Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of ATEX rotary vane pumps, specifically Group 2 Category 2 and 3. It highlights the importance of adhering to safety warnings to prevent damage and ensure safe operation. The pumps are designed to meet ATEX requirements for use in potentially explosive atmospheres, classified under Group II Category 2 for external ignition sources and Category 3 for internal sources. They are oil-sealed, sliding vane, high vacuum pumps suitable for laboratory and industrial use, featuring an inlet valve to prevent oil back migration and driven by ATEX-approved flameproof motors. The pumps are certified for use in explosive atmospheres, suitable for gas groups IIA, IIB, and IIC.

Normal and Abnormal Operation

The manual outlines conditions for normal operation, including correct electrical connections and safety interlocks, ensuring safe use in specified gas atmospheres. Prohibited uses include operating in higher ATEX category zones, using as a positive pressure compressor, and operating under high back pressure or reverse rotation.

System Data

Includes physical, mechanical, and electrical data such as dimensions, mass, noise, vibration, and specific electrical data for single-phase and three-phase pumps.

Installation

Details safety precautions and procedures for mechanical and electrical installation, including motor configuration and connection to electrical supply. Installation must be performed by skilled technicians familiar with vacuum equipment, maintaining positive pressure in the pump oil box and using inert gas purges for ATEX compliance.

Operation

Covers procedures for pumping flammable materials, gas purges, shutdown, and manual reset. Emphasizes the need for leak-tight systems and the use of inert gas purges to prevent condensation of flammable vapors.

Maintenance

Provides safety information, maintenance plans, and control intervals for ATEX coupling inserts. Maintenance is crucial for ATEX certification, requiring the system to cool and be isolated from electrical supply before maintenance. Weekly checks include ensuring secure cable glands, clean motor fan cowls, and sufficient oil levels.

Service and Spares

Information on service and spare parts is provided, with instructions for returning equipment. Standard maintenance kits are referenced in individual manuals, and additional spares can be obtained from Edwards.

Technical Data

Includes tables with torque settings for various pump components and specifies maintenance intervals for ATEX coupling inserts. It also provides electrical, mechanical, and noise data relevant to the pumps.

See more

Catalog excerpts

RV ATEX Rotary Vane Pumps-1

Instruction Manual ATEX Rotary Vane Pumps Motor Description

 Open the catalog to page 1
RV ATEX Rotary Vane Pumps-2

This page has been intentionally left blank.

 Open the catalog to page 2
RV ATEX Rotary Vane Pumps-3

Manor Royal, declare under our sole responsibility that the product(s) RV3. RVS, RV8. RV12 ATEX rotary vacuum pumps Pump type Motor description to whkh this declaration relates is in conformity with the following standard(s) or other normative documents) Safety of machinery. Basic Concepts. General Principals for Design. Safety Requirements for Electrical Equipment for Measuromsnt. Control and laboratory use. General Requirements. Compressors and Vacuum Pumps - Safety Requirements. Part 2: Vacuum Pumps. Non Electrical Equipment for Potentially Explosive Atmospheres. Electrical Apparatus for Potentially...

 Open the catalog to page 3
RV ATEX Rotary Vane Pumps-4

Manor Royal. declare under our sote responsibility that the produ«(s) E1M175, E2M175. E1M27S & E2M27S ATEX Rotary Vacuum Pumps Pump type Variant Motor description to which this declaration relates is in conformity with the following standard(s) or other normative documcni(s) EN ISO 12100-2: 2003 Safety of Machinery - Basic Concepts. General principles for Design. EN 13463-1: 2001 Non Electrical Equipment for Potentially Explosive Atmosphères. EN 50014:1992 Electrical Apparatus for Potentially Explosive Atmospheres - General Requirements. EN 60034-1:1999 Rotating Electrical Machines - Rating &...

 Open the catalog to page 4
RV ATEX Rotary Vane Pumps-5

Manor Royal. declare under our sole responsibility that the product(s) E1M40. E2M40. E1M80 & E2M80 ATEX rotary vacuum pumps Pump type Variant Motor description to which this declaration relates is in conformity with the following sundard(s) or other normative documents) Safety of Machinery - Basic Concepts. General principles for Design. Non Electrical Equipment for Potentially Explosive Atmospheres. Electrical Apparatus for Potentially Explosive Atmospheres - General Requirements. Rotating Electrical Machines - Rating & Performance Non-electrical equipment for potentially explosive atmospheres-...

 Open the catalog to page 5
RV ATEX Rotary Vane Pumps-6

Manor Royal. declare under our sole responsibility that the product(s) E1M18 & E2M18 ATEX Rotary Vacuum Pumps to which this declaration relates is in conformity with tho following standard(s) or other normative documcw(s) Safety of machinery. Basic Concepts. General Principals for Design. Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory use. General Requirements. Compressors and Vacuum Pumps - Safety Requirements. Pirt 2: Vacuum Pumps. Non Electrical Equipment for Potentially Explosive Atmospheres. Electrical Apparatus for Potentially Explosive Atmospheres...

