8500 Series - Programmable AC Power Source
5Pages

{{requestButtons}}

Catalog excerpts

8500 Series - Programmable AC Power Source - 1

RoHS RoHS 2 RoHS 2 3 Programmable AC Power Source The EEC 8500 Series is the most power dense and functionality rich Applicable Industries power source in our history, giving you improved capability, functionality, and a reduced footprint all in one series. This series is manufactured for simulating common grid faults, voltage dips, and other power abnormalities. The 8500 Series provides an output voltage up to 310 VAC and an output frequency ranging from 5 Hz – 1,200 Hz making it the obvious solution for all kinds of applications. Not to mention, an enhanced interface to all models completely designed with the enduser in mind. Our 8500 Sources can be configured as a simple AC Power Source in Standard mode or, as an upgraded option, Programmable mode. Programmable mode adds the benefits of a sweep of voltage, frequencies, transients, and DC bias over the course of a single sequence or several different tests. The 8500 Series includes the following models: 8505, 8512, 8520, 8530, 8540, & 8560. System Integrator ■ With expanded output voltage to 310VAC and output frequency from 5Hz to 1200Hz, the 8500 provides a single, simple solution to meet a wide variety of testing applications. ■ Advanced mode option allows you to easily simulate voltage surges, voltage drops, voltage pulses, voltage sweeps, DC bias, and frequency sweeps to help make meeting the specific needs of your testing application easier than it has ever been. ■ High power density with a reduced overall footprint offers you the flexibility you need to use your 8500 Series power source in either a bench top or rack mount application. ■ Legacy Mode allows you to keep your command set from your 6000, 7000, or 300XAC series. GUARANTEED SHIPMENT abnormal condition on your DUT by simply selecting the waveform you would like to output. ■ 4 pre-configured waveforms allow you to simulate nearly any 1 USB/RS-232 Interface Ethernet Interface Options GPIB Interface Start Output START TEST DRIVER AVAILABLE

Open the catalog to page 1
8500 Series - Programmable AC Power Source - 2

Modes INPUT STANDARD MODE ADVANCED MODE Manual Operation PC Interface (USB/LAN standard, optional GPIB) PowerTRAC Compatibility Voltage, Frequency, Transient, and DC Bias Sweeps Specifications – 8500 8500 SPECIFICATIONS MODEL Power Rating DC, 5 - 1200Hz Full Range Adjust Total Harmonic Distortion (THD)3 ≤ 0.3% @ 50/60Hz (Full Resistive Load) Inrush Current Line Regulation ±0.2V,<1s response time DC OUTPUT Power rating Ripple and Noise (p-p)6 Load Regulation5

Open the catalog to page 2
8500 Series - Programmable AC Power Source - 3

Specifications – 8500 8500 SPECIFICATIONS MODEL SETTINGS Range Start/End Angle Current Hi Limit (OC Fold=OFF) OC Fold Back (OC Fold = ON) OC Fold Back Response Time7 Time unit ± (0.1% + 1 Cycle) at Output frequency ≤ 10Hz/ ± (0.1% + 0.1 s) at Output frequency > 10Hz INPUT

Open the catalog to page 3
8500 Series - Programmable AC Power Source - 4

Specifications – 8500 8500 SPECFICIATIONS MODEL MEASUREMENT Range Voltage(AC) Range Voltage(DC) ± (1% of reading +10 counts) at PF ≥ 0.35 and voltage > 5V ± (2% of reading +15 counts) at PF ≥ 0.35 and voltage > 5V ± (1% of reading +5 counts) at PF ≥ 0.35 and voltage > 5V ± (1% of reading +10 counts) at PF ≥ 0.35 and voltage > 5V ± (1% of reading +20 counts) at PF ≥ 0.35 and voltage > 5V Range Power Factor W/VA, Calculated and displayed to three significant digits Range Power Apparent (VA) Calculated Formula Crest Factor Measurement Range Reactive Power Measurement Calculated Formula Peak...

Open the catalog to page 4
8500 Series - Programmable AC Power Source - 5

Specifications – 8500 8500 SPECFICIATIONS MODEL GENERAL PLC Remote Control Rear Input Input:Output ON, Output OFF/Reset, Output Verify, Interlock,File Recall M1 through M7, Trigger Output: Fail, Test-in-Process AC Outlet Terminal Block 100 x 100 (file x sequence) / MANUAL, STEP, PULSE only 100 file no sequence Sync Signal/ Ext Trigger 10 x 100 (file x sequence) / MANUAL only 10 file no sequence ON / START / END / BOTH / OFF / EVENT, Output Signal 5V ,BNC type Standard USB, PLC remote, LAN, Analog / Option GPIB, RS-232 Complies with the requirements of the following directive and standards....

Open the catalog to page 5