400XAC - 3 Phase AC Power Source
6Pages

{{requestButtons}}

Catalog excerpts

400XAC - 3 Phase AC Power Source - 1

3 Phase AC Power Sources With a unique feature set and competitive price point, our 400XAC RoHS RoHS 2 RoHS 2 3 COMPLIANT COMPLIANT Applicable Industries Series provides 3Ø AC power in a single box. Our exclusive SmartCONFIG feature allows you to switch from 1Ø to 3Ø or DC output with the push of a button. This maximizes your investment while giving you the AC power that your application needs. The 400XAC Series consists of two models: the 430XAC is a 3 kVA AC power source and GUARANTEED SHIPMENT Features ■ Exclusive SmartCONFIG feature allows for push button switch of 1Ø, 3Ø, or DC output. Options GPIB Interface Ethernet Interface ■ Single phase input power requirements. ■ 50 built-in memory locations with 9 test steps. ■ Built-in power factor correction (PFC). ■ Advanced metering circuits monitor voltage, current, peak current, power, apparent power, reactive power, power factor, and crest factor. ■ External voltage sensing for accurate metering. ■ Transient feature simulates voltage variations, brownouts, and transient voltage conditions. ■ Programmable starting and ending angle of the output sine wave. ■ Rack mount handle kit included. Start Output START TEST DRIVER AVAILABLE

Open the catalog to page 1
400XAC - 3 Phase AC Power Source - 2

Power Rating 1Ø2W Inrush Current (peak) THD (Total Harmonic Distortion) <0.5% (Resistive Load) at 40.0~70.0 Hz and output voltage within the 80~140 VAC at Low Range or the 160~280 VAC at High Range. <1% (Resistive Load) at 70.1~1000 Hz and output voltage within the 80~140 VAC at Low Range or the 160~280 VAC at High Range. Crest Factor Line Regulation Load Regulation (Hardware) ± (1% of output +1 V) at Resistive Load, <400 µS response time Load Regulation (Software) Poly-phase mode (3Ø4W) for per phase output setting Voltage Frequency Starting & Ending Phase Angle 5.0~300 VAC (phase),...

Open the catalog to page 2
400XAC - 3 Phase AC Power Source - 3

Specifications – 400XAC Poly-phase mode (3Ø4W) for per phase measurement Range ± (1% of reading +5 counts) at 501-1000 Hz, CF <1.5 and Current (peak) ≤3.6 A ± (1% of reading +5 counts) at 501-1000 Hz, CF <1.5 and Current (peak) ≤7.2 A ± (1% of reading +5 counts) at 501-1000 Hz, CF <1.5 and Current (peak) ≤27.6 A ± (1% of reading +5 counts) at 501-1000 Hz, CF < 1.5 and Current (peak) ≤55.2 A Range Current (peak) ± (1% of reading + 5 counts) at 40.0-70.0 Hz ± (1.5% of reading + 10 counts) at 70.1 - 500 Hz ± (1.5% of reading + 10 counts) at 501 - 1000 Hz and CF <1.5 Range ± (2% of reading +30...

Open the catalog to page 3
400XAC - 3 Phase AC Power Source - 4

Specifications – 400XAC Single-phase mode (1Ø2W) Setting Frequency 460XAC 40~1000 Hz Full Range Adjust Accuracy Starting & Ending Phase Angle Accuracy 5V~150V Current Hi Limit OC Fold Back Response Time Single-phase mode (1Ø2W) measurement Frequency 0 - 1.000 W / VA, Calculated and displayed to three significant digits Accuracy Power Reactive (Q) Crest Factor 0 VAR~7800 VAR √(VA)² - (W)², Calculated value Ap / A, Calculated and displayed to two significant digits Poly-phase mode (1Ø3W) for per phase output setting Voltage ± (2% of reading +5 counts) at 40.0~500 Hz and PF ≥0.2 ± (2% of...

Open the catalog to page 4
400XAC - 3 Phase AC Power Source - 5

Specifications – 400XAC Poly-phase mode (1Ø3W) for per phase measurement Range Current (peak) 0.0 A~76.0 A ± (1% of reading + 5 counts) at 40.0-70.0 Hz ± (1.5% of reading + 10 counts) at 70.1-500 Hz ± (1.5% of reading + 10 counts) at 501-1000 Hz and CF <1.5 ± (2% of reading +15 counts) at 40.0-500 Hz and PF ≥0.2 ± (2% of reading +30 counts) at 501-1000 Hz and PF ≥0.5 ± (2% of reading +5 counts) at 40.0-500 Hz and PF ≥0.2 ± (2% of reading +15 counts) at 501-1000 Hz and PF ≥0.5 Power Factor Crest Factor W / VA, Calculated and displayed to three significant digits 0-10.00 Ap / A, Calculated...

Open the catalog to page 5
400XAC - 3 Phase AC Power Source - 6

Specifications – 400XAC DC MEASUREMENT Voltage Over Current 110% of full rated current >1 second Output Short Shut Down Speed When over Power 105 ~ 110% of full power >5 second. When over Power >110% of full power <1 second. Temperature over 95 degree C on the power amp and PFC heatsink Temperature over 120 degree C on the power amp and PFC heatsink When output frequency < 100Hz, maximum voltage deviation + 5V L When output frequency 101-500Hz, maximum voltage deviation + 15V When output frequency 501-1000Hz, maximum voltage deviation + 20V When output frequency < 100Hz, maximum voltage...

Open the catalog to page 6