T14/T20/T40 EDDY CURRENT PROBES ■ contactless distance measurement due to non-contact measuring principle for measuring ranges up to 45 mm ■ highest precision in difficult industrial environments ■ resistant to contamination, high temperatures and pressure ■ high temperature stability ■ robust
Open the catalog to page 12 TECHNICAL DATA SENSORS I T14/T20/T40 measurement range extended [mm]* housing size offset gap (blind range) resolution reg. corner frequency [% FS]** * Linearity and resolution are not valid for extended measurement ranges ** 98.5% confidence interval (confidence limit), middle of range as % of range. Resolution dependent on the distance. Further information about the eddy current measuring principle, the eddy current software eddyMOTION, technical data, drawings and pin assignment of the TX electronics as well as further accessories can be found in the eddylab data sheet for the eddy current...
Open the catalog to page 2TECHNICAL DRAWINGS − SENSORS Oberfläche / surface Gewicht / weight Werkstoff / material Name / title Datum / date Name / name Maßstab / scale Allgemeintoleranz / general tolerances Zeichnungsnr. / number Verwendungsbereich / type Blatt / page Maßstab / scale Oberfläche / surface Gewicht / weight Name / title Datum / date Name / name Allgemeintoleranz / general tolerances Zeichnungsnr. / number Verwendungsbereich / type Allgemeintoleranz / general tolerances Maßstab / scale Gewicht / weight Werkstoff / material Name / title Blatt / page
Open the catalog to page 3The sensors are supplied with a multipole female LEMO connector as standard. For connection to the TX-Driver a cable with BNC connector is required. Optionally the cable are equipped with a SMB connector. The SMB connection is performed as BNC/SMB adaptor. Please note: The connector housing has an outer diameter of 6.5 mm. This facilitates the installation in particular with narrow conditions. If the cable is durably affixed, it might be desirable only to remove the probe from the entire cable. It is recommended to avoid unnecessary connections within the cable as it increases the probability...
Open the catalog to page 4The processor based design admits linearities less than 0.1 % - which is an exceptional feature for this sensor technology. Remarkable performance allows highly dynamic measurements with 124 kSa/s. The TX-Driver is available as single- or dual-channel device. As standard, the device provides a USB and a CAN-bus Interface. The power supply is a galvanically isolated wide input from 10.5..36 (27) VDC. All available sensor heads can be connected with the basic module TX. ■ Probe and analogue output: Isolated output and high-speed signals via BNC connector. Selectable output signals 10 V, 5 V, ±...
Open the catalog to page 5ELECTRICAL INSTALLATION PROBE INSTALLATION OBJECT SIZE AND THE EDDY CURRENT MEASUREMENT FIELD Choose a dry location, preferably with a stable temperature for the electrical installation (TX-Driver) such as electrical cabinets, terminal boxes, housing, etc. Connect the supply line, probe lines and output lines. Please ensure that all supply and signal lines are laid separately from energy-carrying lines such as supply and discharge lines from converters and drives, lines from ovens and synchronised appliances or generator lines, etc., in order to avoid malfunctions in the signal behaviour. Please...
Open the catalog to page 6ORDER CODE SENSOR probe type a according to technical drawings, (e. g., T14, T20, T40) CONNECTION CABLE CONNECTION CABLE STANDARD LEMO.0T-KOAX-3M LEMO.0T-KOAX-6M LEMO.0T-KOAX-9M LEMO.0T-KOAX-12M LEMO.0T-KOAX-15M OPTIONAL CONNECTION CABLE + BNC/SMB-ADAPTOR LEMO.0T-KOAX-3M-SMB LEMO.0T-KOAX-6M-SMB LEMO.0T-KOAX-9M-SMB
Open the catalog to page 7eddylab GmbH Ludwig-Ganghofer-Str. 40, 83624 Otterfing Internet: www.eddylab.de
Open the catalog to page 88 Pages
8 Pages
7 Pages
8 Pages
8 Pages
8 Pages
16 Pages
7 Pages
20 Pages
8 Pages
11 Pages
4 Pages
8 Pages
11 Pages
8 Pages
6 Pages
6 Pages
13 Pages
8 Pages
6 Pages
6 Pages
16 Pages
8 Pages
4 Pages
6 Pages
6 Pages
4 Pages
4 Pages
6 Pages
8 Pages