TCC2 Electronics Module

TCC2 Electronics Module

TCC2 Electronics Module

Product catalog summary
Overview: The TCC2 Electronics Module is designed for time-resolved photon counting, utilizing Time-Correlated Single Photon Counting (TCSPC) and Multi-Channel Scaling (MCS) techniques. It supports up to three detector channels and allows for both forward and reverse modes of operation.
Specifications:
  • TCSPC Time Range: 2.5 ns to 50 ms
  • MCS Time Range: 5 ms to 200 s
  • Time Resolution: 305 fs/ch
  • Repetition Rates: Up to 100 MHz
  • Dimensions: 230 mm (W) x 445 mm (D) x 100 mm (H)
  • Power Requirements: 36 V (100 - 240 V power supply included)
Applications:
  • Time-Resolved Fluorescence (TCSPC)
  • Phosphorescence Lifetime (MCS)
  • Förster Resonance Energy Transfer (FRET)
  • Optical Tomography
  • Time of Flight / LIDAR
Technical Features:
  • The module integrates an ultra-fast flash Analogue-to-Digital converter with proprietary dead-time management, achieving acquisition frequencies up to 100 MHz.
  • Novel electronics eliminate the need for cable swapping or external delay selection.
  • Combines TCSPC and MCS data acquisition, covering a lifetime range from picoseconds to seconds.
Results and Examples:
  • Norharman in methanol showed three exponential lifetimes: neutral (2.3 ns), zwitterion (5.1 ns), and cation (18.0 ns).
  • Sample measurements include rare-earth doped glass and DASPI in ethanol, demonstrating the module's capability to measure a wide range of kinetics.
Customer Support: Available worldwide with contact information provided for both UK and US offices.
See more

Catalog excerpts

TCC2 Electronics Module-1

TCC2 Electronics Module Time-Resolved Photon Counting Features • TSCPC time range: 2.5 ns - 50 ms • MCS time range: 5 ms - 200 s • Time resolution from 305 fs/ch • Rep rates up to 100 MHz • Forward and reverse modes • Up to 3 detector channels Applications The TCC2 is a unique electronics module for the measurement of kinetics via TimeCorrelated Single Photon Counting (TCSPC) and Multi-Channel Scaling (MCS), and allows three sources and three detectors to be permanently connected. In TCSPC mode, kinetics from a few picoseconds can be measured using a high repetition rate source. TCSPC modules are generally available in two forms: with an Analogue-to-Digital Convertor which can have high temporal resolution, but may suffer from lower acquisition speed; or, with a Time-to-Digital Convertor (TDC) which has higher acuisition speed but at the expense of a reduced temporal resolution. The Edinburgh Instruments TCC2 works with an ultra-fast flash Analogue-to-Digital convertor and proprietary dead-time management. This demonstrates unrivalled temporal performance with acquisition frequencies up to 100 MHz. The module also incorporates novel electronics that eliminate the need for cable swapping or external delay selection. • Time-Resolved Fluorescence (TCSPC) • Phosphorescence Lifetime (MCS) • Förster Resonance Energy Transfer (FRET) • Optical Tomography • Time of Flight / LIDAR In MCS mode, kinetics from ~10 ns up to seconds can be measured with frequencies up to 1 MHz. The built-in TCSPC and MCS operations complement each other to allow the fast, simple measurement of kinetics over twelve orders of magnitude. The TCC2 is supplied with full data acquisition and lifetime analysis software. Time-Resolved Emission Spectroscopy (TRES) TRES is a powerful tool in fluorescence lifetime studies. This measurement example shows complex fluorescence decay kinetics for a single fluorophore; Norharman, dissolved in a protic solvent. The TCC2 data acquisition electronics work seamlessly with all of the comprehensive fluorescence data analysis software packages available from Edinburgh Instruments. Sample: Norharman in methanol (5×10-5M) Excitation Source: 280 nm pulsed LED (EPLED-280) Results: The resulting TRES map details the three different exponential lifetimes with overlapping emission bands of Norharman, highlighting the three different forms present; neutral = 2.3 ns, zwitterion = 5.1 ns,

 Open the catalog to page 1
TCC2 Electronics Module-2

Technical Specifications Combining TCSPC and MCS data acquisition in one electronics module enables a lifetime range that extends over twelve orders of magnitude, from a few picoseconds to seconds. Start & Stop Inputs Type Constant Fraction Delay Input Pulse Height Constant Fraction Constant Fraction Delay Plug-in Delay Frequency Divider Input Connectors The graph illustrates the range of kinetics that can be measured by both data acquisition techniques. Data Acquisition Modes of Operation Shifting Delay Number of Detector Channels Number of Synchronisation Channels Number of Reference Channels...

 Open the catalog to page 2

All Edinburgh Instruments catalogs and technical brochures

  1. MicroPL

    4  Pages

  2. VPLED

    2  Pages

  3. VPL

    2  Pages

  4. HPL

    2  Pages

  5. AGILE

    2  Pages

  6. RM5

    7  Pages

  7. EPLED Series

    2  Pages

  8. FLS1000

    24  Pages

  9. LifeSpec II

    4  Pages

  10. DS5

    4  Pages

  11. RMS1000

    16  Pages

  12. 295-FIR

    2  Pages

  13. 395-FIR

    2  Pages

  14. PL Series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.