Overview: Edwards Vacuum offers two variants of Residual Gas Analyzers (RGA): PRA and WRA. Both models ensure high performance and efficiency with simple operation. The PRA models are designed for accessibility and performance, available in four variants to meet different process needs. The WRA models are top-of-the-line, offering market-leading specifications and increased sensitivity for greater measurement accuracy.
Specifications:
  • PRA Models: Available in variants PRA100, PRA100S, PRA200, and PRA200S with mass ranges of 1-100 or 1-200 amu. They feature a QMS mass filter type, Faraday cup or EM/Faraday cup detectors, and sensitivity of 1x10-5 A/mbar or 400/1x10-5 A/mbar. Minimum detectable partial pressure is 1x10-10 mbar or 1x10-14/1x10-10 mbar.
  • WRA Models: Available in variants WRA200S and WRA300S with mass ranges of 1-200 or 1-300 amu. They feature QMS mass filter type, EM/Faraday cup detectors, and sensitivity of 400/2.5x10-4 A/mbar. Minimum detectable partial pressure is 1x10-15/1x10-11 mbar.
Features and Benefits:
  • Full Ethernet Protocol for direct PLC connection.
  • Dedicated software for real-time process tracking and detailed analysis of up to 16 units.
  • On-board display for main gas types and system pressure.
  • Customer replaceable parts and degas function.
  • Protection of Ion source and EM.
Applications:
  • PRA: High vacuum pumping equipment, R&D, freeze drying, PV/FPD/Semi gas analysis.
  • WRA: UHV pumping equipment, organic material analysis, environmental tracking, gas impurity analysis.
Technical Data: Both models operate at a maximum pressure of 1x10-4 mbar, with an operating temperature of 40°C and a maximum analyzer temperature of 120°C for PRA and 250°C for WRA. They use Ir/Y2O3 filament material and have a power input of DC24V ±10% 50W.
Ordering Information: Various order numbers are provided for different models and components, such as analyzer tubes, filament kits, and ion sources.
See more

Catalog excerpts

PRA & WRA RESIDUAL GAS ANALYSERS (RGA)-1

PRODUCT DATA SHEET Our new RGA includes two variants: PRA & WRA, both come with simple and effective operation assuring high performance and efficiency. Edwards PRA RGAs deliver the perfect balance of high end performance and accessibility. Available in four variants to suit your process needs, whether you just need a basic model or something with more sensitivity/range, the PRA is the perfect starting point for analysing your processes. The WRA RGAs from Edwards are our top of the line models, with market leading specifications. Available in two variants 1-200 or 1-300 amu, you can measure a wide range of gasses/by-products from your processes. This is paired with increased sensitivity compared to the PRA to allow for greater accuracy from your measurements. All RGAs have full Ethernet Protocol, which allows you to connect directly to your own PLC and are equipped with dedicated, easy-to-use software which allows you to track your process in real-time from your laptop and do detailed analysis of up to 16 different units. For those wanting a snapshot view, the units have a unique on-board display which can show you the main gas types as well as the overall pressure of your system without having to connect via laptop. FEATURES AND BENEFITS • Total pressure measurement • Dual filament • On unit display • Customer replaceable parts • Degas function • Protection of Ion source and EM • Residual gas analysis in high vacuum pumping equipment • Residual gas analysis in UHV pumping equipment • Analysis of organic materials • Gas analysis in Freeze drying • Environmental tracking

 Open the catalog to page 1
PRA & WRA RESIDUAL GAS ANALYSERS (RGA)-2

PRODUCT DATA SHEET TECHNICAL DATA AND ORDERING INFORMATION PRA100 Mass filter type Detector type Sensitivity (A/mbar) Minimum detectable partial pressure (mbar) Max operating pressure (mbar) Filament material Max bake out temp (elec removed) (°C) Power input Connection flange IP Serial communication Resolution Mass filter type WRA-S analyzer tube Max bake out temp (elec removed) (°C) Detector type Sensitivity (A/mbar) Minimum detectable partial pressure (mbar) Max operating pressure (mbar) Filament material Connection flange Power input IP Serial communication Resolution Product description Order...

 Open the catalog to page 2

All EDWARDS catalogs and technical brochures

  1. SPEEDIVALVE

    2  Pages

  2. GV

    12  Pages

  3. XDD1

    2  Pages

  4. PGC

    2  Pages

  5. 8200

    2  Pages

  6. IS 320FX

    2  Pages

  7. RGA

    8  Pages

  8. EH

    2  Pages

  9. RV

    8  Pages

  10. nXDS

    12  Pages

  11. XDS series

    4  Pages

  12. T-STATION 85

    2  Pages

  13. AIM

    2  Pages

  14. WRG

    2  Pages

  15. ASG2

    2  Pages

  16. ELD500

    8  Pages

  17. iXH Dry Pumps

    2  Pages

  18. RV Pumps

    8  Pages

  19. Small EM Pumps

    12  Pages

  20. GXS Dry Pumps

    20  Pages

  21. EDP Pumps

    4  Pages

  22. CXS Dry Pumps

    12  Pages

  23. ADC Datasheet

    4  Pages

  24. nEXT Brochure

    12  Pages

  25. CXS Dry Pump

    9  Pages

  26. EV Brochure

    6  Pages

  27. Spectra G

    4  Pages

  28. iGX Dry Pumps

    4  Pages

  29. T-Station 75

    2  Pages

  30. EXT75-255DX

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.