Overview: The document describes the Digital Compression Load Cell – Type GDS, which is designed for robust and reliable performance in various applications. It features capacitive technology and a patented sensor that can tolerate up to 400% overload. The load cell is made of stainless steel, hermetically sealed to IP69K, and laser welded to withstand welding voltages and ESD.
Specifications: The load cell supports capacities from 0 to 500 tons and offers high accuracy with a tolerance of 0.25% of Emax. It is pre-calibrated for signals in kg or kN, and calibration is independent of cable length. The cable can be up to 100 meters long and is replaceable.
Applications: The load cell is suitable for level measurement, heavy-duty applications, offshore applications, silo weighing, and process weighing.
Options and Features: The load cell offers various output options including Profibus DP, DeviceNet, Modbus ASCII/RTU, EtherCAT, EtherNet/IP, RS232, RS485/422, 4-20mA, and 0-10V dc. Customized versions are available to meet specific requirements.
Technical Details: The load cell operates within a compensated temperature range of -10 to 50°C and can withstand temperatures from -50 to 70°C (up to 100°C with Teflon cable). It has a maximum deflection at Emax of 0.10 mm and a measuring rate of 200 Hz. The supply voltage is 24Vdc ±10%, and it features an internal resolution of 24 bits.
Material and Protection: Constructed from Stainless Steel 17-4 PH and AISI 316, the load cell is protected to IP68 standards. The standard cable is a 6-meter coaxial RG-58 with a BNC connector, extendable up to 100 meters.
Digital Compression Load Cell – Type GDS 2000 Generation Load Cells Special Features • Robust capacitive technology • Patented high reliability capacitive sensor • High tolerance of up to 400% overload • Stainless steel • Hermetically sealed to IP69K • Laser welded • Withstands welding voltages and ESD • Cable length up to 100meters • Load cell cable replaceable • Pre-calibrated with signal in kg or kN • Calibration independent of cable length • Easy mechanical and electrical installation Applications • Silo weighing • Level measurement • Process weighing • Offshore applications • Heavy duty applications Price Capacity Accuracy Options • Load cell cable length 10, 20, 50 or 100meters • Customized versions available
Open the catalog to page 1Digital Compression Load Cell – Type GDS Dimensions (mm) 2000 Generation Load Cells Rated capacity (Emax) Safe overload limit Safe sideload limit Minimum dead load Temperature effect on zero Temperature effect on sensitivity Compensated temperature range Operating temperature range Deflection at Emax Measuring rate Internal resolution 24 Stainless Steel 17-4 PH and AISI 316 6meter standard coaxial RG-58 (Ø6mm) with BNC connector Maximum cable length 65 / 75** Profibus DP, DeviceNet, Modbus ASCII/RTU, EtherCAT EtherNet/IP, RS232, RS485/422, 4-20mA, 0-10Vdc Output options * with Teflon cable **...