
Libra CCI CEI 0-16 UPS Power Plant Controller (PPC / CCI) • Compliant with CEI 0-16 annexes O–T • Functionality of active power limitation upon external DSO command of inverters (PF2) • Plug & Play - Flexibility (open platform) • Energy efficiency and White Certificates (TEE) • Connectivity (Ethernet, LTE Modem, GPS, RS485) The Libra CCI UPS is the Electrex solution for monitoring production plants in compliance with the CEI 0-16 standard, annexes O–T, following the Arera 540/2021/R/EEL resolution and the subsequent 385/2025/R/EEL, which mandates that photovoltaic and wind plants ≥ 100 kW, both new and existing and connected to the MV grid, must be equipped with a Central Power Plant Controller (CCI) with the functionality of “Active Power Limitation on external DSO command” for inverters (PF2). The Libra CCI is a complete “Plug & Play” solution to collect plant information and securely transmit it to the distributor (DSO) for monitoring and management of electrical loads, measurement of renewable energy production, other energy vectors, and environmental parameters. The Libra CCI meets all functional specifications required by CEI 0-16, namely: • Mandatory: related to data exchange (P, Q) between the producer and DSO and the PF2 functionality (for plants ≥100 kWp) • Optional: related to voltage and power regulation at the delivery point • Voluntary: related to participation in the Dispatching Services Market. The Libra CCI energy analyzer has a measurement accuracy class ≤ 0.2, as required in CEI 0-16:2025-04 Annex O (normative), Central Power Plant Controller (CCI), section O.13.2.1. The Libra CCI energy analyzer has a measurement accuracy class ≤ 0.2, as specified in the technical standard CEI 0-16:2025-04, Annex O (normative), Plant Central Controller (CCI), section O.13.2.1. The Libra CCI can also be used as a starting point/master unit for more complex supervision systems, thanks to the ability to connect additional Electrex devices via RS485 subnetwork and/or Ethernet network. The Libra CCI is equipped with a real-time clock and memory for the synchronous recording of energy and environmental vectors. Through the integrated Web Server, it is possible to supervise the system by displaying instant measurements and graphical trends. The Libra CCI includes an internal DC UPS (battery backup) to ensure continuous power supply to the measurement system — a feature particularly recommended in cases involving automated operations and/or alarms. In addition, the Libra CCI is equipped with five opto-isolated digital inputs (for status and/or counting) and three relay digital outputs (for status and/or pulse control, with other versions available upon request). It also manages Power Quality (PQ): detecting and recording various events in compliance with EN 50160 (voltage sags, swells, interruptions, harmonics) and EN 61000-4-30 Class S, with graphical event details, event tables and time-lines, measurement campaigns with selectable parameters, and programmable sampling frequency. Versions of Libra CCI The versions of Libra CCI are divided into: • Libra CCI ECT UPS: designed for non-invasive connection to existing and suitable CTs already mounted into the system (ECT Electrex Current Transformers are required in order to integrate the existing CTs). • Libra CCI UPS: connects to standard CTs ../5A or ../1A.. Plug & Play All versions of the Libra CCI series are equipped with connectors and pre-wired solutions for a quick, error-free installation; they are preconfigured and / or configurable via web pages or the Energy Brain software. Simplicity The Libra CCI units are equipped with a high-contrast FSTN dot-matrix display with white LED backlighting, allowing the simultaneous reading of four measurements along with their identifying symbols, displayed in high-visibility characters. The six-button keypad allows for simple and intuitive operation of the instrument, while the startup display page can be defined by the user. On the front panel, there are two red calibration LEDs that flash at a frequency proportional to the imported active and reactive energy, a red LED below the Electrex logo indicating device operation, and two LEDs beneath the white band that signal RS485 communication activity. Compliance: CEI 0-16, CEI EN 50470 and 62053-22 The Libra CCI complies with CEI 0-16 annexes O–T. All versions use analyzers meeting essential requirements of CEI EN 50470-1 + 50470-3 and 62053-22, as required for white certificate (TEE) applications. Electrex is a brand of Akse srl Via Aldo Moro, 39 42124 Reggio Emilia Italy Tel. +39 0522 924 244 Email: [email protected] Web: www.electrex.it 1 Engineered and manufactured in Italy
Open the catalog to page 1Active Power Limitation Function on External DSO Command (PF2) The PF2 functionality (“Active Power Limitation on External DSO Command”) is the new operational requirement introduced by Resolution 385/2025. grid, allows the plant to reduce its active power upon direct command from the distribution system operator (DSO) or Terna (the Italian transmission system operator). Phase sequence The Libra CCI permits the identification of the correct phase sequence using the vector diagram (graph on web page). The Libra CCI can be inserted on any type of network: singlephase, two-phase, three-phase with...
Open the catalog to page 2Alarms In case the Libra CCI outputs are programmed as alarms, each alarm can be associated with any of the available parameters and can be configured as both a minimum and a maximum alarm. Furthermore, all the alarm outputs can refer to the same parameter to have more alarm thresholds. It is possible to set an activation delay (1-99 sec.), an hysteresis (in% of the threshold value) and the polarity of the output contact (NO, NC). The status of the alarms is always available on the serial line (via Modbus “coils”). Libra ECT net per TA ECT The Libra CCI ECT UPS use exclusively the Electrex ECT...
Open the catalog to page 312 Pages
82 Pages
12 Pages
12 Pages
12 Pages
7 Pages
2 Pages
1 Page
2 Pages
1 Page
1 Page
12 Pages
4 Pages
1 Page
4 Pages
12 Pages
4 Pages
1 Page
2 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
3 Pages
6 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
3 Pages
8 Pages
4 Pages
66 Pages
8 Pages
12 Pages
4 Pages
8 Pages
8 Pages
4 Pages
4 Pages