Specifications:
The document describes the design and specifications of DC Analog / DC PNP sensors with a G3/4 design. The sensors are available in two types: Koax probe with 4...20 mA linear output and 2x PNP programmable output. The supply voltage for both types is 20...27 DC, with a current consumption of less than 45 mA. The current output for the analog type is 4...20 mA, while the PNP type has a switching current of 200 mA. Both types have a precision of 5 mm and operate within an ambient temperature range of 0...+70°C and a medium temperature range of 0...+80°C. The sensors are protected under EN 60529 IP 67 standards and are made from materials such as Aluminium, AISI 316 Ti, PTFE, and POM.
Procedures:
The sensors are equipped with an M12 connector for connection. The total length of the sensor is specified by appending 'xxx' to the type, indicating the length in cm. Preferred lengths for GA and GPP types are 300 mm, 500 mm, and 800 mm.
Norms and Standards:
The sensors comply with protection standards EN 60529 IP 67, ensuring they are dust-tight and protected against water immersion.
Recommendations:
It is recommended to use the specified connecting cables (SLG / SLW 3..., SLG / SLW 4...) for optimal performance. Deviations from the specified measuring accuracy can occur depending on installation conditions, particularly in the transition zone.
Key Features:
The sensors offer high precision and easy cleaning, suitable for measuring liquids from oil to water using guided microwave technology. They are part of the MFP series, providing either analog output or 2x PNP output.
See more