EDINBURGH INSTRUMENTS TRANSIENT ABSORPTION SPECTROMETER

Open the catalog to page 1
LP980 Spectrometer Brochure - 2

2 LP980-K TRANSIENT ABSORPTION SPECTROMETER - KINETIC MODE Spectrometer system for measurements of transient absorption and laser-induced emission kinetics with the ability to automatically generate transient spectra. 10 LP980-SYSTEM OVERVIEW TRANSIENT ABSORPTION SPECTROMETER Configuration, layout, and specifications for the turn-key, modular and unrivalled spectrometer. 14 LP980-KS TRANSIENT ABSORPTION SPECTROMETER - KINETIC AND SPECTRAL MODE Spectrometer system for direct measurements of time-gated transient absorption and laser-induced emission spectra as well as kinetic measurements....

Open the catalog to page 2
LP980 Spectrometer Brochure - 3

TRANSIENT ABSORPTION / LASER FLASH PHOTOLYSIS TECHNICAL OVERVIEW Transient Absorption / Laser Flash Photolysis is a technique for studying the transient chemical and biological species generated by a short, intense light pulse from a nanosecond pulsed laser source (pump pulse). This intense light pulse creates short lived photoexcited intermediates such as excited states, radicals, and ions. These intermediates are generated in concentrations large enough for chemical and physical interaction to occur and for direct observation of the associated temporally changing absorption...

Open the catalog to page 3
LP980 Spectrometer Brochure - 4

OVERVIEW The LP980 Transient Absorption (TA) Spectrometer uses the same basic optical-electrical setup for operation in both the kinetic and the spectral mode, i.e. laser excitation source, probe source, sample compartment (including optics, attenuators, laser shutter, and probe shutter), monochromator / spectrograph, and control electronics. The difference between the two modes is the detector and the data acquisition electronics. In kinetic mode a PMT detector is used and the transients are acquired using a fast, high resolution oscilloscope. The LP980-K has been designed to meet the...

Open the catalog to page 4
LP980 Spectrometer Brochure - 5

SIGNAL DETECTION AND DATA ACQUISITION The LP980-K is supplied as standard with a red sensitive PMT which covers the spectral range from 200 nm 870 nm. The detector housing also accommodates the high voltage power supply and the voltage divider circuit. The PMT detector system is designed to achieve a high dynamic range with exceptional current linearity. This is an essential requirement in measuring small signals on a large signal background. The voltage divider and power supply are configured to support this high linearity current mode by operating in a five stage dynode configuration. The...

Open the catalog to page 5
LP980 Spectrometer Brochure - 6

Control Features • Wavelength / slit control • Filter wheel for second order light rejection • Grating selection • Pump laser flashlamp trigger • Pump laser Q-switch trigger • Probe source pulse current • Pump and probe shutters • Oscilloscope trigger • Oscilloscope time base • Oscilloscope voltage scale • Signal offset • Time shift / delay • Optional temperature controlled sample holder • Optional cryostat mounting • Stopflow synchronisation • Optional Energy Meters SOFTWARE The LP980-K spectrometer system is fully computer-controlled by means of the comprehensive L900 software package. A...

Open the catalog to page 6
LP980 Spectrometer Brochure - 7

MEASUREMENT EXAMPLES Transient Absorption and Photobleaching In TA, the presence of the transient species can cause the sample to have either increased or decreased levels of absorption relative to the absorption of the ground state species (positive ΔOD and negative ΔOD respectively). While an increased absorption is associated with triplettriplet or singlet-singlet transitions, a reduction in the measured optical density is associated with either ground state depletion or sample emission. Generally these effects can be separated spectrally, or by means of their lifetimes. In some special...

Open the catalog to page 7
LP980 Spectrometer Brochure - 8

Spectrally Dependent Transient Kinetics Time-resolved TA spectra can provide substantially more information than kinetic measurements alone. The measurement of benzophenone in cyclohexane shows two distinct absorption bands with maxima at 330 nm and 530 nm. The delay characteristics (measured with a PMT) show different decay kinetics in each band. Spectral measurements (measured with an ICCD camera) reveal that the longer wavelength band shifts towards the near-infrared spectral range with time. Sample: Benzophenone in cyclohexane Measurement Conditions: Top: Apump = 355 nm, Epump = 8 mJ,...

Open the catalog to page 8
LP980 Spectrometer Brochure - 9

TIME−RESOLVED ABSORPTION SPECTRA The LP980-K Spectrometer hardware is computercontrolled and enables the user to generate timeresolved absorption spectra in a two-fold process: firstly, a series of TA measurements over a pre-defined range of probe wavelengths is recorded, and, secondly, this data is sliced at desired time windows and delays from the laser pulse excitation. By automatically scanning through the spectral range the probe background level can change. The changing background level does not have an effect on the value of the optical density, but it has an effect on the noise of...

Open the catalog to page 9
LP980 Spectrometer Brochure - 10

SYSTEM The LP980-K is a system for the measurement of laser-induced TA and emission decay kinetics with the ability to automatically generate temporally resolved TA and emission spectra. Optional: Thin-film geometry, co-linear excitation, diffuse reflectance geometry, and fluorescence and phosphorescence lifetime measurements accessories are all available. Edinburgh Instruments Ltd. has a policy of continuous product development and reserve the right to amend specifications without prior notice (Aug 2018)

Open the catalog to page 10
LP980 Spectrometer Brochure - 11

LASER PUMP SOURCE In TA / Laser Flash Photolysis, transient species are generated using a short pulse, high peak power laser, known as the pump pulse. Suitable lasers include fixed wavelength lasers, particularly Nd:YAG lasers (fundamental wavelength 1064 nm) and their harmonics (at wavelengths 532 nm, 355 nm and 266 nm), or tuneable lasers, particularly optical parametric oscillators (OPOs). Other lasers sometimes used include nitrogen, excimer lasers and dye lasers. The LP980 has been designed with the ultimate flexibility in mind. It can be supplied either as a turn-key, fully tested and...

Open the catalog to page 11

All Edinburgh Instruments catalogs and technical brochures

  1. MicroPL

    4 Pages

  2. VPLED

    2 Pages

  3. VPL

    2 Pages

  4. HPL

    2 Pages

  5. AGILE

    2 Pages

  6. RM5

    7 Pages

  7. EPLED Series

    2 Pages

  8. FLS1000

    24 Pages

  9. LifeSpec II

    4 Pages

  10. DS5

    4 Pages

  11. RMS1000

    16 Pages

  12. 295-FIR

    2 Pages

  13. 395-FIR

    2 Pages

  14. PL Series

    4 Pages