NEXT GENERATION NEXT GENERATION DIGITAL LOAD CELLS DIGITAL LOAD CELLS Robust digital load cells cells Robust digital load Tolerate up to up to 1000% overload Tolerate 1000% overload Accuracy up to up to OIML C6 (MI10) Accuracy OIML C6 (MI10) Easy Easy installation installation Stainless steel steel (IP68) Stainless (IP68) ATEX certified zone zone 21, 22 22 ATEX certified 1, 2, 1, 2, 21, Patented Worldwide Patented Worldwide 中国总代理 Eilersen - Experts in Weighing Since 19691969 Eilersen - Experts in Weighing Since

Open the catalog to page 1
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 2

NEXT GENERATION DIGITAL LOAD CELLS Experts in Weighing since 1969 Since the foundation in 1969, the Eilersen companies in Denmark and Switzerland have been dedicated to the Hygienic Robust Scales ls development, manufacture and supply of high quality robust industrial sensors based on a capacitive measurement principle. This extensive know-how is patented worldwide and invested in the current range of digital load cells. The capacitive technology developed by Eilersen features a number of advantages compared to other technologies used in sensors for measuring force and weight. The Eilersen...

Open the catalog to page 2
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 3

Digital Load Cells and Instrumentation 2000 Generation Load Cells Load cell module MCE2010 Weighing Terminal DeviceNet module Serial module Weighing Terminal Analog module EtherNet/IP module 4000 Generation Load Cells 4000 Generation Modules 24Vdc ATEX 4051A ATEX power supply Weighing Terminals Terminal (LCD) 5024G Next generation digital load cells

Open the catalog to page 3
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 4

Ghost image of digital compression load cell showing ceramic sensor and pcb DIGITAL CAPACITIVE TECHNOLOGY The Choice for Industrial Applications The Eilersen digital capacitive technology is based on a non-contacting ceramic sensor mounted inside the load cell body. As the load cell contains no moving parts and the ceramic sensor is not in contact with the load cell body, the load cell tolerates very high overloads, sideloads, torsion and welding voltages. Therefore, the mechanical installation of the load cell can be done without expensive and complicated mounting kits and overload...

Open the catalog to page 4
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 5

DIGITAL CAPACITIVE TECHNOLOGY (continued...) The True Digital Weighing Solution The electrical installation of the Eilersen digital load cell is pure plug-and-play as the signal from the non-contacting sensor is directly converted, compensated and calibrated by a microprocessor in the load cell to a digital output in grams, kilograms, or Newton. Measurements and status codes are transmitted on the single wire coaxial load cell cable (RG-58) which may be up to 100 meters long. This design results in unsurpassed flexibility, high data rates and allows for connection to a wide range of...

Open the catalog to page 5
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 6

CHOOSE EILERSEN WEIGHING SOLUTIONS Part 1 No.1 Robust Load Cells for Industrial Applications The Eilersen load cells tolerate very high overloads, sideloads and torsion. The load The Eilersen digital load cells can be supplied in very high cells are hermetically sealed (IP68) to ensure superb waterproof protection for tough accuracy (up to OIML C6 MI10) while still maintaining a industrial applications. Furthermore, the load cells are available in capacities up to very high overload tolerance. 500ton. No.2 Simple Mechanical Installation Mechanical protection devices are not necessary when...

Open the catalog to page 6
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 7

Eilersen - Experts in Weighing Since 1969 No.6 Hygienic Installations The simple mechanical installation without overload protection devices ensures hygienic installations with a minimal need for maintenance. No.7 Dynamic Applications The Eilersen digital load cells feature sampling rates of up to 1.000 measurements per second and a deflection of less than 100µm at Rated Capacity. These characteristics result in a high frequency of resonance which together with a wide variety of digital filters makes it possible to achieve a very fast response for dynamic applications. Hygienic weighing...

Open the catalog to page 7
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 8

CHOOSE EILERSEN WEIGHING SOLUTIONS Part 2 No.8 Intelligent Load Cells with Integrated Diagnostics For solutions using the Eilersen digital load cells, it is possible to monitor the load and status of each individual load cell with the integrated diagnostics feature. The Eilersen digital load cells will send an error code if maintenance should be required for fast and easy troubleshooting. Furthermore, a damaged load cell can be exchanged without the need for recalibration. This is an important feature in high capacity applications where it is difficult to find calibration weights....

Open the catalog to page 8
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 9

Electronic modules are available for converting the data output from the All Eilersen load cells are individually calibrated and compensated to Eilersen digital loads cells to a host of standard industrial interfaces ensure that all load cells meet the highest quality standard on the (Profibus DP, DeviceNet, EtherNet/IP, EtherCAT, Modbus, RS485/422, RS232, 4-20mA, 0-10Vdc). The digital technology is optimal for equipment with more than one load cell as several load cells can be connected to a single digital com port and thereby avoiding cabling and analog input cards. Solutions for web...

Open the catalog to page 9
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 10

TYPICAL SYSTEM CONFIGURATION Ribbon cable for load cell bus Input/ Output BNC connectors for load cells Ribbon cable for load cell bus Ribbon cable for load cell bus Start Stop DeviceNet BNC connectors for load cells Profibus DP BNC connectors for load cells Ribbon cable for load cell bus 0 Vdc 24Vdc EtherNet/IP EtherCAT Ribbon cable for load cell bus BNC connectors for load cells BNC connectors for load cells

Open the catalog to page 10
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 11

TYPICAL SYSTEM CONFIGURATION Print Shift Input/ Output EtherNet/IP EtherCAT BNC connectors for load cells DeviceNet MS NS TxDN TxBB D1 Next generation digital load cells

Open the catalog to page 11
Eilersen Digital Load Cells and Weighing Instrumentation - Full Catalogue - 12

TYPICAL SYSTEM CONFIGURATION ATEX Zone Hazardous Area Safe Area Print Shift RS485 Profibus DP DeviceNet EtherNet/IP EtherCAT Safe Area ATEX Zone Hazardous Area Important guidelines for installation in ATEX (Ex) rated area: - Only ATEX certified load cells can be installed in ATEX (Ex) rated area. - Only ATEX certified modules can be used in ATEX (Ex) appplications. - Load cell modules and instrumentation must be placed outside the ATEX (Ex) rated area. - The instrumentation must be supplied by an Eilersen ATEX power supply.

Open the catalog to page 12