Reading Transducer Specifications
  • Types: TM10C/TM10E and TM100C/TM100E
  • Reading Resolution: 0.1 mm for TM10, 0.01 mm for TM100
  • Accuracy: ±0.1 mm/m for TM10, ±0.05 mm/m for TM100
  • Electronic Zero Pulse: Every 4 mm (type C) or with external magnet (type E)
  • Frequency: 300 KHz
  • Sensor Distance: 0.3 to 1.2 mm
  • Phase Difference: 90° ± 5° electrical degree
  • Max Speed: 12 m/s
  • Vibration Resistance: 300 m/s² (55 Hz to 2 KHz)
  • Shock Resistance: 1000 m/s² (11 m/s)
  • Protection Degree: IP67
  • Operating Temperature: 0 to 50°C
  • Stocking Temperature: -20 to 80°C
  • Humidity: 100% non-condensed
  • Supply: 5/28 Vdc ±5% 60 mA no load
  • Output Signals: Push-pull or line-driver
  • Standard Cable Length: 2 m
  • Electrical Protections: Against polarity inversions and short circuits
Magnetic Band MP200 Specifications
  • Composition: Plasto-ferrite strip with stainless steel carrier
  • Optional: Magnetically transparent stainless steel cover
  • Pole Pitch: 2 + 2 mm
  • Accuracy: ±50 µm/m
  • Width: 10 mm
  • Thickness: 1.3 mm
  • Max Length: 50 m
  • Thermal Expansion: 10.5x10-6°C-1 ref.t.=20°C±0.1°C
  • Operating Temperature: 0 to 70°C
  • Stocking Temperature: -20 to 80°C
System Overview
The TM+MP200 system combines the TM transducer and MP200 magnetic band, operating contactlessly to convert magnetic field measurements into digital signals. It is suitable for harsh industrial environments with water, oil, and grease. The system is easy to mount, cost-effective, and provides accurate, repeatable measurements. The scanning head is compact and robust, available in resolutions of 0.1 mm or 0.01 mm. An electronic zero pulse is generated every 4 mm or matched with external magnets. Compliance with CE standards is noted.
Important Note
To maintain system accuracy, the magnetic band MP200 should be at least 40 mm longer than the machine run on each side.
See more

Catalog excerpts

TMP + MP200 Magnetic transducer-1

TM + MP200 MAGNETIC TRANSDUCER The linear magnetic measuring system TM+MP200 is composed by the magnetic transducer TM and the magnetic band MP200: The transducer works contactless, releaving the polarized fields of the magnetic band and converting the measure into digital signals. The system can be profitably employed in severe industrial environments, in presence of water, oil, grease. The mounting method is easy and cheap and the measure is accurate and repeatable. The scanning head TM is contained in a compact and strong metal case, and it is available with reading resolution 0.1 mm (TM10) or 0.01 mm (TM100). An electronic zero pulse is generated each 4 mm (type TM10C/TM100C), o matching with one or more external magnets (TM10E/TM100E). Complying with CE standards READING TRANSDUCER SPECIFICATIONS TYPE TM10C/TM10E TM100C/TM100E 0.1 mm 0.01 mm Reading resolution ± 0.1 mm/m ± 0.05 mm/m Accuracy each 4 mm (type C) or matching with Electronic zero pulse external magnet (type E) 300 KHz Frequency 0.3 ÷ 1.2 mm Sensor distance 90° ± 5° electrical degree Phase difference 12 m/s Max. speed (55 Hz ÷ 2 KHz) at 300 m/s2 Vibration resistance 1000 m/s2 (11 m/s) Shock resistance IP67 Protection degree 0 ÷ 50° C Operating temperature -20° ÷ 80 C° Stocking temperature 100% non condensed Humidity 5/28 Vdc ±5% 60 mA no load Supply push-pull or line-driver Output signals length 2 m Standard cable for the supply: against polarity inversions Electrical protections for the outputs: against short circuits MAGNETIC BAND MP200 MAGNETIC BAND SPECIFICATIONS The magnetic band MP200 consists of a Pole pitch 2 + 2 mm plasto-ferrite strip, which is polarized at regular Accuracy ±50 µm/m distance, and supported by a stainless steel Width 10 mm carrier; it is equipped with the adhesive tape for Thickness 1.3 mm an easy mounting. 50 m Max. lentgh As an optional, the magnetic band can be Thermal expansion 10.5x10-6°C-1 ref.t..=20°C±0.1°C supplied with a magnetically transparent Operating temperature 0 ÷ 70°C stainless steel cover for physical protection. -20° ÷ 80°C Stocking temperature DIMENSIONS Magnetic Transducer TM + Magnetic Band MP200 ELAP VIA VITTORIO VENETO, 4 – I-20094 CORSICO (MI) – TEL. ++39.02.4519561 FAX ++39.02.45103406 E-MAIL:

 Open the catalog to page 1

All ELAP catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.