Libra Energy Automation Panel • • • • • • Plug & Play Non-invasive installation on the system Connectivity (Ethernet, Wi-Fi, RS485, NFC) Flexibility (open platform) Continuous monitoring (e.g. ISO 50001) Energy efficiency and White Certificates Libra represents the advanced technology, ‘Plug & Play’ solution for monitoring and managing Low and Medium Voltage electrical loads, analyzing Power Quality, measuring Direct Current of production from renewable sources and measuring environmental, process and/or air quality parameters. The Libra is configured according to the needs and tailored to the system, consists of multiple measurement modules and allows a quick and simple non-invasive installation on the existing system. It is possible to integrate the Libra measurement system into an existing Electrex monitoring network, or use it as a system head or starting point for more complex supervision systems thanks to the possibility of connecting other Electrex devices in the RS485 subnet and/or Ethernet network. The instrument accuracy is Class 0.5S for Active Energy. It manages the measurements of the single harmonics up to the 51st order and Power Quality with functions relating to the EN 50160 standard (peaks, holes, interruptions, harmonics) and to EN 61000-4-30 for Class S with graphic detail of the events, table and time-line of events, measurement campaigns with selectable parameters and programmable sampling rate. The Libra is battery-powered (DC UPS) to ensure continuous power supply to the measurement system, particularly recommended in cases where automated operations and/or alarms are activated and to ensure continuous monitoring of Energy Quality events. The Libra is equipped with an astronomical clock/calendar and non-volatile memory for the synchronous recording of energy and environmental vectors. Via the integrated Web server it is then possible to supervise the system by displaying instantaneous and graphical measurements. The Libra Net can also be equipped with inputs for Electrex environmental sensors (for example temperature, humidity, brightness, pressure, CO2, Air Quality, etc.) and / or digital inputs / outputs (status / counting) and / or inputs / analog outputs. Versions of Libra The Libra is available in the following versions: • Libra ECT UPS: equipped with high-precision CTs even on small currents, designed for electrical loads up to 50kW and / or non-invasive connection, for integration purpose, to existing and suitable CTs already installed on the system (can be used only with the ECT Electrex Current Transformers). • Libra F UPS: uses split and flexible CTs that are easy to install, recommended in those cases where it is not easy to insert standard CTs (can be used only with the Electrex FCTS series flexible split CTs). • Libra UPS: can be used with the standard ../5A or ../1A output CTs. Plug & Play All versions of the Libra series are equipped with connectors and pre-wired solutions for a quick, error-free installation; they are preconfigured and / or configurable via web pages or the Energy Brain software. CEI EN 50470 and 62053-22 All versions of Libra series meet the essential requirements of the CEI EN 50470-1 + 50470-3 and 62053-22 standards as required for the White Certificates - Energy Efficiency Certificates. Electrex is a brand of Akse srl Via Aldo Moro, 39 42124 Reggio Emilia Italy Tel. +39 0522 924 244 Email: [email protected] Web: www.electrex.it Simplicity The Libra is equipped with a high contrast dot matrix FSTN display with white LED backlighting which allows the simultaneous reading of 4 measurements and their identification symbol with high visibility characters. The 6-key keyboard arranged as a Joystick and the display menu column for configuration allow a simple and rational use of the instrument. While the first, default page displayed at power up can be defined by the user. On the front there are two red LEDs for calibration and control that pulse with a frequency proportional to the imported active and reactive energy. A red LED that pulses under the symbol next to Electrex indicates its operation, while 2 other LEDs under the white band indicate the communication activity of the RS485 port. 1 Engineered and manufactured in Italy
Open the catalog to page 1Phase sequence The Libra permits the identification of the correct phase sequence using the vector diagram (graph on web page). The Libra can be inserted on any type of network: singlephase, two-phase, three-phase with 3 and 4 wires, symmetrical or asymmetrical, balanced or unbalanced, low and medium voltage, with 1, 2 or 3 CTs as well as for measurements on 2 and 4 quadrants (import / export). The voltage inputs and power supply are protected by a fuse. A simple programming from the keyboard or embedded web page (or from Energy Brain software) allows you to set all the operating parameters such...
Open the catalog to page 2Alarms The Libra outputs can be programmed as alarms, each alarm can be associated with any of the available parameters and can be configured as both a minimum and a maximum alarm. Furthermore, all the alarm outputs can refer to the same parameter to have more alarm thresholds. It is possible to set an activation delay (1-99 sec.), an hysteresis (in% of the threshold value) and the polarity of the output contact (NO, NC). The status of the alarms is always available on the serial line (via Modbus “coils”). The alarms can be configured from keyboard, embedded web server and/or from Energy Brain...
Open the catalog to page 3ACTIVATING OTHER FUNCTIONS VIA PUK CODES The Libra includes a WEB Server that can be used for configuring the device remotely and its firmware can be updated remotely at any time. Therefore it is possible to add and / or replace the features already present with new and different functions. New features can be activated by implementing the following Net Upgrades: Net upgrade WEB (PUK) PFSU940-05 Enables the display of the measurements on Web pages of the same device and of slave Electrex devices / panels connected in the RS485 subnet. Net upgrade Log 8 (PUK) PFSU940-01 By activating the PUK Log...
Open the catalog to page 412 Pages
82 Pages
12 Pages
12 Pages
12 Pages
7 Pages
2 Pages
1 Page
2 Pages
1 Page
1 Page
12 Pages
4 Pages
1 Page
4 Pages
12 Pages
4 Pages
1 Page
2 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
3 Pages
6 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
3 Pages
8 Pages
4 Pages
66 Pages
8 Pages
12 Pages
4 Pages
8 Pages
8 Pages
4 Pages
4 Pages