Overview: This document is a technical catalogue from EL.CO. detailing temperature transmitters and signal conditioners. It categorizes products into four main types: modules for DIN probe mounting, dip switch configurable modules, PC configurable modules, and serial line converters.
1. Modules for DIN Probe Mounting: These modules are housed in self-extinguishing plastic cases and are programmable via dip-switches. They provide a linear output signal corresponding to the input from the temperature probe, with fine adjustments using zero and span trimmers.
2. Dip Switch Configurable Modules: Compact modules (12.5mm) for DIN bar mounting, allowing configuration of input and output signals through dip switches. They can be non-insulated or have 2000VCA insulation.
3. PC Configurable Modules: Housed in 12.5mm cases, these modules use a microprocessor for continuous function control, accepting various sensors and electrical parameters. They feature continuous self-calibration for precision and stability.
4. Serial Line Converters: Provide complete electrical insulation between lines, using optoisolators and insulated DC/DC converters for 2000VCA insulation.
Technical Specifications: Detailed specifications for models like TS-1110 and TS-1120, including sensor types, input/output configurations, calibration errors, and operating conditions. The TS-1110 is for PT100 sensors, while the TS-1120 supports various thermocouple types.
Standards and Compliance: Products comply with EC standards such as CEE EMC 89/336 and CEE BT 73/23, ensuring electromagnetic compatibility and safety for 230VAC products.
Ordering Information: Instructions for ordering specific models, including options for temperature scale (°C or °F).
Technical Specifications:- Electromagnetic Compatibility: Compliant with EN50081-2 and EN50082-2 standards.
- Thermal Drift: 0.02% of full scale per °C.
- Power Supply Voltage: 12 to 32 V.
- Operating Temperature: -20 to 70 °C.
- Storage Temperature: -40 to 100 °C.
- Relative Humidity: 0 to 90% (non-condensing).
- Weight: 35 grams.
Features:- Supports thermocouple types E, J, K, N, S, R, B, and T.
- Two-wire 4-20 mA voltage linear output.
- Zero and span programmable via DIP switch.
- High precision and performance stability.
- Suitable for DIN B connection heads.
- Low cost and available in °C and °F scales.
Operating Instructions: Power the transmitter with 12 to 32 V between -V and +V terminals. Ensure RLoad is within the working area based on power supply voltage. Available in 6 versions for common sensors. Zero and span adjustments are made using potentiometers for calibration.
Programming Instructions: Sensor selection and zero/span programming are done via DIP switches. Specific configurations for thermocouple types K, J, R, S, and T are provided.
TS-2065 Transmitter: For Pt100 thermoresistance, compliant with IEC 751. Output: 4-20 mA, programmable zero and span. EMC compliant, suitable for DIN rail mounting. Calibration is independent for zero and span settings.
Applications: Temperature monitoring and control in process controls, automation systems, and energy management.
Specifications: The document outlines specifications for temperature transmitters and signal conditioners, specifically models TS-2165 and TS-2015. Key specifications include response time, warm-up time, calibration error, transmission error, and EMC compliance.
Features: Pt100 input with configurable input range and output signal via DIP switches. Linearized output available in voltage or current. Independent zero and full scale adjustments. EMC compliant with CE mark. DIN rail mounting capability. Optional double channel transmitter with 2 inputs and 2 outputs (Model TS-2166).
Ordering Information: Instructions for ordering include specifying the input and output configurations. The document provides examples of how to order specific configurations.
Operating Instructions: The TS-2165 converter requires a power supply voltage between 18V and 30V. The Pt100 sensor and output signal connections are detailed, along with instructions for configuring input and output using DIP switches. Calibration is performed using zero and span adjustments.
Applications: The TS-2015 is suitable for temperature monitoring and control in process controls, automation systems, and energy management. It supports various input types, including RTD, thermocouple, current, voltage, resistance, and potentiometer inputs.
Configuration: The TS-2015 can be configured using a PC with Windows95™ and the PROSOFT software. The configuration process is guided by a menu-driven program, allowing for easy programming of zero and full scale values. The device can be reconfigured multiple times, even while in operation.
Technical Specifications: Technical specifications for the TS-2015 include typical performance at 25°C under nominal conditions. The document provides detailed configuration options for inputs and outputs, including linearization and sensor burnout settings.
Overview: The document provides technical specifications and configuration details for the TS-2115 Smart Signal Conditioner, used for temperature monitoring and control in various applications such as process controls, automation systems, and energy management.
Specifications:- Input Types: Configurable for RTD (PT100, PT1000, Ni100, Ni1000), thermocouples (8 types), current (-10 to +24 mA), voltage (-400 to +700 mV or -10V to +10V), resistance (20 Ohm to 2 KOhm), and potentiometer (20 Ohm to 50 KOhm).
