1. Catalogs
  2. ELAP
  3. MEM-Bus IO-Link Absolute Encoder

MEM-Bus IO-Link Absolute Encoder

MEM-Bus IO-Link Absolute Encoder

MEM-Bus IO-Link Absolute Encoder

Product catalog summary
Electrical & Operating Specifications
  • Operating principle: Magnetic
  • Resolution: 8192 steps/revolution (13 bits)
  • Revolutions: 65536 (16 bits)
  • Initializing time: Less than 1 second
  • Data memory retention: Over 30 years without power
  • Fieldbus: IO-Link
  • Supply voltage: 10-30 Vdc with protection against polarity reversal
  • Power consumption: 2 W
  • Accuracy: ± 0.2°
  • Connection: M12 4-pin radial connector
  • Interference immunity: EN 61000-6-2
  • Emitted interference: EN 61000-6-4
IO-Link Interface

The IO-Link communication protocol facilitates simplified communication between sensors and Ethernet or fieldbus networks in production lines. It is a point-to-point protocol compatible with most industrial fieldbuses, ensuring easy integration into existing systems. Data transmission is based on a 24V signal, immune to external interference. Key features include accurate data transmission, easy system integration, automated configuration for device replacement, and reduced wiring.

Ordering Information
  • Type: MEM540B (Round clamping flange), MEM520B (Round synchro flange), MEM620B (Square flange 63.5x63.5 mm)
  • Protocol: IO-Link
  • Number of Turns: Multiturn
  • Shaft Diameter: 6, 8, or 10 mm
MEM-Bus IO-Link Encoder Profile
  • Conforms to IEC 61131-9
  • COM3 Communication mode (230.4 kbit/s)
  • IO-Link Version: 1.1
  • Minimum Cycle Time: 1000 μs
  • SIO and ISDU supported
  • Data storage and block parameters supported
Mechanical & Environmental Specifications
  • Materials: Aluminium housing, Stainless steel shaft
  • Weight: Approximately 210 g
  • Shaft/hollow shaft diameter: 6, 8, or 10 mm
  • Maximum revolutions per minute: 6000
  • Starting torque: ≤0.8 Ncm
  • Inertia: ≤25 g cm²
  • Maximum load: 80 N axial/100 N radial
  • Vibration resistance: 10 G (10-2000 Hz)
  • Shock resistance: 50 G (11 ms)
  • Protection degree: IP65
  • Operating temperature: -10 to 80°C
  • Storage temperature: -20 to 80°C
Settable Parameters
  • Steps per revolution
  • Number of revolutions
  • Preset
  • Rotation direction
Diagnostic Functions
  • Position or parameter error
  • Battery alarm
  • Temperature alarm
State Indicators
  • 1 signalling LED for SDCI - Single Drop Communication Interface
See more

Catalog excerpts

MEM-Bus IO-Link Absolute Encoder-1

► ABSOLUTE ENCODERS with IO-Link Interface MEM540B MEM520B MEM620B ► MEM-Bus IO-Link ENCODER PROFILE • Multiturn Absolute Encoders • Conforme a allo standard internazionale IEC 61131-9 • COM3 Communication mode (230,4 kbit/s) ELECTRICAL & OPERATING SPECIFICATIONS MECHANICAL & ENVIRONMENTAL SPECIFICATIONS MEM540B Round clamping flange MEM520B Round synchro flange MEM620B Square flange 63.5x63.5 mm IO-Link communication protocol allows for simplified communication between sensors and Ethernet or fieldbus networks on production lines. IO-Link is a point-to-point protocol, compatible with most industrial fieldbuses, which makes it easily integrable into existing systems. Data transmission, based on a 24V signal, is immune to external interference. The IO-Link protocol ensures: • Accurate data transmission • Easy integration into systems • Automated configuration in case of device replacement • Reduced wiring Multiturn with IO-Link interface, 010 mm solid shaft, round flange ► PROGRAMMING & SETTING O-Link communication is bidirectional (reading and writing), thus allowing the transmission of both cyclic (process) and acyclic data (parameters, error messages, warning, notifications). The IO-Link network consists of an IO-Link Master, IO-Link device and cable (unshielded, up to 20 metres long), with a standardized connector (M12 for MEM40B encoder). Both communication and power are passed through the cable, therefore wiring is very simple. The IO-Link Master and IO-Link devices can be easily configured by means of the Port Configuration Tool: the software identifies the devices connected to the Master and automatically downloads the description files (IODDs) from the online database www.ioddfinder.com IO-Link features the automated configuration; a function of the IO-Link master that stores all parameters of connected devices: in case of encoder replacement, the master reconfigures the device automatically, making maintainance operations easier. • Revolutions number • Rotation direction DIAGNOSTIC FUNCTIONS • Position or parameter error • Battery alarm • Temperature alarm STATE INDICATORS N'4 Fori 05.3 • 1 signalling LED for SDCI - Single Drop Communication Interface * AVAILABLE SHAFT DIAMETERS AVAILABLE SHAFT DIAMETERS AVAILABLE SHAFT DIAMETERS shaft diameter 6mm lenght 10mm shaft diameter 6mm lenght 10mm shaft diameter 6mm lenght 10mm

 Open the catalog to page 1
MEM-Bus IO-Link Absolute Encoder-2

LLAI1 sales network includes several distributors worldwide. Visit our site to find a distributor in your Country. Vi aspettsamo al Padiy'itone 6 SundHOie ABSOLUTE ENCODERS ELAP srl Via Vittorio Veneto, 4 - 20094 Corsico (Mi) tel. +39 02 451.95.61 tax +39 02 45.10.34.06 [email protected] - www.elap.it