RS 485 MODULE

RS 485 MODULE

RS 485 MODULE

Product catalog summary
Overview: The document provides technical specifications and configurations for RS485 Modules used in Electrex monitoring systems. These modules are designed to integrate digital and analog inputs/outputs and environmental sensors into a monitoring network.
Specifications: The RS485 Modules are available in two sizes: D2 (2 DIN rail modules) and D4 (4 DIN rail modules). The D2 requires a 24Vdc power supply, while the D4 operates on 230Vac, with other power supply options available upon request. Both modules can accommodate up to two internal modules, with specific configurations for digital and analog inputs/outputs.
Internal Module Types: The document lists various internal module types, including digital inputs/outputs, analog outputs, relay outputs, and sensor interfaces. Each type has specific power and operational requirements, such as self-powered options and compatibility with certain sensor types.
Communication and Protocol: The RS485 Modules use the Modbus-RTU protocol for communication, supporting high-speed data transfer with configurable communication speeds up to 38,400 bps. The modules are equipped with a serial RS485 interface protected against overvoltage.
Digital and Analog Inputs/Outputs: The modules support various configurations of digital and analog inputs/outputs, including optically insulated digital inputs with programmable filters and analog inputs compatible with multiple voltage ranges. Relay outputs are available with specific voltage and current ratings.
Ordering Information: The document provides ordering codes for different configurations of the RS485 Modules, detailing the possible combinations of internal modules and power supply options.
Monitoring System Integration: An example monitoring system setup is described, illustrating how RS485 Modules can be integrated with gateways and other Electrex devices to form a comprehensive monitoring network.
Additional Information: The document includes a building code diagram for module configuration and notes on compatibility and installation requirements.
See more

Catalog excerpts

RS 485 MODULE-1

RS485 Module► Alarm commands, counting, analog and environmental meas, digital, relay and analog outputs► For the data synchronization, log and graph display and alarm notifications must be used in an Electrex monitoring system including a gateway and datalogger RS485 MODULE_ The RS485 Module are devices to be included in an Electrex RS485 monitoring network for adding digital and/or analog inputs/outputs and/or sensors for environmental parameters. Available in two different sizes: 2 DIN rail modules (RS485 Module D2) and 4 DIN rail modules (RS485 Module D4). The RS485 Module D2 must be used with an external power supply of 24Vdc (e.g. Switching Power Supply D1 24VDC 400mA code PFTP100-Q2) and can contain up to 2 modules, of different type, among the ones listed in the table below (of which, however, only one of the two types can be self powered, therefore only one for 1DI 2DO Self-Powered or 2AO4-20mA or 2DI 1RO Self Powered). Dimension 2 DIN rail modules. Max. weight 45 gr. The RS485 Module D4 must be powered at 230Vac (other power supply versions on request, see table* below) and can contain up to 2 modules, of different type, also self-powered among the ones listed in the table below. Dimension: 4 DIN rail modules. Max. weight: 100 gr. *Internal module types for the RS485 Module D2 and D4 • 1DI 2DO: 1 digital input and 2 digital outputs; • 1DI 2DO Self-Powered: 1 self powered digital input and 2 digital outputs; • 2AO 4-20mA: 2 analog self-powered 4-20mA outputs for loads up to 250 ohm, power supply needed for higher loads; • 2DI 1RO Self-Powered: 2 self-powered digital inputs and 1 relay output rated at 30V 2A (resistive load); • 2RO24VDC: 2 relay output rated at 30V 2A (resistive load); • 2RO230V: 2 relay output rated at 250V 2A (resistive load); • 2DI 2DO: 2 digital inputs and 2 digital outputs; • I2C: for connecting environmental sensors Deca Sensor Bus Unit Box (T, TH, TL, THL, THLB, L, B, up to 4 T) The RS485 Module equipped also with a serial RS485, protected against overvoltage. The protocol used is the Modbus-RTU “full complianf’( suitable for communicating with a PLC or a SCADA The data are read as numerical registers composed by mantissa and exponent in the IEEE format. The communication speed of the RS485 port is configurable, up to 38.400 bps, with a max. 125 registers requested (equivalent to 62 parameters) with no waiting time between two requests assuring a high speed. Digital Inputs_ The 1DI or 2DI or 4DI modules is equipped with an optically insulated digital input with programmable filter for input glitches. The digital input is set to operate for external pulse count of, example, water meters, gas meters (insulation to meet the ATEX requirements), water meters, quantity count, etc. For the 1DI or the 2DI 1RO the max sampling frequency is 100Hz (5ms), while for the 2DI 2DO and the 4DO 500Hz (2ms). Other user selectable operative modes are ON/OFF state input (example for reading the ON/OFF state of machines and switches) and tariff change input (example for day-night tariff changeover). The digital input requires an external 10-30Vdc power supply. modules instead are provided with self powered digital inputs. The 4AI module is equipped with 4 analog inputs rated at -10-10V (compatible with 0-10V, 0-5V, -5-5V, 4-20mA at 200 ohm). Versions .. 4PT100 or 4PT1000 or 4NTC are equipped with 4 inputs for the relative sensors. Digital Outputs_ The 2DO or 4DO 4DO are equipped with two optically insulated transistor outputs rated 27 Vdc 27 mA according to DIN 43864 standards. The two outputs may be set for the transmission of pulses or alternatively configured as outputs of the internal alarms (see Alarms) or as remote output devices controlled via serial line and Modbus commands. The 1DI 2DO Self-Powered instead is equipped with two optomos outputs rated at max 250V 100mA aC/dC. Relay Outputs_ The 2DI 1RO Self-Powered and 2RO24VDC modules are equipped with one or two relay outputs with changeover contact rated at max 30V max 2A (resistive load). The 2RO230V instead is equipped with two relay outputs with changeover contact rated at max 250V max 2A (resistive load). The 2AO4-20mA module is equipped with 2 galvanic insulated analogue outputs 4-20 mA or 0-20 mA providing an extremely high accuracy and signal stability. The outputs are active for resistor loads up to 250 ohm, for higher loads an external power supply (12Vdc) will be needed (up to 750 ohm). The outputs ensure a response time of max. 200 ms. Each output can be associated to any of the parameters.

 Open the catalog to page 1
RS 485 MODULE-2

INGRESSI/USCITE DIGITALI/ANALOGICHE E AMBIENTALI A monitoring system including RS485 Module The SI module is used to connect several sensors with various combinations (eg up to 8 parameters between temperature and relative humidity or 1 for temperature, 1 for relative humidity, 1 for luminosity and 1 for air pressure) . The maximum total distance of the Sensor Bus is 20 m. The monitoring system example here below includes a gateway (a Kilo net or an Exa net or the Femto ETC net or the Yocto net ) which from one side serves as a bridge toward the Ethernet / Internet or the PC and from the other...

 Open the catalog to page 2