coating thickness gauge 1
Open the catalog to page 1Dry Film Thickness - Digital Elcometer 456 Separate Coating Thickness Gauge The Elcometer 456 coating thickness gauge is available with a wide range of interchangeable probes; providing greater coating thickness measurement flexibility on metal substrates. Easy to read, user definable display with automatic screen brightness Measure coatings up to 31mm (1,220mils) on metal substrates Temperature stable measurements wireless technology Ergonomic design, ideal for continuous use Dust and waterproof rugged design equivalent to IP64
Open the catalog to page 2Dry Film Thickness - Digital Separate Coating Thickness Gauge Helping you become more efficient 70+ readings per minute and 140+ per minute with Scan Probe, multiple calibration memories and alphanumeric batch identification. Elcomet Large easy to read measurements in Metric and Imperial units Accurate measurements on smooth, rough, thin and curved surfaces Measures on smooth, rough, thin and curved surfaces to ±1% in accordance with National & International Standards. Large buttons and colour screen Halve the inspection time using the scan probe LCD screen with auto rotate; factory calibrated...
Open the catalog to page 3Dry Film Thickness - Digital Elcometer 456 Separate Coating Thickness Gauge Scan and Auto Repeat Modes Using the Scan Probe in Scan Mode Using the Elcometer 456 in Scan Mode with the Scan Probe enables users to significantly reduce dry film thickness inspection times without affecting accuracy: • Slide the Scan Probe over the entire surface area, as the probe is lifted off the surface the gauge displays the average coating thickness value, the highest thickness and the lowest thickness values. • Each set of three readings (average, high and low) can be displayed on the run graph and stored into...
Open the catalog to page 4Dry Film Thickness - Digital Separate Coating Thickness Gauge Scan Probes The Scan Probes further enhance the speed and accuracy of field based dry film coating thickness measurement: • • • • • Featuring a highly durable ‘snap on’ replaceable probe cap A revolutionary design which allows users to take individual readings or rapidly scan large surface areas - without damaging the probe or coating Uses the Elcometer 456’s patented offset feature1, ensuring that any cap wear during use2 is incorporated within the calibration process - the gauge even informs the user when to replace the cap. Standard...
Open the catalog to page 5Dry Film Thickness - Digital Elcometer 456 Separate Coating Thickness Gauge Product Features Fast, accurate reading rate; 70+ readings per minute Repeatable & reproducible measurements Easy to use menu structure; in 30+ languages Tough, impact, waterproof & dust resistant; equivalent to IP64 Bright colour screen; with permanent backlight Scratch & solvent resistant display; 2.4” (6cm) TFT Large positive feedback buttons USB power supply; via PC Test certificate 2 year gauge warranty1 Automatic rotating display; 0°, 90°, 180° & 270° Ambient light sensor; with adjustable auto brightness Emergency...
Open the catalog to page 6Dry Film Thickness - Digital Separate Coating Thickness Gauge Product Features Automatic calibration; for rapid calibration Calibration memory type; gauge (g) or gauge & batch (gb) Number of batches; with unique calibrations Calibration memories; 3 user-programmable memories Measurement outside calibration warning Calibration lock; with optional PIN code unlock Delete last reading Gauge memory; number of readings Individual batch calibrations; sent to PC via ElcoMaster® software Limits; user definable audible & visual pass/fail warnings Gauge (g) or gauge & batch specific (gb) limits Date and...
Open the catalog to page 7Dry Film Thickness - Digital Elcometer 456 Probe Range for Separate Coating Thickness Gauge All Elcometer 456 probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application, including; application. Fully interchangeable and available in a number of designs and scale ranges Supplied with a Test Certificate and a set of calibration foils Ferrous, non-ferrous and dual FNF probes available Ergonomic design, ideal for continuous use Temperature stable measurements
Open the catalog to page 8Dry Film Thickness - Digital Probe Range for Separate Coating Thickness Gauge Choosing the correct probe for your coating thickness gauge: Ferrous Probes (F) probes measure non-magnetic coatings on ferromagnetic substrates. • Elcometer 456 ferrous gauges accept any ferrous probe. • Non-ferrous probes measure non-conductive coatings on non-ferrous metal substrates. • Elcometer 456 non-ferrous gauges accept any non-ferrous probe. • Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. • Elcometer 456 FNF gauges accept all ferrous, non-ferrous and...
Open the catalog to page 9Dry Film Thickness - Digital Elcometer 456 Probe Range for Separate Coating Thickness Gauge Choosing the correct probe for your coating thickness gauge: Straight Probes Standard Straight Probe Anodising Probe Standard probes measure coatings on both flat and curved surfaces. Chemical resistant & washable - ideal for the anodising environment. Mini Probe Waterproof Probe Mini probes are ideal for harder to reach areas and edges. Sealed for use underwater at depth, even in diving gloves. Soft Coating Probe Thick Coatings Probe Large surface area probes are for soft materials (HVCA approved). Ideal...
Open the catalog to page 10Dry Film Thickness - Digital Probe Range for Separate Coating Thickness Gauge Choosing the correct probe for your coating thickness gauge: Angled Probes Right Angle Probe Mini Right Angle Probe Take readings in areas with restricted clearance. For measuring coatings on edges, narrow pipes or small surface areas. Telescopic Probe Extending probes for hard to reach areas. Measure difficult to access or complex areas. Plug In Integral Probes (PINIP™) PINIP™ Integral Probe Hi-Temperature PINIP™ Transforms a separate gauge into an integral gauge, ideal for single handed use. Measure coatings on ferrous...
Open the catalog to page 111 Page