EMU-1800SD

EMU-1800SD

EMU-1800SD

Product catalog summary
Specifications:
Model: EMU-1800SD
Construction: Stationary / Automatic on Container
Control Panel: AUT-MP12
Container Type: 40HC-I2
Output in Standby Service: 1,540 kVA / 1,232 kW
Output in Prime Service: 1,400 kVA / 1,120 kW
Voltage: 400 V, 3 + N phases
Power Factor: 0.8 - 1
Speed: 1,500 rpm
Frequency: 50 Hz
Sound Level: 85 dBA at 1 m
Performance:
Standby Current Intensity: 2,223 A
Prime Current Intensity: 2,021 A
Voltage Precision: ±0.5%
Frequency Variation: ±0.5%
Coolant Heater Output: 9,000 W
Admissible First Step Load: 740 kW
Operating Conditions:
Max Continuous Power: According to ISO-8528-1 at 40ºC and 1000 m altitude
Overload Capacity: 10% for 1 hour every 12 hours
Recommended Load: 70% PRP in main service, 80% LTP in standby
Dimensions and Consumption:
Dimensions: 12,190 x 2,440 x 2,900 mm
Weight (empty): 18,510 kg
Fuel Tank Capacity: 2,000 l
Specific Fuel Consumption: 0.26 l/kW-h
Fuel Consumption at 75% Load: 239 l/h
Engine Details:
Engine Make and Model: MITSUBISHI S12RPTA2
Cycle: Diesel 4 stroke
Cooling: Water-cooled radiator
Cylinders: 12 in V-form
Total Swept Volume: 49.03 l
Air Aspiration: Turbocharger with water-air cooler
Speed Governor: Electronic
Total Oil Capacity: 180 l
Oil Consumption: 1 l/h
Cooling Circuit Capacity: 268 l
Alternator Details:
Alternator Make and Model: LEROY SOMER LSA 502 VL10
Connection: Star
Insulation Class: H
Voltage Regulator: AREP R450
Short-Circuit Current: 3 In for 10 seconds
Protection: IP-23
Batteries:
Quantity: 4
Connection: 2 parallel of 2 in series
Voltage: 24 V
Capacity: 210 Ah each
Type: Lead-acid
See more

Catalog excerpts

EMU-1800SD-1

Generating set technical data: Model Electra Molins EMU-1800SD STATIONARY / AUTOMATIC ON CONTAINER MDDEL: EMU-1BDDSD Fdrm of Cdnstructidn: Stationary / Automatic on Container Brand of the Genset Control panel type Container Type Output in standby service on mains failure (LTP "Limited Time Power" according to norm ISO 8528-1) Output in prime service (PRP "Prime Power" according to norm ISO 8528-1) Tolerance of the maximum active power (kW) Current intensity in standby service on mains failure Current intensity in prime service Voltage N° of phases Precision of the voltage in steady state Range of voltage adjustment Power factor Speed Frequency Frequency variation in steady state Coolant heater output (only for automatic construction) Admissible first step load Mean sound level at 1 m (tolerance ±2 dB) Date: 31/08/2017. Electra Molins reserves the right to modify these specifications according to its own technical criteria.

 Open the catalog to page 1
EMU-1800SD-2

Generating set technical data: Model Electra Molins EMU-1800SD STATIONARY / AUTOMATIC ON CONTAINER MITSUBISHI S12RPTA2 Diesel 4 stroke Water-cooled radiator 12 in V-form 49,03 l Turbocharger with water-air cooler Electronic 180 l 1 l/h 268 l Length x Width x Height Weight empty of fuel Fuel tank capacity Specific fuel consumption Fuel consumption with 75% of load (924 kW) Make of the engine and model Cycle Cooling N° and configuration of the cylinders Total swept volume Air aspiration Speed governor Total oil capacity Oil consumption at full load Capacity of the cooling circuit (40% antifreeze...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.