Overview
The document provides comprehensive specifications and product information for NH Fuse-Links, which are utilized in industrial applications such as mining and transformer protection. It covers fuse-links with rated voltages from 400 V to 1500 V AC.
Specifications
NH Fuse-Links are available for voltage levels of 400 V, 500 V, 690 V, 1000 V, and 1500 V AC, complying with standards like DIN, VDE, and IEC. The breaking capacity is up to 100 kA for 400 V and 120 kA for 500 V AC.
Features
Key features include twin indicators for fuse status identification, options for live and dead metal gripping lugs, and copper fuse elements for reliable performance. A variety of accessories are available to complement the fuse-links.
Applications
These fuse-links are suitable for cable and line protection in industrial settings, with special applications for semiconductor and DC protection.
Product Range
The document lists NH Fuse-Links with various sizes and amperage ratings, from 000 to 3, and amperage from 2A to 630A, along with order numbers and prices.
Technical Data
Detailed technical data is available, with potential for technical adaptations to meet specific requirements.
Conclusion
EFEN NH Fuse-Links are designed to meet high technical standards, offering reliability and a diverse range of applications in industrial settings.
Additional Specifications
The document also details NH Fuse-Links for AC 500 V and DC 440 V, with utilization categories gG and gL, and breaking capacities of 120 kA (AC) and 25 kA (DC). Special notes include size variations for DC applications.
Properties
Features include twin indicators for gG models, different gripping lugs for gG and gL models, and fuse elements made of copper or pure silver.
Key Models and Pricing
Various models are listed with details such as size, amperage, and pricing, ranging from €3.65 to €97.00 per piece, excluding VAT.
NH Protection Fuse-Link Specifications
Available in amperages from 80A to 315A, with technical adaptations possible.
Technical Data for NH Fuse-Links
Designed for mining applications with pure-silver elements, rated for AC 1000 V, and categorized under gB and aM for specific protections.
Special Designs and Characteristics
Includes designs for AC 1000 and 1500 V, with applications in rectifier-substations for electric railways, featuring dual time-current characteristics and options for micro-switch operation.
Dimensions
Various sizes are available for different applications.
See more

Catalog excerpts

NH Fuse-Links-1

Always the right Fuse-Link NH Fuse-Link 400 V with twin indicator NH Fuse-Links for special industrial applications, e.g. mining industry gTr Fuse-Links for transformer protection NH Fuse-Links up to 1500 V AC

 Open the catalog to page 1
NH Fuse-Links-2

MM: Bild angeben Content NH Fuse-Links AC 400 V gG 20 NH Fuse-Links AC 500 V gG 23 NH Fuse-Links AC 500 V gL 27 NH Fuse-Links AC 690 V gG 31 NH Fuse-Links AC 400 V gTr 33 NH Fuse-Links AC 500 V gR 34 NH Fuse-Links AC 1000 V gB/aM 37 NH Fuse-Links AC 1000/1500 V TF 38 Technical Data see page 40 Features EFEN NH Fuse-Links comply with national and inter-national standards such as DIN, VDE and IEC. The Fuse-Links are available with death metal and live metal gripping lugs. A wide assortment of accessories completes this product-range. System Developed out of its traditional competence, EFEN offers...

 Open the catalog to page 2
NH Fuse-Links-19

36 IN THE LINE OF POWER NH Fuse-Links 500 V gR - Rated voltage: AC 500 V - Utilization category: gR acc. VDE 0636/4 - Application: For protection of semiconductors - Breaking capacity: 120 kA For more information see page 40 35209-0050 NH Maintenance Fuse-Link 500 V gR Properties: - Special marking - dead metal gripping lugs - Fuse element pure silver Description Size Amps Order-No. PU PG Sur. Ag Sur. Cu Price €/pc. NH-ARBEITSSICHERUNG 2 80A GR AC500V LI 2 80 35209-0010 3 N 5 0,023 0,019 38,50 NH-ARBEITSSICHERUNG 2 100A GR AC500V LI 2 100 35209-0020 3 N 5 0,026 0,019 38,50 NH-ARBEITSSICHERUNG...

 Open the catalog to page 19
NH Fuse-Links-23

40 IN THE LINE OF POWER 000 100A 00 160A 1 250A 2 400A 3 630A 0 5 10 15 20 25 30 35 40 45 50 400V 500V New trends in energy distribution are showing higher energy density. More and more components (Fuse-Switches, Fuse-Bases) are installed in smaller cabinets. Cabinets have a limited power acceptance and the space for installation is an important part of the total costs. The main application in energy distribution grids is the 230/400 V voltage rage. EFEN 400 V fuses with lower power dissipation are perfectly fitting to the needs of the actual applications and are also saving energy. The twin...

