1. Catalogs
  2. EDWARDS
  3. Active ion gauge (AIGX)
video corpo

Active ion gauge (AIGX)

Active ion gauge (AIGX)

Active ion gauge (AIGX)

Product catalog summary
Product Overview: The document describes a compact active ion gauge (AIGX) with dual yttria-coated iridium filaments, offering a wide measuring range from 6.6 x 10-2 to 6.6 x 10-10 mbar (5 x 10-2 to 5 x 10-10 Torr) and a linear output of 1 Volt/decade. It features full 8-decade measurement capability and is available in two versions, each with three vacuum coupling variants.
Specifications: The gauge provides up to a thirty-fold reduction in charged particle process contamination compared to competitors. It includes automatic filament protection, constant gauge sensitivity across the measuring range, and continuous pressure measurement output during degas. The AIGX gauge incorporates integral electronics and a replaceable tube, with a degas facility to protect and extend filament life.
Features and Benefits: The design eliminates X-ray limit effects and includes a bi-colour LED for gauge status indication. It supports a wide input voltage range and allows easy electronics removal for bakeout up to 200°C. The 'S' versions offer seamless automatic emission current switching, diagnostic outputs, and a push-button adjustable set point.
Technical Data: The gauge operates with a power supply of +14.5 to +30.0 V dc, consuming 7W during normal operation and 14W during degas. It has a response time of approximately 100ms above 10-8 Torr and 1-2s below. The gauge's accuracy is typically +/- 15% of reading, with better accuracy available through optional calibration. It features manually selectable dual yttria-coated iridium filaments and a three-minute electron bombardment degas cycle.
Ordering Information: The document lists various product descriptions and order numbers for different gauge models and electronics modules. It also provides contact information for global sales offices.
See more

Catalog excerpts

Active ion gauge (AIGX)-1

Active ion gauge (AIGX) A compact active ion gauge with dual yttria coated iridium filaments, a wide measuring range from 6.6 x 10 -2 to 6.6 x 10 -10 mbar (5 x 10 -2 to 5 x 10 -10 Torr) and a 1 Volt/decade linear output. The AIGX gauge from Edwards incorporates all the benefits of the industry standard active gauging concept, with integral electronics and replaceable tube. The gauge has a degas facility and includes features to protect and extend the life of the filaments. The AIGX benefits from extremely low emissions of charged particles, which makes it an excellent choice for processes where background noise is undesirable. Features and benefits • Full 8-decade measurement capability, to 6.6 x 10 -10 mbar (5 x 10 -10 Torr) • Two versions available, each with three vacuum coupling variants: ͳͳ ‘D’ versions have a 9-pin ‘D’ connector and standard interface ͳͳ ‘S’ versions have enhanced functionality and are fully compatible with the range of Edwards controllers • Up to a thirty-fold reduction in charged particle process contamination compared to leading competitors • Automatic filament protection against switching on at atmosphere and running or degassing at high pressure • Gauge sensitivity remains constant over the whole measuring range, thus maintaining output accuracy at higher pressures • Continuous pressure measurement output during degas product datasheet • Innovative design eliminates the effects of X-ray limits • Bi-colour LED gives local indication of gauge status. • Wide input voltage range • Electronics very easily removable for bakeout at up to 200°C • ‘S’ versions provided with seamless automatic emission current switching, for prolonged filament life • ‘S’ versions provided with diagnostic outputs indicating ‘emission off’, ‘broken filament’ and ‘overpressure trip’ to help with troubleshooting • ‘S’ versions provided with a push-

 Open the catalog to page 1
Active ion gauge (AIGX)-2

Pressue range 6.6 x 10-2 to 6.6 x 10-10 mbar Power consumption Normal operation: 7W (max) Degas: 14W (max) Output signal Linear, 1 Volt/decade Response time 1.33 x 10-8 mbar (>10-8 Torr) ~100ms Tube details Typically +/- 15% of reading (better with optional calibration) Set point (open collector transistor) 1 on 'S' versions only Maximum voltage 30 V dc Temperature range Operating temperature 0° to +40°C External interface connectors 'S' versions 8-way FCC68/R145 socket Manually selectable dual yttria coated iridium Dimensions - shown in mm (inch) Degas Three minute electron...

 Open the catalog to page 2

All EDWARDS catalogs and technical brochures

  1. SPEEDIVALVE

    2  Pages

  2. GV

    12  Pages

  3. XDD1

    2  Pages

  4. PGC

    2  Pages

  5. 8200

    2  Pages

  6. IS 320FX

    2  Pages

  7. RGA

    8  Pages

  8. EH

    2  Pages

  9. RV

    8  Pages

  10. nXDS

    12  Pages

  11. XDS series

    4  Pages

  12. T-STATION 85

    2  Pages

  13. AIM

    2  Pages

  14. WRG

    2  Pages

  15. ASG2

    2  Pages

  16. ELD500

    8  Pages

  17. iXH Dry Pumps

    2  Pages

  18. RV Pumps

    8  Pages

  19. Small EM Pumps

    12  Pages

  20. GXS Dry Pumps

    20  Pages

  21. EDP Pumps

    4  Pages

  22. CXS Dry Pumps

    12  Pages

  23. ADC Datasheet

    4  Pages

  24. nEXT Brochure

    12  Pages

  25. CXS Dry Pump

    9  Pages

  26. EV Brochure

    6  Pages

  27. Spectra G

    4  Pages

  28. iGX Dry Pumps

    4  Pages

  29. T-Station 75

    2  Pages

  30. EXT75-255DX

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.