 Open the catalog to page 6
RV ATEX Rotary Vane Pumps-7

Manor Royal, declaro under our sole responsibility that the product(s) E1M18 & E2M18 ATEX Rotary Vacuum Pumps Purr© type MOCO* dWC/ipOOn 986 = IlSv Iph 60Hi EExd IIC 993 - 400v 3ph 5CHi EExd HC to which this declaration relates is in conformity with the following sundard(s) or other normative documenti^) Safety of machinery. Basic Concepts. General Principals for Design. Safety Requirements for Electrical Equipment for Measurermnt. Control and Laboratory use. General Requirements. Compressors and Vacuum Pumps - Safety Requirements, Part 2: Vacuum Pumps. Non Electrical Equipment for Potentially...

 Open the catalog to page 7
RV ATEX Rotary Vane Pumps-8

Manor Royal. declare under our sole responsibility that the product(s) RV3, RV5. RV8. RV12 ATEX rotary vacuum pumps Pump type Motor description to which this declaration relates is in conformity with the following standard(s) or other normativo documom(s) Safety of machinery. Basic Concepts. General Principals for Design. Safety Requirements for Electrical Equipment for Measurement. Control and Laboratory use. General Requirements. Compressors and Vacuum Pumps - Safety Requirements. Part 2: Vacuum Pumps. Non Electrical Equipment for Potentially Explosive Atmospheres. Electrical Apparatus for...

 Open the catalog to page 8
RV ATEX Rotary Vane Pumps-9

Section Page For return of equipment, complete the HS Forms at the end of this manual. © Edwards Limited 2008. All rights reserved. Page i Edwards and the Edwards logo are trademarks of Edwards Limited.

 Open the catalog to page 9
RV ATEX Rotary Vane Pumps-10

Table Page Associated publications Publication title Publication number Vacuum pump and vacuum system safety P300-20-000 Vacuum systems safety booklet P400-40-100 British Autoguard Samiflex coupling installation/maintenance instructions Flameproof motor maintenance instructions © Edwards Limited 2008. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.

 Open the catalog to page 10
RV ATEX Rotary Vane Pumps-11

This manual provides installation, operation and maintenance instructions for Group 2 Category 2 ATEX pumps in —■. respect to ignition sources external to the pump and Group 2 Category 3 ATEX pumps in respect to ignition sources Q internal to the pump. You must use the pumps as specified in this manual. ^ Read this manual before you install and operate your rotary vacuum pump. Important safety information is highlighted as WARNING and CAUTION instructions; you must obey these instructions. The use of WARNINGS and CAUTIONS is defined below. Warnings are given where failure to observe the instruction...

 Open the catalog to page 11
RV ATEX Rotary Vane Pumps-12

When flammable materials are present within the equipment you must: • Not allow air to enter the equipment. • Ensure the system is leak tight. • Use an inert gas purge (for example, a nitrogen purge to dilute any flammable gases or vapours entering the pump inlet, and/or use an inert gas purge to reduce the concentration of flammable gases or vapours in the pump and in the exhaust pipeline to less than one quarter of the gases, published Lower Explosive Limits See Section 6.5 of the safety booklet P400-40-100 for details on how to avoid the flammable zone. Edwards pumps are not intended for use...

 Open the catalog to page 12
RV ATEX Rotary Vane Pumps-13

Table 1 - ATEX certification The elements of this certification have the following meaning: - Equipment to be used in a potentially explosive atmosphere - Equipment group II - non mining equipment - Where explosive atmospheres caused by gases, vapours or mists are concerned - Protection by constructional safety - Suitable to pump gas group MB - Suitable for use within MB or IIC explosive atmospheres - Auto ignition temperature of gas, that is T3 (200 °C), T4 (135 °C), T160 (160 °C) © Edwards Limited 2008. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.

 Open the catalog to page 13

All EDWARDS catalogs and technical brochures

  1. SPEEDIVALVE

    2  Pages

  2. GV

    12  Pages

  3. XDD1

    2  Pages

  4. PGC

    2  Pages

  5. 8200

    2  Pages

  6. IS 320FX

    2  Pages

  7. RGA

    8  Pages

  8. EH

    2  Pages

  9. RV

    8  Pages

  10. nXDS

    12  Pages

  11. XDS series

    4  Pages

  12. T-STATION 85

    2  Pages

  13. AIM

    2  Pages

  14. WRG

    2  Pages

  15. ASG2

    2  Pages

  16. ELD500

    8  Pages

  17. iXH Dry Pumps

    2  Pages

  18. RV Pumps

    8  Pages

  19. Small EM Pumps

    12  Pages

  20. GXS Dry Pumps

    20  Pages

  21. EDP Pumps

    4  Pages

  22. CXS Dry Pumps

    12  Pages

  23. ADC Datasheet

    4  Pages

  24. nEXT Brochure

    12  Pages

  25. CXS Dry Pump

    9  Pages

  26. EV Brochure

    6  Pages

  27. Spectra G

    4  Pages

  28. iGX Dry Pumps

    4  Pages

  29. T-Station 75

    2  Pages

  30. EXT75-255DX

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.