 Open the catalog to page 23
NH Fuse-Links-25

42 IN THE LINE OF POWER Technical adaptations possible NH Fuse-Links AC 400 V gG Technical data Time-current characteristics for NH Fuse-Links size 000 - 3 gG AC 400 V VDE 0636 T 2 / IEC 60269-2 Cut-off current characteristics for NH Fuse-Links size 000 - 3 gG AC 400 V VDE 0636 T 2 / IEC 60269-2 Ip in kA Ip acc. the prospective short-circuit-current symetrical RMS Ik" Rated current of Fuse-Link In in A Maximum cut-of current iD in kA k = 1,73 (cos 0,1 k = 1 (cos 1)

 Open the catalog to page 25
NH Fuse-Links-29

46 IN THE LINE OF POWER NH Fuse-Links AC 500 V gG Technical data Technical adaptations possible K = 1,73 (cos f 0,1) K=1 (cos f 1) Time-current characteristics for NH Fuse-Links size 00-4a gG AC 500 V VDE 0636 T 2 / IEC 60269-2 Time-current characteristics for NH Fuse-Links size 000 gG AC 500 V VDE 0636 T 2 / IEC 60269-2 Cut-off current characteristics for NH Fuse-Links size 000 - 3 gG AC 500 V VDE 0636 T 2 / IEC 60269-2 Ip in kA Ip acc. the prospective short-circuit-current symetrical RMS Ik" Rated current of Fuse-Link In in A Maximum cut-of current iD in kA

 Open the catalog to page 29
NH Fuse-Links-31

48 IN THE LINE OF POWER NH Fuse-Links AC 500 V gL Technical data For cable and line protection in meshed networks (Resistant to aging) Rated voltage: AC 500 V Utilization category: gL - gG acc. VDE 0636/21 IEC 269-2 Application: for cable and line protection Breaking capacity: 120 kA (Gr. 00-2) Electrical characteristics The time-current characteristics are matched to the line and cable capacities. The lines to be protected can operate at optimal load since breaking in the overload range is slow and quick in case of a short circuit current. The time-current zones acc. to IEC 269-2 guarantee selectivity...

 Open the catalog to page 31
NH Fuse-Links-32

49 IN THE LINE OF POWER NH Fuse-Links AC 500 V gL Technical data Time-current characteristics acc. VDE 0636-2; IEC/EN 60269-2 Power dissipation in W acc. VDE 0636-2; IEC/EN 60269-2 Pre-arcing and operating integrals acc. VDE 0636-2; IEC/EN 60269-2 Cut-offcurrent characteristics acc. VDE 0636-2; IEC/EN 60269-2 Maximum Cut-off current iD in kA Prospective Short-Circuit-Current symetrical RMS Unaffected peak short circuit current IS for Rated current of Fuse-Link iN in A W Size. 00 Size. 1 Size. 2 Size. 3 Total integral acc.to VDE 0636 operating integrals acc.to VDE 0636 A A NH Fuse-Links Size 00...,3...

 Open the catalog to page 32
NH Fuse-Links-34

51 IN THE LINE OF POWER Maximun cut-of current iD in kA Rated current of Fuse-Link iN in A Prospective Short-Circuit Current symmetrical RMS NH Fuse-Links AC 690 V gG Technical data For cable and line protection Time-current characteristics acc. VDE 0636-2; IEC/EN 60269-2 Cut-off current characteristics acc. VDE 0636-2; IEC/EN 60269-2 K = 1,73 (cos f 0,1) K=1 (cos f 1) IP in kA Technical adaptations possible N

 Open the catalog to page 34
NH Fuse-Links-36

53 IN THE LINE OF POWER Maximun cut-of current iD in kA Rated power Sn in kVA NH Fuse-Links AC 400 V gTr Technical data For transformer protection Time-current characteristics acc. VDE 0636-2; IEC/EN 60269-2 Cut-off current characteristics acc. VDE 0636-2; IEC/EN 60269-2 Prospective Short-Circuit Current symmetrical RMS K = 1,73 (cos f 0,1) K=1 (cos f 1) IP in kA Technical adaptations possible N

 Open the catalog to page 36
NH Fuse-Links-38

55 IN THE LINE OF POWER Starting force End force (blown) NH Fuse-Links AC 500 V gR Technical data For protection of semiconductors – Pure silver fuse element Time-current characteristics acc. VDE 0636-2; IEC/EN 60269-2 Force - Distance-Diagram of the striker Cut-offcurrent characteristics acc. VDE 0636-2; IEC/EN 60269-2 Pre-arcing and operating integrals acc. VDE 0636-2; IEC/EN 60269-2 Prospective Short-Circuit Current symmetrical RMS Unaffected peak short circuit current iS for Maximum Cut-off current iD in kA Rated current of Fuse-Link iN in A IP in kA Technical adaptations possible Total integral...

 Open the catalog to page 38
NH Fuse-Links-39

56 IN THE LINE OF POWER Comparison Maintenance Fuse-Link / gG Transmission energy I2t cut-off current ID gG Maintenance Fuse-Link NH Maintenance Fuse-Link Technical data Application: Instead unsing cable and line protection (gG) Fuse-Links, NH Maintenance Fuse-Links are temporary applied during maintance in an power network. NH Maintenance Fuse-Links have an ultra rapid time-current characteristic. Thus the max. cut-off current and the cut-off energy is essentially stronger limited then in NH Fuse-Links of the operational classification gG. Thus meaning for the mechanic less hazard potential...

 Open the catalog to page 39
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.