Catalog excerpts
DIGITAL DISPLAY for Industry Applications Serie REX-D Key-Features: Content: Technical Data Technical Drawing Electrical Connection Programming Control Modes Order Code & Accessories - REX-D-X345: only display - REX-D-X347: display with two presets and switching out puts - REX-D-X348: Display with serial RS232 and RS485 Interface - High speed position and event counter (100 kHz) - Tachometer and frequency meter - Timer, Stop watch - Additional functions: linearisation, brightness control, digital filter, etc.
Open the catalog to page 1TECHNICAL DATA REX Display Panel cut out 6 digits, 15 mm LEDs, high efficiency orange [mm] Inputs Input currents 91 x 44 3 (PNP / NPN / Namur), A/B = Impulse, C = Reset Input level HTL (Standard) Input level TTL (Option -TTL) CMOS levels, Low: 0...0.8, High: 3.6...5 Input frequency max. Display update rate Accuracy frequency measurement Supply voltage Power Consumption Supply voltage 100 for all counter modes/ 25 for all other operating modes / Reset input C: 1 (Min. pulse duration 500 μs) approx. 7 (at tachometer operation: 330) 100 ppm ±1 Digit Consumption (without sensors) Aux. voltage...
Open the catalog to page 2ELECTRICAL CONNECTION REX-D-X345 Display unit only Special versions with TTL inputs (option) provide a +5 V aux. output on terminal 7, instead of +24 V. ELECTRICAL CONNECTION REX-D-X347 Display unit with 2 presets and transistor outputs Special versions with TTL inputs (option) provide a +5 V aux. output on terminal 7, instead of +24 V. The outputs provide programmable switching characteristics and are potential-free. Please connect terminal 8 (COM+) to the positive potential of the voltage you like to switch (range 5V...30V). You must not exceed the maximum output current of 150 mA. Where...
Open the catalog to page 3ELECTRICAL CONNECTION REX-D-X348 Display unit with serial interface Special versions with TTL inputs (option) provide a +5 V aux. output on terminal 7, instead of +24 V. Ex factory the unit is set to RS 232 communication. This setting can be changed to RS 485 (2-wire) by means of an internal DIL switch. To access the DIL switch, please remove the screw terminal connectors and the backplane. Then pull the print to the rear to remove the PCB from the housing. Removal of the back plane - Never set DIL switch positions 1 and 2 or DIL switch positions 3 and 4 to ON at the same time! - After...
Open the catalog to page 4PROGRAMMIERUNG The programming is described in detail in the included manual. For setup and other operations the unit uses three front keys which subsequently will be denominated as follows: The functions of the keys are depending on the actual operating state of the unit. The following three operating states apply: - Normal display state - Setup state a) Basic setup b) Operational parameter setup - Teach operation Operator menu The menu provides one section with „Basic Parameters“ and another section with „Operational Parameters“. On the display you will only find those parameters which...
Open the catalog to page 5CONTROL MODES Mode „RPM“ Mode „ Time“ Mode „ Timer“ Mode „Count“ Mode „Speed“ Display Format Base (Resolution) Counter Mode Display Value Scaling Factor Display Value Decimal Point Display Value Auto Reset Decimal Point Wait Time Wait Time Average Filter Average Filter Reset/Set Decimal Point Wait Time Display Format Base (Resolution) Counter Mode Display Value Scaling Factor Display Value Decimal Value Auto Reset Decimal Point Wait Time Wait Time Decimal Point Average Filter Display Format Latch Function Reset/Set Decimal Point Wait Time Display Value Decimal Point Auto Reset Wait Time...
Open the catalog to page 6ORDER CODES
Open the catalog to page 7Subject to change without prior notice. eddylab GmbH Tel. +49 (0)8024 46772-0 E-mail info@eddylab.de Ludwig-Ganghofer-Str. 40 Fax +49 (0)8024 46772-100 Internet www.eddylab.de
Open the catalog to page 8All Eddylab GmbH catalogs and technical brochures
-
Inductive sensor SM
8 Pages
-
Product Overview
16 Pages
-
eddycurrent probes CT series
7 Pages
-
TX Series - EDDY CURRENT PROBES
20 Pages
-
TX LVDT Digital Controller
8 Pages
-
Laser sensors AXIS SERIES
11 Pages
-
LH70/LH71 - Magnescale ®
4 Pages
-
SL inductive transducer
8 Pages
-
AX Series
8 Pages
-
MAGNESCALE
11 Pages
-
SM-HYD
8 Pages
-
DIGITAL DISPLAY
6 Pages
-
SM-F14 SERIES
8 Pages
-
SM-F18 SERIES
8 Pages
-
AX-turbo Eddy Current Probe
6 Pages
-
SM-F18
8 Pages
-
Inductive sensor SL
8 Pages
-
Inductive Sensor SLT
8 Pages
-
DT series DMAGNESCALE
13 Pages
-
PL101 - Magnescale ®
8 Pages
-
MB-LK, MB-LKM ®
6 Pages
-
PL81, PL82 - Magnescale ®
6 Pages
-
SR-series Magnescale ®
16 Pages
-
REX-Series
8 Pages
-
PMX-24
4 Pages
-
PAXI
6 Pages
-
PAX P, DP
6 Pages
-
LG20 - Magnescale ®
4 Pages
-
SJ-700A - Magnescale ®
4 Pages
-
GB-ER - Magnescale ®
6 Pages
-
DK800S Series - Magnescale ®
8 Pages