Series LDN 1000

Series LDN 1000

Series LDN 1000

Product catalog summary
Overview
The LDN 1009 GAPL is a programmable air flow sensor designed for accurate mass flow measurement of air, particularly in compressed air networks. It features easy installation and configuration via an IO-Link interface, with user levels that can be configured and manipulation detection capabilities.

Application
This sensor detects air flow and temperature in compressed air networks, displaying current air consumption in an easy-to-read format. It can measure air consumption in standard liters or cubic meters.

Functions
  • Selectable displayed measurand and unit of measurement.
  • Configurable outputs.
  • Adjustable reference values for standard pressure and temperature.
  • Programmable and readable TAG ID on the device.
  • IO-Link Device V 1.1 compatibility.

Technical Specifications
  • Detection ranges: Air flow from 0.04 to 15.00 Nm3/h, 0.5 to 250.0 Nl/min, and 0.2 to 65.5 Nm/s; Temperature from 0.0 to 60.0°C.
  • Flow deviations: ±4% from measurement value, ±0.5% from measurement range end value.
  • Reproducibility: ±2%.
  • Temperature deviation: ±2°C.
  • Outputs: PNP-NO/NC, NPN-NO/NC, IO-Link, pulse PNP-NO, Analog 4...20 mA.
  • Supply voltage: 18...30 V DC.
  • Current consumption: ≤120 mA.
  • Switching current: ≤150 mA.
  • Ambient and medium temperature: -10 to +60°C.
  • Start-up time: <10 seconds.
  • Reaction time: <0.3 seconds.
  • Compressive strength: 16 bar.
  • Materials: Aluminium, AISI 304, thermoplast, ceramic, glass coating for sensor; Aluminium, PBT, polyester, AISI 316 Ti for housing.
  • Protection: IP 54 according to EN 60529.
  • Connection: M12 connector.

Installation and Operation
The sensor is installed inline within the pipeline, with run-in and run-out distances determined by existing controls and instruments. It is parameterized using front buttons or the IO-Link interface, with a 6-digit display showing measurement values that can be sent as process data to a PLC.

User Levels and Manipulation Detection
User access can be restricted to modify certain parameters. A non-resettable modification counter registers every reparameterization, ensuring quick and reliable detection of manipulations.

Accessories
  • Mounting plate (72x63x3 Z01217).
  • IOL-Master-Set V1.1 (Z01216).
See more

Catalog excerpts

Series LDN 1000-1

Product innovation Programmable air flow sensor Series LDN 1000 Easy installation - Accurate measurement ■ Mass flow measurement of air ■ Consumption measurement in compressed air networks ■ Easy configuration via lO-Link interface ■ User levels configurable ■ Manipulation detection Application The LDN 1009 GAPL detects air flow and temperature in compressed air networks. It displays current air consumption of a connected tool or system component in an easy-to-read display and responds quickly to any changes in flow speed. At the same time, the sensor can be used to measure air consumed in standard litres or standard cubic metres. Functions • Displayed measurand and unit of measurement selectable • Configurable outputs • Reference values for standard pressure and standard temperature adjustable • TAG ID programmable and readable on device • IO-Link Device V 1.1 Type LDN 1009 GAPL P11373 • G1/4 • 15 Nm3/h Accessories Mounting plate 72x63x3 Z01217 © IO-Link IO-Link is a point-to-point communication interface include enabling parametrization of sensors and actuators using a PC / Notebook and an interconnected master module. Installation The sensor is inserted inline into the pipe line. Any run-in and run-out distances required result from pipe routes and any existing controls and instruments upstream of the sensor. Operation and display The sensor is parametrized using the front buttons or the IO-Link interface. Its 6-digit display shows the measurement values which can be sent as process data to an PLC via the IO-Link connection. User levels The sensor provides the option to restrict the scope of operation of a user group to the modification of certain parameters. Manipulation detection In a non-resettable modification counter, every reparametrization is registered, regardless of whether it was entered via the device buttons or via IO-Link interface. Manipulations are thus detected quickly and reliably. EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com

 Open the catalog to page 1
Series LDN 1000-2

Technical data Detection ranges Air flow Temperature ID-No. Type Flow deviations from measurement value [±%] from measurement range end value [±%] Reproduceability [±%] Temperature deviation 1 [±°C] Supply voltage [V] Current consumption max. [mA] Switching current [mA] Ambient temperature [°C] Medium temperature [°C] Start-up time [s] Reaction time [s] Compressive strength [bar] Sensor material Housing material Display flow Protection [EN 60529] 4 0.5 2 2 PNP-NO/NC, NPN-NO/NC, IO-Link, pulse PNP-NO PNP-NO/NC, NPN-NO/NC, Analog 4...20 mA, reset input for dosage 18...30...

 Open the catalog to page 2

All EGE-Elektronik Spezial-Sensoren GmbH catalogs and technical brochures

  1. Flow Sensors

    120  Pages

  2. SDNC 500

    2  Pages

  3. LDS 1000

    2  Pages

  4. LDV 1000

    2  Pages

  5. AGVU

    1  Page

  6. SDN 550

    1  Page

  7. SCS 440

    1  Page

  8. KBM

    1  Page

  9. Serie cfc

    1  Page

  10. MFP

    1  Page

  11. TGBA

    1  Page

  12. Serie AGVU

    1  Page

  13. Serie HGVH

    1  Page

  14. GK

    104  Pages

  15. Serie IGEXHa

    1  Page

  16. SDNC500

    2  Pages

  17. SNS 552

    2  Pages

  18. LDN 1000

    2  Pages

  19. SDN 500

    2  Pages

  20. Series MFP

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.