Opto high capacity systems

Product catalog summary
Overview: The document provides a comprehensive overview of Opto High Capacity Systems used in automation, focusing on sensors for band-edge control, crack detection, turbidimetry, and positioning. These systems are ISO 9001 certified, ensuring quality and reliability.
System Description: The Opto Edge controller is a crucial component, featuring an amplifier connected to two fiber-optic cables. These cables enable signal transmission and reception through optical converters, allowing precise control and measurement using infrared light for high-speed and accurate process recording, even in challenging environments.
Structure and Functionality: The system can be configured as a photoelectric barrier or using a reflex process. The photoelectric barrier setup involves opposing optical converters, while the reflex process involves converters placed side by side. Both configurations facilitate precise measurement of material insertion depth and detection of cracks or irregularities.
Amplifiers: Various amplifier models are discussed, including the URA 408, URA 5001, and OKZ 550. These amplifiers offer features such as adjustable zero points, amplification, and high pulse rates for rapid process recording. The URA 5001 is noted for its universal applicability, supporting both DC and AC power supplies and offering multiple output options.
Fibre-Optic Cables and Converters: The document details the construction and advantages of fiber-optic cables, which resist electrical and magnetic interference and withstand high temperatures. Optical cross-section converters transform fiber bundles into high-resolution light lines, ensuring stable and precise signal transmission.
Attachment Optics: These components focus infrared radiation and enhance the range and precision of light barriers, particularly useful in high-temperature applications, withstanding temperatures up to 350°C.
Applications and Use Cases: The systems are suitable for various industrial applications, including high-speed material processing and environments with high temperatures or potential explosive hazards. The flexibility and interchangeability of components allow easy adaptation to different requirements.
Technical Specifications: Detailed specifications for various components, including dimensions, temperature ranges, and protection ratings, are provided. The document also includes information on accessories and additional equipment for system enhancement.
Specifications: The document provides details on an optic converter with dimensions 8° x 2° and a mounting clamp model Z00126 designed for optic ULV with a diameter of Ø25.
Procedures: There are no specific procedures outlined in the document.
Standards and Norms: No explicit standards or norms are mentioned.
Recommendations: No recommendations are provided.
Contact Information: The document lists contact details for various international offices and distributors of EGE-Elektronik Spezial-Sensoren GmbH, including locations in Denmark, Sweden, Norway, Finland, France, Italy, Switzerland, Japan, the UK, the Netherlands, Canada, South Africa, Australia, Spain, Taiwan, New Zealand, China, Singapore, Korea, Portugal, Austria, Poland, Turkey, and Slovenia.
See more

Catalog excerpts

Opto high capacity systems-1

■ For band-edge control ■ For band-crack detection ■ Through beam sensors ■ For turbidimetry ■ For positioning

 Open the catalog to page 1
Opto high capacity systems-2

Opto-Sensors Technology and application System description The Opto Edge controller consists of an amplifier (1) to which two fibre-optic cables (2) of up to 10 m in length can be connected via a rapid action coupling. The first fibreoptic cable routes a send signal generated by the amplifier to a first optical converter (3), while the second fibre-optic cable returns a send signal detected by a second optical converter (4) to the amplifier as a receiving signal. This receiving signal is processed further in the amplifier into an output control signal. The Opto Edge controller works with infra-red...

 Open the catalog to page 2
Opto high capacity systems-3

Opto-Sensors Technology and application High capacity amplifier URA 408 Fibre-optic cable and optical converter The fibre-optic cables used are made of glass fibre bundles which are installed in flexible stainless steel tubing or in a metal housing to protect them against environmental influences. They can be subjected to 250 °C and in special applications up to 350 °C. If a high degree of moisture is expected the stainless steel tubing is enclosed in an additional silicon sheath. The greatest advantage of the fibreoptic cable is that it is absolutely insensitive to electrical and magnetic influences,...

