Product Overview: The Edwards Active Thermocouple (ATC-E) gauges are compact, stand-alone vacuum transducers that mount directly on the thermocouple tube. They feature integrated drive electronics, simplifying system design and saving rack space. The gauges operate with a wide-range, regulated internal power supply, compatible with standard DC power supplies (+20 to +36 V), and are tolerant to voltage fluctuations.
Specifications: The ATC-E electronics module supports both medium and low-pressure gauge tubes, offering a cost-effective solution for higher pressures. It operates from a power supply range of +13.5 to +36 V DC with a maximum power consumption of 0.54 W. The output signal ranges from 2 to 10 V DC, with fault output between 0 to 2 V DC and 10 to 13.5 V DC. The module features low output impedance and an integral Faraday shield for noise immunity, allowing cable runs up to 100 meters.
Features and Benefits: The gauges provide a standard analogue output (0 to +10 V DC) and gauge identifier, facilitating easy interfacing with computers or PLCs. They include an adjustable set-point with a vacuum status LED for process control and interlocking, and a digital vacuum status signal. The ATC-D gauge covers a pressure range from 50 to 5 x 10-2 Torr, while the ATC-M covers from 1 to 10-3 Torr.
Technical Data: The ATC-E module has an operating/storage temperature range of +5 to +60 / +0 to +70 °C and weighs 110 g. It includes an 8-way FCC68/RJ45 socket for external interface connection. The electronic design complies with EN61010-1 standards, and the electromagnetic compatibility meets EN61326 (Class B Emissions). The casing is flame retardant (UL94).
Ordering Information: The product range includes the ATC-E electronics module, ATC-D and ATC-M gauge tubes, and various cable assemblies. Edwards offers a calibration service traceable to national standards for new or returned gauges and controllers.
Global Contacts: Contact information is provided for various regions including Europe, USA, Brazil, Israel, and Asia Pacific.
See more

Catalog excerpts

Active Thermocouple Gauges Datasheet-1

Active thermocouple gauges The Edwards Active Thermocouple (ATC-E) gauges mount directly on the thermocouple tube to form a compact, stand-alone vacuum transducer. The ATC-E electronics module drives both medium and low pressure gauge tubes. These gauges offer a cost effective measuring solution for higher pressures. Edwards Active Strain Gauges operate from standard 20 to 36 V dc power supplies with a 0 to 10 V dc signal output making them easy to interface with the users equipment. Alternatively they are directly compatible with Edwards Active Digital Controllers or TIC Instrument Controllers. Features and benefits • Drive electronics mount directly on the gauge tube ͳͳ Simplifies system design ͳͳ Saves valuable rack space • Low output impedance and integral Faraday shield ͳͳ Provides high level of noise immunity ͳͳ Permits long cable runs (up to 100 metres) • Wide range, regulated, internal power supply ͳͳ Runs from standard dc power supplies ͳͳ +20 to +36 V ͳͳ Tolerant to voltage fluctuations • Choice of medium and low pressure gauge tubes ͳͳ ATC-D covers from 50 to 5 x 10 -2 Torr ͳͳ ATC-M covers from 1 to 10 -3 Torr • Standard analogue output 0 to +10 V dc and gauge identifier ͳͳ Easy to interface with a computer or PLC ͳͳ Fault output indication • Adjustable set-point with vacuum status LED ͳͳ Use for process control and interlocking ͳͳ Includes a digital vacuum status signal ͳͳ Set-point level ready visually product datasheet Vacuum science... product solution.

 Open the catalog to page 1
Active Thermocouple Gauges Datasheet-2

Technical data Output characteristics ATC-E electronics module Power supply Power consumption Output signal Fault output Output impedance Minimum load Tube type selection Adjust set point visually via potentiometer Open collector transistor 2% to 85% full scale voltage Fixed hysteresis 12% full scale voltage Level setting ±2% full scale voltage External interface connector Electronic design Electromagnetic compatibility Flame retardant casing Ordering information ATC-D, ATC-M gauge tubes Pressure range ATC-D Maximum overpressure ATC-D Internal volume ATC-D/ATC-M Vacuum fitting Operating/storage...

 Open the catalog to page 2

All EDWARDS catalogs and technical brochures

  1. SPEEDIVALVE

    2  Pages

  2. GV

    12  Pages

  3. XDD1

    2  Pages

  4. PGC

    2  Pages

  5. 8200

    2  Pages

  6. IS 320FX

    2  Pages

  7. RGA

    8  Pages

  8. EH

    2  Pages

  9. RV

    8  Pages

  10. nXDS

    12  Pages

  11. XDS series

    4  Pages

  12. T-STATION 85

    2  Pages

  13. AIM

    2  Pages

  14. WRG

    2  Pages

  15. ASG2

    2  Pages

  16. ELD500

    8  Pages

  17. iXH Dry Pumps

    2  Pages

  18. RV Pumps

    8  Pages

  19. Small EM Pumps

    12  Pages

  20. GXS Dry Pumps

    20  Pages

  21. EDP Pumps

    4  Pages

  22. CXS Dry Pumps

    12  Pages

  23. ADC Datasheet

    4  Pages

  24. nEXT Brochure

    12  Pages

  25. CXS Dry Pump

    9  Pages

  26. EV Brochure

    6  Pages

  27. Spectra G

    4  Pages

  28. iGX Dry Pumps

    4  Pages

  29. T-Station 75

    2  Pages

  30. EXT75-255DX

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.