700 Series

700 Series

700 Series

Product catalog summary
Overview: The Edwards 700 Series smoke detectors are designed for commercial and industrial environments, featuring a photoelectric smoke detector with an interchangeable head and base. It includes a light-scattering optical sensor and a pulsed infrared LED light source housed in a protected sensing chamber.
Key Features:
  • Self-diagnostic capability that continually monitors operation.
  • Built-in drift compensation to adjust sensitivity over time.
  • Field-replaceable optical chamber for easy maintenance.
  • Low-profile design for aesthetic integration into ceilings.
  • Advanced nuisance alarm immunity.
  • Compliance with NFPA 72 field sensitivity testing without external meters.
  • Extensive two-wire compatibility listings.
  • Operating temperature range from 32°F to 120°F (0°C to 49°C).
Specifications:
  • Operating Voltage: 12/24V DC
  • Standby Current: 0.00007 A
  • Alarm Current: 0.06 A
  • Photoelectric Sensitivity: 2.85%, +0.37, -1.00%
  • Reset Time: 1 second
  • Drift Compensation Adjustment: 1%/ft. max.
  • Field Wire Size: 18-12 AWG
Models and Accessories:
  • 711U: Two-wire self-diagnostic smoke detector.
  • 721UT: Two-wire self-diagnostic smoke detector with heat detection.
  • 701U and 702U: Smoke detector bases with different terminal configurations.
  • 211-10PKG: Replacement optical chambers (package of 10).
Weights and Dimensions:
  • 711U and 721UT: 0.50 lb, 4.0 in. diameter, 1.75 in. height.
  • 701U and 702U: 0.25 lb, 6.0 in. diameter, 0.6 in. height.
See more

Catalog excerpts

700 Series-1

Conventional Fire Alarms Smoke Detectors 700 Series Edwards 700 Series smoke detectors are suitable for use in commercial and industrial environments. If the detector drifts out of its UL Listed sensitivity range or fails internal diagnostics, the alarm LED flashes once a second to indicate trouble. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. Features and Specifications • elf-diagnostic capability continually S monitors operation • Built-in drift compensation • Field-replaceable optical chamber • Low-profile design blends into the ceiling • Advanced nuisance alarm immunity • eets NFPA 72 field sensitivity testing without M the need for external meters • Extensive two-wire compatibility listings • White head and base • perating temperature range: 32°F to 120°F O (0°C to 49°C) The Edwards photoelectric smoke detector is an interchangeable head and base detector with a light-scattering optical sensor. A pulsed infrared LED light source and a high-speed photodiodesensing element are housed in an omni-directional sensing chamber protected by an insect screen. The chamber is not affected by ambient light. The detector features a field-replaceable optical chamber to simplify cleaning. The 721UT photoelectric detector includes integral fixed temperature heat detectors. Applying a magnet near the detector’s integral reed switch activates a self-diagnostic routine that provides visual indication of sensitivity level, or if service is required. Built-in drift compensation allows the detector to automatically adjust its sensitivity over time as it becomes dirty. Ordering Information Operating Cat. No. Voltage Current (Standby) Current (Alarm) Photoelectric Sensitivity Reset Time Field Wire Size Two-wire Self-Diagnostic Smoke Detector Two-wire Self-Diagnostic Smoke Detector with Heat Two-wire Self-Diagnostic Smoke Detector Bases Accessories Description Replacement optical Chambers (pkg. of 10)

 Open the catalog to page 1
700 Series-2

Conventional Fire Alarms Smoke Detectors 700 Series Weights and Dimensions Dimensions Approx. Shipping Weight (lb.) FIRE ALARMS

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.