AIFO-200

AIFO-200

AIFO-200

Product catalog summary
Overview: The AIFO-200 is an interface module designed to convert analog signals (0-10 Vdc or 4-20 mA) into frequency signals for use with devices like closed-loop controllers or electronic counters. It features a regulated 10 Vdc output for module input if needed, and includes zero and span potentiometers for output frequency calibration.
Specifications:
  • Input Power: 115 Vac ± 10% standard, 230 Vac ± 10% optional, 50-60 Hz frequency, 4 VA wattage.
  • Analog Input: 0-10 Vdc with 500K Ohms impedance, 4-20 mA with 500 Ohms impedance, 10 Vdc reference voltage at 10 mA max.
  • Output Signal: Frequency ranges from 0-600 Hz to 0-20 kHz, NPN open collector digital signal type, 0-15 Vdc square wave level.
  • Environmental: Operating temperature 0°C to +70°C, storage temperature -65°C to +105°C, chassis mounting.
Calibration Procedures:
  • 0-10 Vdc Input: Set SW1 to 0-10 Vdc, adjust R16 zero potentiometer for 0 Hz, apply 10 Vdc and adjust R10 gain potentiometer for desired frequency.
  • 4-20 mA Input: Set SW1 to 4-20 mA, adjust R6 offset and R16 zero potentiometers for 0 Hz, apply 20 mA and adjust R10 gain potentiometer for desired frequency.
  • Inverse Proportional Output: Set SW1 and jumpers J1, J2 to inverse position, adjust R6 offset and R16 zero potentiometers, apply 0 Vdc or 4 mA and adjust R10 gain potentiometer.
Additional Notes: The AIFO-200 is factory calibrated for 0-10 Vdc input and 0-2500 Hz output. A frequency measuring device is required for calibration, and a pull-up resistor may be necessary for frequency output.
See more

Catalog excerpts

AIFO-200-1

Superior • Systems • Solutions Frequency Conversion Module Offset and Gain Adjustments 1 - 20 Khz Output Switch Selectable Inverse proportional Outputs Available Multiple Position Mounting Bracket NPN Open Collector or Driven Output Product Information The model AIFO-200 is an interface between analog output devices and frequency input devices. In typical applications a process is monitored by a transducer, PLC, PC or some other device that provides a 0-10 Vdc or 4-20 mA signal. This signal is converted to a frequency and can be used to provide the lead signal to a closed loop controller such as our MicroSpeed 196 or as the input to an electronic counter, tachometer, etc. A regulated 10 Vdc signal is provided on the terminal strip for an input to the module if required. Zero and span potentiometers are provided to calibrate the output frequency to your requirements. Frequency Output Analog Input Analog Common 6111 Blue Circle Drive A^^&k Free Cata'°9 anc' Application Assistance ISO9001:2000 Certified Superior • Systems • Solutions WWW.electro-sensors.COITI

 Open the catalog to page 1
AIFO-200-2

AIFO-200 Calibration Procedure Note A: The AIFO is factory calibrated for 0-10 Vdc Input and 0-2500 Hz Output. Note B: 0 Vdc Input can be obtained by connecting TB1-4 Common to TB1-5 High. A frequency measuring device must be used to calibrate the AIFO-200. Connect the measuring device to Terminal TB1-9 (Common) and TB1-7 (Frequency Output). Determine if your application requires a pull-up resistor for the frequency output. If not required, remove resistor R20 labeled “PULL-UP” on the circuit board. Turn all potentiometers fully counterclockwise. Now turn R16 zero potentiometer 11 turns clockwise....

 Open the catalog to page 2

All Electro-Sensors catalogs and technical brochures

  1. HazardProTm

    12  Pages

  2. VTHP

    2  Pages

  3. TT420-LT

    2  Pages

  4. TT420

    2  Pages

  5. RTD/RTD-LT

    2  Pages

  6. PM500

    2  Pages

  7. TR400

    2  Pages

  8. TR5000

    2  Pages

  9. SG1000A

    2  Pages

  10. SG1000B

    2  Pages

  11. SG1000C

    2  Pages

  12. SG1000E

    2  Pages

  13. VS1/ VS2

    2  Pages

  14. VUM800

    2  Pages

  15. MS320

    2  Pages

  16. MS196

    2  Pages

  17. MS332

    2  Pages

  18. SA420

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.