1. Catalogs
  2. Ekin Industrial
  3. SUBSTATIONS PRODUCT CATALOGUE
video corpo

SUBSTATIONS PRODUCT CATALOGUE

SUBSTATIONS PRODUCT CATALOGUE
1 / 20 PagesView full catalog

SUBSTATIONS PRODUCT CATALOGUE

Product catalog summary
Introduction
Ekin Endustriyel is a prominent company in the Turkish heating sector, recognized for its innovative and customer-centric approach. Initially focused on exporting plate heat exchangers, the company now produces under the "MIT" brand, complying with ISO Quality Management standards.

MIT Substations
MIT apartment hot water supply stations enhance energy efficiency by integrating central heating systems with independent comfort control. These stations are compact, wall-mountable, and suitable for both new and existing buildings, reducing energy costs and maintaining pressure balance.

System Features
The system replaces the need for a boiler by using heat exchanger units to produce domestic hot water. It includes a compact heat exchanger and a differential pressure control valve, supporting various control paths and easy integration with existing structures.

Technical Parameters
  • Nominal Pressure: PN16
  • Heating Line Temperature: Max. 120°C
  • Min. Domestic Cold Water Pressure: 0.5 Bar
  • Exchanger Material: AISI 316 Stainless Steel
  • Primary Circuit Pressure Loss: 25-35 Kpa


Advantages
MIT hot water stations eliminate the need for hot water recirculation lines, reduce legionella risk, and offer low service costs. They are customizable and compatible with various fuel types.

Working Principle
The system uses a portion of water from the central boiler room to heat water, ensuring constant temperature and flow rate. The design considers flow rates, heating capacity, and reserve tank volume.

Components
  • Heat Exchanger: Facilitates heat transfer between fluids.
  • PM Regulator: Balances water distribution.
  • Differential Pressure Control Valve: Manages pressure differences.
  • Thermostatic Mixing Valve: Maintains constant water temperature.
  • Calorimeter: Measures heat loss for billing and monitoring.


Types
Models MITx D, MITx S, and MITx DY are available, with capacities ranging from 35 kW to 70 kW.

Ekin Academy
Ekin Academy promotes continuous learning and development, offering training programs and collaborating with universities for social responsibility projects.

Sales Team
The sales team is committed to customer satisfaction, providing proactive solutions and upholding high standards of information security and ethics.

Professional System Solution Center Overview
The MIT professional system solution center offers expert support for pumps, heat exchangers, and various systems, including domestic hot water installations, central heating, and industrial cooling systems.

Importance of Proper System Design and Implementation
Correct system design and implementation are crucial for optimal operation and longevity. Technical support is available 24/7.

Commitment to Customer Satisfaction
Ekin is dedicated to sharing knowledge with customers to ensure optimal system performance, aiming to be the best solution partner for heating and cooling applications.

Contact Information
Ekin Endustriyel
Dudullu Organize Sanayi Bölgesi - Des Sanayi Sitesi
107. Sk. B14 Blok No: 2 Ümraniye / İstanbul / Turkey
Phone: +90 216 232 24 12
Fax: +90 216 660 13 08
Email: [email protected]
Website: www.ekinendustriyel.com
See more

Catalog excerpts

SUBSTATIONS PRODUCT CATALOGUE-1

SUBSTATIONS PRODUCT CATALOGUE

 Open the catalog to page 1
SUBSTATIONS PRODUCT CATALOGUE-2

'IE €KiN €NDUSTRiV€l /QrIsitma-Sogutma San. Tic. Ltd. §ti. \ mtl i

 Open the catalog to page 2
SUBSTATIONS PRODUCT CATALOGUE-3

Sustainable Innovation, Quality Standardization and Dynamism Ekin Endustriyel, which has entered Turkish heating sector by exporting of plated heat exchangers, is known with customer focused vision and dynamism. Ekin has expanded into new and upcoming investments. One of the main steps was gaining the identity of being a producer. Ekin has started the production of plate heat exchangers with the brand of "MIT". We have grown in the philosophy of quality, through initially adapting to ISO Quality Management. MIT plate heat exchangers have become a solution for engineering problems in the world...

 Open the catalog to page 3
SUBSTATIONS PRODUCT CATALOGUE-4

HEAT TRANSFER PRODUCTS • Gasketed Plate Heat Exchangers • Brazed Heat Exchangers • Shell&Tube Heat Exchangers • Air Fan Oil Cooler • Economizers • Coils and Radiators PRESSURE VESSELS • Water Heater Tanks • Water Storage Tanks • Buffer Tanks • Expansion Tanks • Stainless Steel Process Tanks • Balance Tanks / Dirt Separators / Air Separators • Pressured Air Tanks • Neutralization Tanks • Air Tubes • Steel IBC Tanks with ADR FOOD GRADE SYSTEMS • Pasteurizers with plate heat exchangers • Hygienic Pasteurizers with Shell & Tube Heat Exchangers • Cheese and whey Systems • UHT - Sterilization Systems...

