Boxed - Gascard
2Pages

{{requestButtons}}

Catalog excerpts

Boxed - Gascard - 1

EDINBURGH SENSORS Infared gas sensors: Gascard Range BOXED GASCARD For CO2 KEY FEATURES • Modern electronics platform with the increased power and versatility of fast microprocessors • Wide operating voltage range (7 V - 30 V) • Options- True RS232 communications for control and data • On-board Barometric Pressure Correction in the range 800 mbar - 1150 mbar • Field Replaceable IR Source • Extensive Temperature compensation The Boxed Gascard is the latest development in the NG range of products from Edinburgh Sensors. It provides users with access to the Gascard NG range of CO2 detection products in a convenient and robust desktop unit. Requiring only a suitable power supply and sample gas, the Boxed Gascard provides fast and reliable CO2 concentration data over a wide range of barometric pressures and environmental temperatures. It brings the accuracy and reliability of the Gascard NG gas sensors to the convenience of a desktop instrument. The Boxed Gascard is suitable for CO2 monitoring in a diverse range of applications from anaerobic digestion monitoring to plant physiology, where the carbon dioxide concentration in air-like atmospheres needs to be measured from ppm to tens of percent concentration. The bit-switch controlled 4-20mA or 0-20mA output is ideally suited for interfacing with most data loggers. Alternatively, the optional RS232 interface and NG Logger software may be used to log the concentration information onto a PC (with a serial to USB converter) or suitable tablet computer. The new aluminium enclosure provides an elegant and robust solution to housing the Gascard NG. This also provides a versatile point sensor that may be used in many applications where a sensor is needed to remotely monitor carbon dioxide concentrations. The heart of the Boxed Gascard is the Gascard which uses a pseudo dual beam NDIR measurement system for increased stability and the reduction of long term drift with minimum optical complexity and no moving parts.

Open the catalog to page 1
Boxed - Gascard - 2

Infared gas sensors: Gascard Range TECHNICAL SPECIFICATIONS GAS MEASUREMENT RANGE Biogas (Special Calibration) ±2% of range ±<0.015% of range per mbar* Zero Stability ±2% of range (over 12 months) Response Time Operating Temperature Operating Pressure Power Requirements Warm-Up Time 1 minute (initial) 30 minutes (full specification) Measurements are unaffected by 0-95% relative humidity, non condensing Linear 4-20 mA, 0-20 mA (bit switch selectable) maximum load dependent on supply voltage The Boxed Gascard can also be supplied with an RS232 option and OEM external 24 V pump. *Not including...

Open the catalog to page 2

All EDINBURGH SENSORS catalogs and technical brochures

  1. GASCARD NG

    2 Pages

  2. IRGaskit

    2 Pages

  3. Gascard-NG

    2 Pages

  4. Guardian-NG

    2 Pages

  5. Gascheck

    2 Pages

  6. CHILLCARD NG

    2 Pages