- Output: Programmable current or voltage output in the range of 0 to 20 mA or 0 to 10V. Includes sensor burnout alarm and short circuit protection.
- Accuracy: High precision with linearity of ±0.1% for RTD and ±0.2% for thermocouples.
- Thermal Drift: ±0.01%/°C for full scale and cold junction compensation.
- Environmental Conditions: Operating temperature range from -20°C to +70°C and humidity from 0 to 90% (non-condensing).
- EMC Compliance: Conforms to EN50081-2 for emissions and EN50082-2 for immunity, with RF immunity tested up to 10V/m at 1000MHz.
Configuration: The TS-2115 can be configured using a PC with Windows95™ and the PROSOFT software, along with the EL.CO.TS-03 interface adapter. The device can be reconfigured multiple times, even while in operation, without mechanical adjustments.
Ordering Information: Devices can be ordered as non-configured or pre-configured based on user specifications. Configuration options include input type, linearization, RTD and TC options, and output settings.
Applications: Suitable for use in process controls, automation systems, and energy management, with features like high accuracy, on-field reconfigurability, and DIN rail mounting.
Technical Specifications and Features: The document provides detailed specifications for the TS-4035 and TS-4135 temperature transmitters and signal conditioners. These devices are designed for temperature monitoring and control in various applications such as process controls, automation systems, and energy management.
Input Types: The TS-4035 and TS-4135 are configurable to accept multiple input types, including RTD inputs for PT100, PT1000, Ni100, and Ni1000 with 3 or 4 wire cable compensation, thermocouple inputs for 8 different types with selectable internal or external cold junction compensation, current inputs from -10 to +24 mA, voltage inputs up to -400/+700 mV or +/-10 V, resistance inputs for linear resistance measurement from 20 Ohm to 2 KOhm with 3 or 4 wire compensation, and potentiometer inputs from 20 Ohm to 50 KOhm.
Output Specifications: The devices offer programmable or standard 4-20 mA current output. They include features such as sensor burnout alarms (upscale or downscale) and protection against polarity reversal.
Configuration and Setup: Configuration is performed using a PC with Windows95™ and the PROSOFT software, along with the EL.CO.TS-03 interface adapter. The software guides users through the configuration process, allowing for programming of zero and full-scale values. The devices can be reconfigured multiple times, even while in operation.
Technical Performance: The document outlines the accuracy, linearity, calibration, and thermal drift specifications for various input types. It also details the load resistance, supply voltage, and environmental conditions such as operating temperature and humidity.
Ordering Information: The document provides a checklist for ordering configured units, specifying input types, linearization options, output current range, and sensor burnout settings.
Physical and Installation Details: The devices are designed for DIN rail mounting and are housed in self-extinguishing plastic. They weigh approximately 50 grams and have specific dimensions outlined in the document.
Specifications: The TS-4135 is a versatile signal conditioner with programmable current or voltage output ranging from 0 to 20 mA or 0 to 10 V. It features sensor burnout detection, configurable as either "Upscale" or "Downscale", and includes short circuit protection on the output. The device supports various input types including RTD, thermocouple, mV, V, mA, resistance, and potentiometer inputs. It is galvanically isolated and can be configured via a PC using the PROSOFT software.
Set-Up and Configuration: Configuration is performed using a PC running Windows95™ and the PROSOFT software, which communicates with the TS-4135 via an interface adapter. The device can be pre-configured and calibrated according to customer specifications upon request. The configuration process is straightforward, allowing for on-field reconfiguration without interrupting normal operations.
Ordering Information: The TS-4135 can be ordered as a non-configured or pre-configured device. The ordering process involves specifying the desired sensor type, operating range, and output configuration. An example configuration includes a TC type J sensor operating from 0 to 600°C with a 0 to 10 V output and upscale sensor burnout alarm.
Technical Specifications: Typical specifications at 25°C include RTD input range: PT100 (-200°C to 850°C), PT1000 (-200°C to 200°C), TC input range: Type J (-200°C to 1200°C), Type K (-200°C to 1370°C), Voltage input range: +/- 400 mV to +/- 10 V, Current input range: -10 to +24 mA, Accuracy: ±0.1% to ±0.2% depending on input type, Response time: Approximately 0.4 seconds, Operating temperature: -20°C to +70°C, EMC compliance: EN50081-2 and EN50082-2.
Applications: The TS-4135 is suitable for temperature monitoring and control in process controls, automation systems, and energy management. It supports a wide range of input types and offers high accuracy and stability, making it ideal for various industrial applications.
Specifications: The document outlines the specifications for the TS-4135AC and TS-4530 devices, which are compliant with EMC standards and suitable for DIN rail mounting. The TS-4135AC operates on a power supply of 90-250 Vac and can be configured according to user specifications. The TS-4530 is a universal isolated converter capable of measuring and linearizing various signals, with galvanic isolation and high accuracy.
