe Control Unit provides at-a-glance circuit status Adjustable time delay prevents false indication Rugged and reliable welded steel probes NEMA 12 or optional NEMA 4 enclosure Optional intrinsically safe unit Optional stainless steel probes available Product Information Description The Electro Sensors’ Tilt Switch is a simple system consisting of a control unit and a sensing probe. It is widely used in the process industry to sense the presence or absence of any bulk material. Typical applications include: high or low bin level alarms, detection of transfer chute plug-up, control of material depth in crusher bowls and the sensing of alarm conditions in rock box, screen classifiers and more. Normal or safe condition may be vertical, as in a screen classifier properly loaded — an excessive level tilts the probe to indicate an alarm. Normally tilted condition is typified by material flowing on a conveyor belt — loss of material drops the probe to the vertical position to indicate alarm. High or Low Bin Level Detection Principle of Operation Tilt Switch Probes feature rugged welded steel construction. They are airtight, waterproof, dust and dirtproof, and have a stress relieved cable. The mercury switch inside the probe is epoxy encapsulated to seal it from even the most severe environmental conditions. The probe mounted in a vertical position has closed contacts. As it is tilted to approximately 15 degrees, contacts will open. The contacts have a maximum capacity rating of 230 Vac, 1.7 Amps. The probe is supplied with a flexible 8-foot Neoprene jacketed 18-gauge, two-wire conductor cable suitable for conduit or stand-alone wiring. The SCU-200 Control Unit provides a safe low voltage power source for any probe. Input from the probe is switch selectable so that either tilted or vertical position may be selected as “safe.” The opposite position results in alarm, following an adjustable 1-99 second relay output delay. The delay assures reliable performance, free from false alarms, because only a sustained change in the probe position will initiate an alarm. Lamps are mounted on the face of the enclosure to indicate the SAFE/ALARM status of the output relay (5 amp DPDT). The control is “fail-safe,” relay failure or power loss causes an immediate alarm. Installation Instructions Probe may be suspended from the threaded conduit adapter hanger. Cable length should be adjusted so it won't affect tilting of the probe body. Control unit may be remotely located in any convenient place. See wiring diagram for terminal block layout. Tilt switch hangers (supplied as standard) are all welded steel to match the probe body and are threaded to screw directly onto 1/2-inch NPT conduit. Optional stainless steel hangers and probes are also available. Auxiliary Sensor Power: The SCU-200 Control Unit has a sensor input feature that adds to its versatility. Terminal TB2-1 is a 12 Vdc sensor supply terminal that enables the use of open collector sensors such as Hall-effect and proximity sensors with the control unit. This feature may be used in a wide variety of sensing applications where an adjustable relay output is desired when the sensor detects a target. 6111 Blue Circle Drive Minnetonka, MN 55343 Phone: 952-930-0100 Fax: 952-930-0130 ISO9001:2000 Certified Free Catalog and Application Assistance

 Open the catalog to page 1
MTS Series & SCU-200-2

MTS Tilt Switches & SCU Control Unit Time Delay Adjustment The Relay Output Time Delay function is adjustable from 1-99 seconds. Use a small screwdriver to turn the rotary switches S2 and S3 for the desired time delay interval. Switch S2 adjusts for single seconds, and switch S3 adjusts for tens. Example: A time delay of 14 seconds would Probe Status Switch With the probe status switch in the "A" position, the relay is energized, and the green "SAFE" lamp is lit when the probe is tilted. With the probe status switch in the "B" position, the relay is energized and the green "SAFE" lamp is lit...

 Open the catalog to page 2

All Electro-Sensors catalogs and technical brochures

  1. HazardProTm

    12  Pages

  2. VTHP

    2  Pages

  3. TT420-LT

    2  Pages

  4. TT420

    2  Pages

  5. RTD/RTD-LT

    2  Pages

  6. PM500

    2  Pages

  7. TR400

    2  Pages

  8. TR5000

    2  Pages

  9. SG1000A

    2  Pages

  10. SG1000B

    2  Pages

  11. SG1000C

    2  Pages

  12. SG1000E

    2  Pages

  13. AIFO-200

    2  Pages

  14. VS1/ VS2

    2  Pages

  15. VUM800

    2  Pages

  16. MS320

    2  Pages

  17. MS196

    2  Pages

  18. MS332

    2  Pages

  19. SA420

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.