Catalog excerpts
Powering Production.™ Manual • Automated • Programmable
Open the catalog to page 1OUR STORY Since 1978 EEC has been providing AC Power Sources for the power conversion industry. Our commitment to quality, innovation, and customer service has helped set the expectation for the industry. In 2020 we introduced the 8500 Series Power Source, the world’s highest power density single phase AC Source. As of 2021 we joined the Ikonix Family to become an Ikonix brand, where we continued to innovate and shape the power conversion industry. CUSTOMER HAPPINESS PROMISE We aim to provide an amazing experience and quality testers that last a long time. If you’re not satisfied with your...
Open the catalog to page 2Visit Us Online eecsources.com
Open the catalog to page 3EEC is founded in Taipei City, Taiwan. Introduced the CFC Series AC power source and become the first AC power Source/Inverter professional manufacturer in Taiwan. Introduced the CFC-100W Series Digital AC power sources. The first Ikonix investment in EEC. EEC became the sole manufacturer of Battery Charges for the Taiwan military – General Headquarters of Combined Service Force. Collaboration with Associated Research, Inc. (An Ikonix Brand) to become an ODM partner. Expanded into Suzhou, China and Japan. Introduced the 6300/6400/6500 High Power Switch Mode Power Supplies. Moved the Taipei...
Open the catalog to page 4CAPABILITIES & FEATURES Visit Us Online eecsources.com
Open the catalog to page 5PRODUCT REFERENCE CHART Output Power Capability 500 VA Split 1 Phase (2 Lines/1 Neutral) General Features Frequency Output Range x2 = the number of sources required to achieve an output rating. x3 = the number of sources required to achieve an output rating and
Open the catalog to page 6BROWSE OUR POWER SOURCES Visit Us Online eecsources.com
Open the catalog to page 7RoHS RoHS 2 RoHS 2 3 Programmable AC Power Source The EEC 8500 Series is the most power dense and functionality rich Applicable Industries power source in our history, giving you improved capability, functionality, and a reduced footprint all in one series. This series is manufactured for simulating common grid faults, voltage dips, and other power abnormalities. The 8500 Series provides an output voltage up to 310 VAC and an output frequency ranging from 5 Hz – 1,200 Hz making it the obvious solution for all kinds of applications. Not to mention, an enhanced interface to all models...
Open the catalog to page 8Modes INPUT STANDARD MODE ADVANCED MODE Manual Operation PC Interface (USB/LAN standard, optional GPIB) PowerTRAC Compatibility Voltage, Frequency, Transient, and DC Bias Sweeps Specifications – 8500 8500 SPECIFICATIONS MODEL Power Rating DC, 5 - 1200Hz Full Range Adjust Total Harmonic Distortion (THD)3 ≤ 0.3% @ 50/60Hz (Full Resistive Load) Inrush Current Line Regulation ±0.2V,<1s response time DC OUTPUT Power rating Ripple and Noise (p-p)6 Load Regulation5
Open the catalog to page 9Specifications – 8500 8500 SPECIFICATIONS MODEL SETTINGS Range Start/End Angle Current Hi Limit (OC Fold=OFF) OC Fold Back (OC Fold = ON) OC Fold Back Response Time7 Time unit ± (0.1% + 1 Cycle) at Output frequency ≤ 10Hz/ ± (0.1% + 0.1 s) at Output frequency > 10Hz INPUT
Open the catalog to page 10Specifications – 8500 8500 SPECFICIATIONS MODEL MEASUREMENT Range Voltage(AC) Range Voltage(DC) ± (1% of reading +10 counts) at PF ≥ 0.35 and voltage > 5V ± (2% of reading +15 counts) at PF ≥ 0.35 and voltage > 5V ± (1% of reading +5 counts) at PF ≥ 0.35 and voltage > 5V ± (1% of reading +10 counts) at PF ≥ 0.35 and voltage > 5V ± (1% of reading +20 counts) at PF ≥ 0.35 and voltage > 5V Range Power Factor W/VA, Calculated and displayed to three significant digits Range Power Apparent (VA) Calculated Formula Crest Factor Measurement Range Reactive Power Measurement Calculated Formula Peak...
Open the catalog to page 11Specifications – 8500 8500 SPECFICIATIONS MODEL GENERAL PLC Remote Control Rear Input Input:Output ON, Output OFF/Reset, Output Verify, Interlock,File Recall M1 through M7, Trigger Output: Fail, Test-in-Process AC Outlet Terminal Block 100 x 100 (file x sequence) / MANUAL, STEP, PULSE only 100 file no sequence Sync Signal/ Ext Trigger 10 x 100 (file x sequence) / MANUAL only 10 file no sequence ON / START / END / BOTH / OFF / EVENT, Output Signal 5V ,BNC type Standard USB, PLC remote, LAN, Analog / Option GPIB, RS-232 Complies with the requirements of the following directive and standards....
Open the catalog to page 123 Phase AC Power Sources With a unique feature set and competitive price point, our 400XAC RoHS RoHS 2 RoHS 2 3 COMPLIANT COMPLIANT Applicable Industries Series provides 3Ø AC power in a single box. Our exclusive SmartCONFIG feature allows you to switch from 1Ø to 3Ø or DC output with the push of a button. This maximizes your investment while giving you the AC power that your application needs. The 400XAC Series consists of two models: the 430XAC is a 3 kVA AC power source and GUARANTEED SHIPMENT Features ■ Exclusive SmartCONFIG feature allows for push button switch of 1Ø, 3Ø, or DC output....
Open the catalog to page 13Power Rating 1Ø2W Inrush Current (peak) THD (Total Harmonic Distortion) <0.5% (Resistive Load) at 40.0~70.0 Hz and output voltage within the 80~140 VAC at Low Range or the 160~280 VAC at High Range. <1% (Resistive Load) at 70.1~1000 Hz and output voltage within the 80~140 VAC at Low Range or the 160~280 VAC at High Range. Crest Factor Line Regulation Load Regulation (Hardware) ± (1% of output +1 V) at Resistive Load, <400 µS response time Load Regulation (Software) Poly-phase mode (3Ø4W) for per phase output setting Voltage Frequency Starting & Ending Phase Angle 5.0~300 VAC (phase),...
Open the catalog to page 14Specifications – 400XAC Poly-phase mode (3Ø4W) for per phase measurement Range ± (1% of reading +5 counts) at 501-1000 Hz, CF <1.5 and Current (peak) ≤3.6 A ± (1% of reading +5 counts) at 501-1000 Hz, CF <1.5 and Current (peak) ≤7.2 A ± (1% of reading +5 counts) at 501-1000 Hz, CF <1.5 and Current (peak) ≤27.6 A ± (1% of reading +5 counts) at 501-1000 Hz, CF < 1.5 and Current (peak) ≤55.2 A Range Current (peak) ± (1% of reading + 5 counts) at 40.0-70.0 Hz ± (1.5% of reading + 10 counts) at 70.1 - 500 Hz ± (1.5% of reading + 10 counts) at 501 - 1000 Hz and CF <1.5 Range ± (2% of reading +30...
Open the catalog to page 15All EEC catalogs and technical brochures
-
EEC Product Reference Chart
1 Pages