Configuration Procedures: Configuration of the TS-4135AC is performed using a PC with Windows95™ and the PROSOFT software developed by EL.CO., along with the EL.CO.TS-03 interface adapter. The device can be reconfigured multiple times, even while in operation. The TS-4530 can be configured using dip-switches or a PC, allowing for input type and range selection without recalibration.
Ordering Information: Devices can be ordered as non-configured or configured units. For configured devices, specific parameters such as sensor type, range, and output must be specified. An example is provided for ordering a conditioner for a TC type J sensor.
Technical Specifications: The document provides detailed technical specifications for both devices, including input and output ranges, accuracy, linearity, and thermal drift. The TS-4135AC supports various RTD and TC types, with specific ranges and load resistances. The TS-4530 offers universal configurable inputs and outputs, with options for fast sampling and square root extraction.
Applications: The TS-4530 is suitable for temperature monitoring and control in process controls, automation systems, and energy management. It is designed for use in industrial environments with compliance to electromagnetic compatibility standards.
Threshold Operation and Operating Instructions: The converter requires a direct voltage supply between terminals U and V. It measures input from sensors connected to terminals C-D-E-F-G-H-I-L and outputs the data through terminals M-N-O-P (OUT A) and Q-R-S-T (OUT B). A trip alarm contact is available at terminals A-B. Configuration can be done via dip-switches or software, even when powered.
Alarm Thresholds: High alarm activates the relay when the input exceeds the trip level, deactivating only when it falls below the trip level minus hysteresis or reaches the minimum input scale. Low alarm activates when input falls below the trip level, deactivating when it rises above the trip level plus hysteresis or reaches the maximum input scale.
Technical Specifications: Input types include mV, TC, RTD, Res, Potentiometer, Voltage, and mA, with specific accuracy and linearity parameters. Input impedance for TC and mV is >= 10 MΩ. RTD excitation current is 400 uA. Power supply voltage ranges from 20 to 30 Vdc with reverse polarity protection up to 60 Vdc. Operating temperature is -20°C to +60°C, with storage temperature from -40°C to +85°C.
Programming and Configuration: Configuration can be done via PC using DATESOFT software or by dip-switches. The software allows setting default programming, unavailable options via dip-switch, and real-time input/output reading. Dip-switch configuration involves setting input/output types and scale values.
On Request Converters: Single and double input converters, as well as signal doublers, are available on request with various input types like thermocouple, PT100-PT1000, PTC-NTC, and voltage/current inputs, all isolated in multiple ways.
Notes: Incorrect dip-switch settings are indicated by a blinking PWR LED. Default configurations can be loaded if all dip-switches are set to specific positions.
Specifications: The document provides detailed specifications for temperature transmitters and signal conditioners, specifically the TS-5020 and TS-5021 models. These devices are designed for temperature monitoring and control in process controls, automation systems, and energy management. They feature configurable input and output signals, galvanic isolation, and compliance with electromagnetic compatibility standards.
Installation Instructions: The devices are suitable for DIN rail mounting in a vertical position. It is important to ensure proper ventilation and avoid mounting near heat-generating equipment. Devices should be spaced at least 5 mm apart if the panel temperature exceeds 45°C or if high power supply values are used. Shielded cables are recommended for signal connections.
Technical Specifications: The TS-5020 and TS-5021 models offer a wide range of input and output configurations, including voltage and current signals. They provide 2000Vac isolation among input, output, and power supply, eliminating ground loop effects. The devices support zero and span adjustments and have a response time of 0.5 seconds. They operate within a temperature range of -20°C to 70°C and are housed in a compact 12.5 mm thick enclosure.
Operating Instructions: The TS-5020 requires a power supply voltage between 18Vdc and 32Vdc. Input and output configurations are set using DIP switches accessible by opening a side door on the device. Calibration is achieved through independent zero and span adjustments. The TS-5021 offers similar features with additional support for current loops and auxiliary power supply for connected loads.
Applications: Both models are suitable for industrial applications requiring reliable temperature monitoring and control, with the ability to handle harsh environmental conditions.
Technical Specifications: The TS 5021 is a configurable signal converter with voltage or current output, adjustable via dip-switches. It features 2000Vac galvanic isolation on three ways and provides isolated power supply sources for external transmitters and passive loads. It offers independent zero and full-scale adjustments, is EMC compliant with a CE mark, and is suitable for DIN rail mounting according to EN-50022 and EN-50035 standards. The device ensures high accuracy and stability.
Ordering Information: The TS 5021 is supplied as per customer specifications. If not specified, it defaults to a standard configuration.
