video corpo

DT series DMAGNESCALE
13Pages

{{requestButtons}}

Catalog excerpts

DT series DMAGNESCALE - 1

MAGNESCALEdigital gauge Magnescale - Measurement ranges: 12,32 mm (DT Series) - Measurement ranges: 12, 30, 60 mm (U Series) - Resolution up to 1 pm - Linearity up to 2 pm - Output signal A/B, TTL-Linedriver, EIA-422 with MT14 - USB (2.0 FS) interface with MT30 - free evaluation soft ware for download - Protection class up to IP64 - Spring loaded and pneumatic versions - Resistant against water and oil - Life cycle up to 30 million strokes

Open the catalog to page 1
DT series DMAGNESCALE - 2

DIGITAL GAUGES DT12, DT512 Model Measurement range Resolution depending on the unit to be connected: 1 channel displays (e.g. LT10A-105): 100 / 2 channel displays (e.g. LT11A-201): 80 Spring push-out Reference point Working temperature Storage temperature Measuring force Protection class * Life cycle Steel ball tip ø3 mm, screw M2,5 Cable length compatible display *Excluding the interpolation box and connector DT12N, DT512N

Open the catalog to page 2
DT series DMAGNESCALE - 3

DIGITAL GAUGE DT32 Model Measurement range Linearity (20°C) Displacement speed max. depending on the unit to be connected: 1 channel displays (e.g. LT10A-105): 100 / 2 channel displays (e.g. LT10A-205): 80 spring push-out Pneumatic push Reference point spring push-out Pneumatic push Working temperature Storage temperature Measuring force Protection class * Weight *Excluding the interpolation box and connector Steel ball tip ø3 mm, screw M2,5 compatible display Feeler Cable length

Open the catalog to page 3
DT series DMAGNESCALE - 4

INSTALLATION INSTRUCTION Mounting method using mounting hole Mounting method using holder Mounting holder dimensions and tolerance

Open the catalog to page 4
DT series DMAGNESCALE - 5

INTERPOLATOR MT14 Using the interpolator unit MT14 the digital gauges of the series DT12, DT32 and DT512 can directly be connected to PLCs etc. MT14 Resolution Output signal Voltage-differential line driver output (compliant with EIA-422) Working temperature Storage temperature 1.2 (when output load of 120 Ω is connected) Cable color 0 V and the shield (FG) are connected with a capacitor. Phase difference for phase A/B output in depending on the displacement speed v [m/min] MT14-01 * An alarm is output at a traveling velocity of 100 to 115 m/min. The sampling frequency of the

Open the catalog to page 5
DT series DMAGNESCALE - 6

Using the interpolator unit MT30 the digital gauges DT12, DT32 and DT512 can be connected to the USB port of a PC. With the free basic software tool the measuring values ca be read out and saved in an excel or csv file. • Up to 8 gauges can be connected • Easy to operate and setup • Comparator function • Calibration (Reset) function • Scaling function • Available in various languages • Compatible with Windows 7/8/10 (XP possible)

Open the catalog to page 6
DT series DMAGNESCALE - 7

DIGITAL GAUGE U Model MR when using air release DZ173 Display Displacement speed maximal LCD Display, 6 digits, minus display [m/s] Reference point Working temperature Storage temperature 6 VDC ±10 % (with DC IN jack) 6 to 9 VDC ±10 % (with data connector used) Supply * Consumption Feeler Weight Carbide ball tip, Mounting screw M2.5 [g] appox. 230 Instruction Manual, lift lever, and dedicated spanner * Power supply unit AC-K02 please order separately

Open the catalog to page 7
DT series DMAGNESCALE - 8

ACCESSORIES DT SERIES Feeler Set DZ5100: 1. Off-center contact point: ø1,0 mm steel ball 2. Flat carbide contact point ø 6,5 mm 3. Plastic ball contact point ø3,0 mm, nylon ball 4. Pin contact point ø1,5 mm Tastkopf-01: steel (standard) Taskopf-01-HM: cemented carbide Tastkopf-01-R: ruby Tastkopf-01-K: ceramics Tastkopf-02: steel Tastkopf-02-HM: cemented carbide * Material of the feeler balls: steel: for standard applications ruby: much harder and wear resistant than steel, non-conductive, for all applications except for measuring on aluminium and cast iron ceramics: comparable to ruby,...

Open the catalog to page 8
DT series DMAGNESCALE - 9

Measuring range - The supply air should be cleaned by using a filter. - Without the airlifter a spring inside of the sensor pushes the rod outwards. - With the airlifter installed the rod will be pulled inside by a stronger spring inside of the airlifter. - When air is supplied the rod will be pushed out again and the measurement can begin. - The rod retraction speed can be adjusted by the speed controller mounted on the DZ176. Lift lever DZ161 (included in delivery)

Open the catalog to page 9
DT series DMAGNESCALE - 10

DISPLAYS LT10A Suitable gauges Standard (without interface) Working temperature Storage temperature Key Features • Resolution : selectable • Suitable for panel mounting • Direct interfacing from display unit to PLC or computer • Current values, maximum, minimum, peak-to-peak values and GO/NO GO evaluation included as standard functions. • ADD/SUB function (2-channel model) • Full lineup for various applications Connection cable DZ252 for LT Display with RS232 interface for connection to a PC, RS232 card, etc. DZ252 cable for RS232C (for LT and U series), round 8-pin male <─> D-sub 9-pin...

Open the catalog to page 10
DT series DMAGNESCALE - 11

ORDER CODE DIGITAL GAUGE N P ORDER CODE DISPLAY ORDER CODE INTERPOLATOR MT30- Resolution 1 ^m Resolution 5 ^m Resolution 10 ^m ACCESSORIES Accessories USB-extension cable CE38-01 1 m, USB

Open the catalog to page 11
DT series DMAGNESCALE - 13

Subject to change without prior notice. eddylab GmbH Ludwig-Ganghofer-Str. 40 83624 Otterfing E-mail info@eddylab.de Internet www.eddylab.de

Open the catalog to page 13

All Eddylab GmbH catalogs and technical brochures

  1. AX Series

    8 Pages

  2. MAGNESCALE

    11 Pages

  3. SM-HYD

    8 Pages

  4. Serie REX-D

    8 Pages

  5. SM-F18

    8 Pages

  6. REX-Series

    8 Pages

  7. PMX-24

    4 Pages

  8. PAXI

    6 Pages

  9. PAX P, DP

    6 Pages