PAXI

PAXI

PAXI

Product catalog summary
Key Features:
  • 6-digit display with 14 mm high red LEDs and annunciators.
  • Two independent inputs supporting TTL, NPN, and PNP sensors.
  • Maximum measurement frequency of 34 kHz.
  • Three programmable user inputs with IP65 protection class.
  • Operating temperature range from 0 to 50°C.
  • Easy programming via direct input or PC.
  • Supports plug-in output cards including analog, USB, relay, transistor, RS232, and Profibus.
  • Features summation and min/max value display with 10-point scaling for non-linear processes.
Technical Specifications:
  • Display: 6 digits, 14 mm high, red LEDs with a panel cut-out of 92 mm x 45 mm.
  • Input signals: Incremental sensors with TTL, NPN, and PNP settings via DIP switches.
  • Output signals: Relay, transistor, and analog outputs via plug-in cards.
  • Serial interfaces: USB, RS485, RS232, and Profibus via plug-in cards.
  • Supply voltage: PAXI003B (11-36 VDC/24 VAC), PAXI002B (85-250 VAC).
  • Sensor supply: 12 VDC, regulated, max 100 mA.
  • Measurement rate: Max 34 kHz with tachometer accuracy of ±0.01%.
  • Protection class: IP65 (face only), humidity max 85% without condensation.
  • Housing dimensions: 97 mm x 50 mm x 104 mm, weight 300 g without plug-in cards.
  • Electromagnetic compatibility: Conforms to CE, EN 50081-2, EN50082-2.
Plug-in Cards:
  • Analog Output Card: Types include 0 to 20 mA, 4 to 20 mA, or 0 to 10 VDC with isolation and accuracy specifications.
  • Interface Cards: RS232, RS485, DeviceNet, and Profibus with isolation specifications.
  • Setpoint Alarm Output Cards: Options for quad sourcing/sinking open collector and dual/quad relay cards.
  • USB Card: Suitable for slow measurements with a virtual COM port.
Programming:
  • Direct programming via display keys with Quick and Full Programming Modes.
  • Software programming via RS232 or RS485 cards using Windows-based software.
  • ProLOG software for data visualization and storage on Windows PCs.
Order Codes and Accessories:
  • Various plug-in cards and housings available, including aluminum housing with IP65 protection.
  • Voltage supply options: PAXI002B (85 to 250 VAC) and PAXI003B (11 to 36 VDC/24 VAC).
See more

Catalog excerpts

PAXI-1

Content: Technical Data Technical Drawing Electrical Connection Plug-in Cards Programming & Software Order Code & Accessories Serie PAX I Key-Features: - 6 digits, 14 mm high LEDs, annunciators - 2 independent inputs - Input signals TTL, NPN- and PNP-Sensors - Measurement frequency max. 34 kHz - 3 programmable user inputs - Protection class IP65 - Working temperature 0 to 50 °C, - Easy programming directly, or via PC ■2 - Plug-in output-cards: analog, USB, ■3 Relay (thresholds), Transistor, RS232, Profibus .4 - Summation, min-/max value display .5 - 10 point scaling for non-linear processes

 Open the catalog to page 1
PAXI-2

TECHNICAL DATA Display 6 digits, 14 mm high, red LEDs Panel cut-out A, B, C (counter), SP1, SP2, SP3, SP4 (the respective output is active) Programmable user inputs 3, logic state: jumper selectable for sink/source logic PNP: active Vin >2.4 VDC, inactive Vin <0.9 VDC, NPN: active Vin <0.9 VDC, inactive Vin >2.4 VDC Input signal incremental sensors with TTL signal, NPN and PNP sensors (settings by DIP switches) Output signal (via plug-in cards) Relay output, transistor output, analog output Serial Interfaces (via plug-in cards) USB port (programmable), RS485, RS232, Profibus Prescaler Output...

 Open the catalog to page 2
PAXI-3

- black powder coating - internal grounding terminal. - protection class: IP65 - dimensions: (W x H x D) 168 mm x 83 mm x 220 mm - delivery: housing, mounting material - without cable passages (must be drilled individually) - The housing is suited for all displays with front dimensions 96 x 48 mm - self assembly - dimensions: (W x H x D) 114 mm x 62 mm x 176 mm - delivery: housing, mounting material

 Open the catalog to page 3
PAXI-4

The display can be fitted with up to three optional plug-in cards. The details for each plug-in card can be reviewed in the specification section below. Only one card from each function type can be installed at one time. The plug-in cards can be installed initially or at a later date. Analog Output Card (retransmitted linear DC output): PAXCDL10 - Types: 0 to 20 mA, 4 to 20 mA, or 0 to 10 VDC. - Isolation to sensor + user input commons: 500 Vrms for 1 min., working range 50V, not isolated from all other commons. - Accuracy: 0.17 % of FS (10 to 28 degree Celsius), 0.4% (0 to 50 degree Celsius) -...

 Open the catalog to page 4
PAXI-5

PROGRAMMING Directly by the displays keys The meter normally operates in the Display Mode. No parameters can be programmed in this mode. The Programming Mode is entered by pressing the PAR key. If it is not accessible then it is locked by either a security code, or a hardware lock. Two types of programming modes are available. Quick Programming Mode permits only certain parameters to be viewed and/or modified. All meter functions continue to operate except the front panel keys change to Programming Mode Operations. Quick Programming Mode is configured in Module 3. Full Programming Mode permits...

 Open the catalog to page 5
PAXI-6

Plug-in cards Software PAXCDC20 Serial communication card RS232, terminal ProLOG on request PAXCDS10 Dual relay, Form-C, normally open & closed PAXCDS20 Quad relay, Form-A, normally open only PAXCDS30 Quad sinking NPN open collector PAXCDS40 Quad sourcing PNP open collector PAXCDC2C Serial communication card RS232, 9 pole SUB-D connector Miscellaneous Housings PAXLBK10 Units label kit GEH0IP65 Aluminium housing, IP65 Einstellung Pre-adjustment according to customer demands TG9648 Table housing Subject to change without prior notice. eddylab GmbH Tel....

 Open the catalog to page 6