Performance Parameters: Calibration error: ±0.1% of full scale, Linearization error: ±0.05% of full scale, Thermal drift: 0.02% of full scale/°C, Response time: <10ms, Operating temperature: -20 to 60°C, Storage temperature: -40 to 85°C, Relative humidity: 0 to 90% (non-condensing).
Operating Instructions: The TS 5021 requires a direct voltage supply between 18V and 32V. Input and output connections should be made according to specified sections. Configuration of input and output ranges is done via DIP-switches, followed by calibration using ZERO and SPAN adjustments.
Installation Instructions: The device is designed for vertical DIN rail mounting. Ensure adequate ventilation and avoid mounting above heat-generating equipment. Maintain a minimum spacing of 5mm between devices under certain conditions.
Isolation Structure: The TS 5021 provides 2000Vac isolation between input, power supply, and outputs, eliminating ground loop effects.
TS 5022 Overview: The TS 5022 is a configurable signal doubler/conditioner with 4-way galvanic isolation, designed to output two independent signals proportional to the input. It features programmable input and output ranges, zero and span adjustments, and is compliant with EEC/336/89 standards on electromagnetic compatibility.
Specifications: The TS-5022 is a signal converter with configurable input and output ranges via dip-switches. It supports both voltage and current signals, with two independent output channels. The device offers galvanic isolation of 2000Vac across three paths and provides isolated power supply sources for external transmitters and passive loads. It features independent zero and full-scale adjustments, is EMC compliant with a CE mark, and is suitable for DIN rail mounting according to EN-50022 and EN-50035 standards. The device is known for its high accuracy and stability.
Technical Specifications: Input signals can be current (4-20 mA, 0-20 mA) or voltage (0-10 V, 2-10 V, 0-5 V, 1-5 V). Output signals are similarly configurable. The device requires an auxiliary power supply of 18V min. @ 20mA and supports a power supply voltage range of 18-32 Vdc. It has a calibration error of ±0.1% of full scale and a linearization error of ±0.05% of full scale. The response time is less than 10ms, and it operates within a temperature range of -20 to 60°C.
Operating Instructions: The TS-5022 must be powered by a direct voltage between 18 V and 32 V. Output and input connections are specified for both voltage and current configurations. The device's input and output ranges are set using DIP-switches, and calibration is done using ZERO and SPAN adjustments.
Configuration & Calibration: Configuration involves setting DIP-switches according to input and output range tables. Calibration requires connecting a simulator to the input and adjusting the ZERO and SPAN potentiometers to calibrate the output channels.
Installation Instructions: The device should be mounted on a DIN rail in a vertical position. Adequate spacing and ventilation are necessary to prevent overheating. It is recommended to avoid placing the device near heat-generating equipment and to use shielded cables for connections.
RS-232 to RS-485/RS-422 Converter: The TS-3580 converter connects RS-232 equipment to RS-485 or RS-422 equipment, extends RS-232 links, and provides noise protection in industrial environments. It conforms to EIA RS-232, RS-422, and RS-485 specifications with a transmission rate from 75 to 115200 baud.
Specifications:- Distance and Rate: The device supports various distances and baud rates, ranging from 1.2 Km at 38.4 Kbaud to 7 Km at 1.2 Kbaud.
- Line Impedance: Typical impedance is 100 Ohm.
- RS-485 Multipoint Connection: Supports up to 32 terminals.
- Power Consumption: Maximum of 35 mA at 24 Vdc.
- Power Supply: Operates on 10-30 Vdc or 9-18 Vac (24 Vac available on request).
- Isolation: 3-way isolation at 2000 Vac, 50 Hz for 1 minute.
- Electromagnetic Compatibility: Compliant with EN50081-2 and EN50082-2 standards.
- Connections: RS-232 side uses DB9 and screw terminal blocks; RS-422 and RS-485 use screw terminal blocks.
- Temperature Range: Operating temperature is -20 to 70°C; storage temperature is -40 to 100°C.
- Humidity: Supports 0 to 90% relative humidity (non-condensing).
- Dimensions: 101 x 119 x 22.5 mm.
- Weight: Approximately 100 g.
Features:- Asynchronous data transmission with automatic baud rate adjustment.
- Transmission rate up to 115.2 Kbaud and distance up to 1200 m.
- Supports both point-to-point and multipoint connections.
- Suitable for DIN rail mounting.
Ordering Information:- Model TS-3580 with options for AC power supply configurations.
Operating Instructions:- RS-422 Point-to-Point Connection: Utilizes a double twisted pair line up to 1.2 Km with a transmission rate of 115.2 Kbaud. No need to set protocol, character format, or transmission rate.
- RS-485 Multipoint Connection: Supports up to 32 terminals over a two-wire line, covering a maximum distance of 1.2 Km at 115.2 Kbaud.
Wiring Diagrams: Block diagrams and physical sizes are provided for installation guidance.