 Open the catalog to page 3
Opto high capacity systems-4

Opto-SensorsAnalog high-capacity amplifier Series URA 4...20 mA output 10 kHz detection frequency LCD display EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com

 Open the catalog to page 4
Opto high capacity systems-5

Series URA Outputs 4...20 mA 0...10 V Relay output PNP output Discriminator Fibre-optic cable rapid action coupling EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com

 Open the catalog to page 5
Opto high capacity systems-6

Series ULW Recording width up to 100 mm Ambient temperature up to 200 °C High resolution Recording width B [mm] EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com

 Open the catalog to page 6
Opto high capacity systems-7

Opto-Sensors Band-edge detector Series UBD Light barrier technology Up to 100 mm sensing range Up to 200 mm fork width Light barrier fork L ID-No. Type Fork width A [mm] Mounting breadth M [mm] Fork size L x H [mm] Length of light cable [cm] Temperature range [°C] Detection tolerance [mm] Protection [EN 60529] Material converter Material cable Characteristics 200 – 25...+200 1 IP 54 aIuminium stainless steel Fibre-optic cable rapid coupling required amplifier series URA..., see page 5.04, 5.05 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com

 Open the catalog to page 7
Opto high capacity systems-8

Opto-Sensors High performance through beam sensors Series ULM Range up to 100 m Sensing range [m] Function ID-No. Type Ambient temperature [°C] Field of view [°] EMC-class [mm] Housing material Protection [EN 60529] Connection Receiver P50002 ULME 030 VS – 20...+70 10 A brass-nickel IP 67 5 m PVC-cable 4x0.34 mm2 reqiured amplifier series OKZ 550 GWR, see page 5.10 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.

 Open the catalog to page 8
Opto high capacity systems-9

Opto-SensorsHigh temperature through beam sensors Series ULL To be used with fibre-optic Up to 350 °C With intermediate repeater Fibre-optic amplifier Attachment optics Sensing range [m] required amplifier series OKZ 550 GWR, see page 5.10 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com

 Open the catalog to page 9
Opto high capacity systems-10

Opto-Sensors Amplifier Series OKZ AC-Voltage supply DC-Voltage supply LED indication Cable break and short circuit monitoring ID-No. Type Supply voltage [V] Current consumption [mA] Sensing range Hysteresis Light on / dark on Output Switching current Switching power Switching frequency [Hz] Ambient temperature [°C] EMC-class Protection [EN60529] Function indicator Housing material P50030 OKZ 550 GWR 24 DC / 230 AC 60 / 10 adjustable max. 10% switchable relay with change-over conact max. 4 A / 250 V AC 1000 VA / cos ϕ > 0.7 / L/R < 200 ms 5 – 20...+60 A screw terminals IP 20, housing IP 40 LED...

 Open the catalog to page 10
Opto high capacity systems-11

Type ID-No. Design 1 m fibre-optic cable up to 250 °C 2 m fibre-optic cable up to 250 °C 3 m fibre-optic cable up to 250 °C 5 m fibre-optic cable up to 250 °C 10 m fibre-optic cable up to 250 °C Fibre-optic cable with increased lengths or with protection hose on request. Fibre-optic mounting clamp Air blower for optical converter ULW 100-200, length L=120 mm Air blower for optical converter ULW 50-200, length L=70 mm Mounting clamp for optic ULV EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com

 Open the catalog to page 11
Opto high capacity systems-12

Cematic-Electric B.V. Postbus 777 NL-7550 AT Hengelo Tel. +31 742433422 Fax +31 742913333 ICM Ital Control Meters Srl Via della Valle 67 I-20048 Carate Brianza (Mi) Tel. +39 0362 8052 00 Fax +39 0362 8052 01 Bibus Spain, S. L. Rua do Arroncal, Vial C - Nave 4A ES-36350 Nigran Tel. +34 986 247286 Fax +34 986 209247 Powelectrics Limited Sandy Hill Park, Sandy Way Amington, Tamworth GB-Staffordshire B77 4DU Tel. +44 1827310666 Fax +44 1827310999 Countapulse Controls (PTY) LTD. P.O.B. 40393 ZA-2022 Cleveland Tel. +27 116157556 Fax +27 116157513 Shanghai Beishidetian Business Trade Co., Ltd. 4F, No....

 Open the catalog to page 12

All EGE-Elektronik Spezial-Sensoren GmbH catalogs and technical brochures

  1. Flow Sensors

    120  Pages

  2. SDNC 500

    2  Pages

  3. LDS 1000

    2  Pages

  4. LDV 1000

    2  Pages

  5. AGVU

    1  Page

  6. SDN 550

    1  Page

  7. SCS 440

    1  Page

  8. KBM

    1  Page

  9. Serie cfc

    1  Page

  10. MFP

    1  Page

  11. TGBA

    1  Page

  12. Serie AGVU

    1  Page

  13. Serie HGVH

    1  Page

  14. GK

    104  Pages

  15. Serie IGEXHa

    1  Page

  16. SDNC500

    2  Pages

  17. SNS 552

    2  Pages

  18. LDN 1000

    2  Pages

  19. SDN 500

    2  Pages

  20. Series MFP

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.