Catalog excerpts
€KiN €NDUSTRiV€l ENERGY SYSTEMS GENERAL CATALOGUE
Open the catalog to page 1Follow us on social media! www.spotify.com/ekin endustriyel
Open the catalog to page 2The first condition of innovation is to question. And the first condition of sustainable innovation is to question constantly. The journey of innovation has started with a question for us too: “How can we develop value-added technologies in Turkey?”. First turning point in this long journey was the birth of MIT (Made in Turkey) brand. MIT made us the first plate heat exchanger producer of Turkey and it’s founding vision was not to become a local alternative, it was to build a high-quality brand that can compete on a global level. While we are working towards this goal in the past 15 years,...
Open the catalog to page 3PRESSURE VESSELS • Water Heater Tanks • Water Storage Tanks • Buffer Tanks • Expansion Tanks • Stainless Steel Process Tanks • Balance Tanks / Dirt Separators / Air Separators • Vapour Separator • Pressured Air Tanks • Neutralization Tanks • Air Tubes • Steel IBC Tanks with ADR
Open the catalog to page 4Boiler Systems Solar Collectors Water Heater Tanks For Solar
Open the catalog to page 5BOILER SYSTEMS
Open the catalog to page 7In manual-loaded central system hot water boilers produced with MIT brand, Ekin Endustriyel patented "Water Cooled Grating System” is used. In standard boilers in which cast gratings are used, cracking or melting problems may also occur due to excessive heat. These problems constitute change and refurbishment costs for the end user. Thanks to our Water Cooled Grating design, this extra cost is avoided and also boiler efficiency increases due to extra heat transfer surface, fuel cost is lowered. WINDOW TYPE FLAME BREAKER (TURBULATOR) Thanks to window-type turbulators (flame breaker) found in...
Open the catalog to page 8Digital control panel provided on all solid fueled boilers as a standard to our customers; • Adjusting installation water to desired temperature. • Heat tracking with digital display. • Adjusting installation water temperature according to exterior ambient temperature. • Protection against excessive heatings thanks to safety thermostat. • Preventing unnecessary electricity consumption by controlling circulation pump as per installation water temperature are all provided.
Open the catalog to page 9Solid Fueled Three-Pass Automatic Loaded (Stoker) Hot Water Boiler TKOS Series; Three pass, solid fueled, automatic loading (stoker) steel hot water boilers, are specially designed for central heating systems with their long service life with low operating costs. While fuel loading is performed via automatic fuel loading system in TKOS model boilers, burning continues above via spiral. Thanks to special design of spiral loading system, passage of smoke from spiral pipe to bunker is prevented, and an efficient burning is provided. Features • High combustion efficiency up to 85%. • Window...
Open the catalog to page 10Solid Fuel Fired Three-Pass Manual Loaded Hot Water Boiler TKM Series; Fueled manual loaded hot water boilers are manufactured with three-pass. It allows maximum heat transfer and fuel saving by distributing the heat equally obtained through its three-pass design. Combustion air is provided with thermostatically controlled fan. Air obtained from fan located at the rear of boiler is transferred to combustion chamber uniformly. Flame within the burning chamber is transferred to the front side with secondary flow pipes. These hot gases coming to preliminary smoke box are transferred to back...
Open the catalog to page 13Solid Fuel Fired Three-Pass Manual Loaded Room Heater TKS Series; Solid fueled manual room heaters are manufactured as semi-cylindrical and threepass systems. 5 different types of production are made within the range of kcal/h (93 kW) 100,000 kcal/h (kW). Maximum heat transfer and fuel saving are ensured by distributing the heat equally obtained through its threepass design. Since the whole fuel is contacted with fan controlled combustion system, the rate of unburned coal is low. In this way ideal combustion is ensured. Features • High combustion efficiency up to 82%. • Wide combustion...
Open the catalog to page 16Solid Fuel Fired Four-Pass Manual Loaded Room Heater FKSB Series; Solid fueled manual loaded room heaters are manufactured as four-pass systems. 3 different types of production are made within the range of 25.000 kcal/h (29 kW) to 60,000 kcal/h (70 kW). Since the whole fuel is contacted with fan controlled combustion system, the rate of unburned coal is low. Complete burning is performed with secondary air ducts located within combustion chamber. Thanks to its four-pass design, it is designed in a way to burn fuels such as low-calorie domestic coal and wood in a highly efficient and...
Open the catalog to page 19Solid Fuel Fired Four-Pass Full Baffle Manual Loaded Room Heater FKB Series; Solid fueled manual loaded room centrally heated are manufactured as four-pass and full baffle systems. 3 different types of production are made within the range of 60,000 kcal/h (35 kW) to 30,000 kcal/h (70 kW). Since the whole fuel is contacted with fan controlled combustion system, the rate of unburned coal is low. Complete burning is performed with secondary air ducts located within combustion chamber. Thanks to its four-pass baffle (plated) design, it is designed in a way to burn fuels such as , low-calorie...
Open the catalog to page 22Solid Fuel Fired Three-Pass Automated Loaded (Stoker) Room Heater OKS Series; Solid fueled automated loaded room heaters are manufactured as semicylindrical and three-pass systems. 7 different types of production are made within the range of 25.000 kcal/h (29 kW) to 15,000 kcal/h (174 kW). Since the whole fuel is contacted with fan-controlled combustion system, the rate of unburned coal is low. Thanks to its three-pass design, it is designed in a way to burn fuels such as low-calorie domestic coal and wood in a highly efficient and environmentalist way. It allows maximum heat transfer and...
Open the catalog to page 25Solid Fuel Fired Four-Pass Automatic Loaded Room Heater FKSB Series; Solid fueled fully automated loaded room heaters are manufactured as prismatic body baffled and tube bundle four-pass systems. 3 different types of production are made within the range of 30.000 kcal/h (35 kW) to 60,000 kcal/h (70 kW). Since the whole fuel is contacted with fan controlled combustion system, the rate of unburned coal is low. Features • High combustion efficiency up to 82%. • Compatible to burning of nut coal at 10-25 mm sizes. • Wide combustion chamber suitable for coal, lignite coal and wood burning. •...
Open the catalog to page 28All Ekin Industrial catalogs and technical brochures
-
EKİN PRESENTATION 2023
77 Pages
-
GENERAL PRODUCT CATALOGUE 2023
600 Pages
-
CERTIFICATES CATALOGUE
82 Pages
-
SEPARATORS PRODUCT CATALOGUE
22 Pages
-
EXPANSION TANK PRODUCT CATALOGUE
20 Pages
-
AIR TANK PRODUCT CATALOGUE
16 Pages
-
HEAT TRANSFER GENERAL CATALOGUE
108 Pages
-
SUBSTATIONS PRODUCT CATALOGUE
20 Pages
-
HEAT STATIONS PRODUCT CATALOGUE
28 Pages
-
BOILER PRODUCT CATALOGUE
60 Pages
-
FLUID TRANSFER GENERAL CATALOGUE
78 Pages
-
DINO DRUM PUMP PRODUCT CATALOGUE
18 Pages
-
LOBE PUMP PRODUCT CATALOGUE
18 Pages
-
MIT BLOWER PODUCT CATALOGUE
16 Pages
-
VALVE GENERAL CATALOGUE
16 Pages
Archived catalogs
-
GENERAL PRODUCT CATALOGUE 2021
262 Pages