 Open the catalog to page 4
SUBSTATIONS PRODUCT CATALOGUE-6

MIT SUBSTATIONS MIT apartment hot water supply stations combine the economy provided by central heating systems with the advantage of independently determining the comfort conditions of individual systems. Thus, this system, which significantly reduces energy expenditure, helps to maintain a fair balance in central system fuel expenditures. The MIT apartment hot water supply stations, which are installed in the entrance of the apartment and fed directly from the central hot water boiler, also prevent pressure differences in the apartment heating installation and thus the problems that will arise....

 Open the catalog to page 6
SUBSTATIONS PRODUCT CATALOGUE-7

System Features There is no boiler in the boiler room; instead, the domestic hot water is produced with these heat exchanger units at the entrance of the building. These units include a compact heat exchanger providing instant hot water and a differential pressure control valve that provides a balanced distribution of water between the radiators and the heat exchanger. Different control paths can be monitored in hot water stations Direct: The controls are made only by the differential pressure control elements and by the control valves which are controlled by the programmable thermostats. Technical...

 Open the catalog to page 7
SUBSTATIONS PRODUCT CATALOGUE-8

Advantages • MIT hot water stations eliminate the disadvantages of systems where domestic hot water is obtained by central boiler. For example; hot water recirculation line not to be drawn; and to save different areas of the boiler and pump. • Can be used with any type or combination of fuel used by central systems. • It is sufficient to draw only three pipelines, heating line, heating return line and cold water line. • Eliminates the risk of legionellae due to the fact that water is not stored at the time of need. Savings • Boilers and counters. • Heat Exchanger. • Hot water meter because heating...

 Open the catalog to page 8
SUBSTATIONS PRODUCT CATALOGUE-9

Working Principle While the hot water stations at the entrance are heated by a portion of the water coming from the central boiler room, the other units are the units where the heat exchanger is heated by the water from the hydrophore. Flat entrance stations are primarily domestic hot water and offer more comfortable hot water than boiler systems. Sudden and variable usage provides water at desired flow rate and constant temperature even in hot water demand. The sequence followed in designing the system is as follows; • Flow rate for pump and pipe sizing • Boiler or district heating capacity •...

 Open the catalog to page 9
SUBSTATIONS PRODUCT CATALOGUE-10

Heat Exchanger The heat exchanger located in the station allows the hot water from the central boiler room to be heated through the heat exchanger to heat the water supply and to obtain domestic hot water. Plate Heat Exchangers are the devices that operate according to the principle of heat transfer between two different fluids with temperature difference between them. It is completely separated from each other by the fluid to be heated and the fluid plates to be heated. In hot water station applications, plate heat exchangers are the main equipment in the use of hot water. Thermostatic Mixing...

 Open the catalog to page 10
SUBSTATIONS PRODUCT CATALOGUE-11

When there is any flow rate in the network line, it directs the heating line to the heat exchanger in a proportional manner according to the flow rate. By means of thermostatic control on it, it is possible to set the domestic hot water to a constant temperature and prevent the scald risk and the legionella bacteria in the taps. Calorimeter It calculates the heat loss of the hot water coming from the central boiler room and the heat loss of the heat exchanger in the circle. It is possible to view, bill, or even limit the usage. The bacteria will be prevented. Room Thermostat The motorized valve...

 Open the catalog to page 11
SUBSTATIONS PRODUCT CATALOGUE-12

Product Features MIT the difference in pressure valve DN15 (5-25 kPa) MIT Thermostatic valve DN20 (20-70 °C) with special sensor MIT brazed heat exchanger Isolation of heat exchanger AISI 316 stainless steel piping Galvanized Sheet Equipment That Can Be Added As An Option Protection Cover Ball Valve (DN20) Silt Trap (DN20) Motor Operated Valve (DN20) Place the Calorimeter Assembly Place the Water Meter Assembly Types MIT-1D (35 kW) MIT-2D (45 kW) MIT-3D (55 kW) MIT-4D (60 kW) MIT-5D (65 kW) • MIT-6D (70 kW) MITx S Feature Product Features • MIT Thermostatic valve DN20 (20-70° C) with special...

 Open the catalog to page 12
SUBSTATIONS PRODUCT CATALOGUE-13

Product F • MIT the difference in pressure valve DN15 (5-25 kPa) • MIT Thermostatic valve DN20 (20-70° C) with special sensor • MIT brazed heat exchanger Isolation of heat exchanger • Underfloor heating kit (WILO 15-6) frequency controlled • Circulating pump + Thermostatic valve + Check valve • AISI 316 stainless steel piping • Galvanized Sheet Equipment That Can Be Added As An Option • Protection Cover • Ball Valve DN20 • Silt Trap DN20 • Motor Operated Valve DN20 • Place the Calorimeter Assembly • Place the Water Meter Assembly Types • MIT-1D-Y (35 kW) • MIT-2D-Y (45 kW) • MIT-3D-Y (55 kW)...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.