Catalog excerpts
CM SERIES | EDDY CURRENT SENSOR Ultra-compact sensors for monitoring dynamic machine components under high pressure and temperature conditions. ■ contactless distance measuring under high pressure and temperature conditions ■ shielded sensor for universal usability on limted space ■ ceramic housing ensures high resistance even under high temperature ■ ultra compact sensors for a best application compatibility ■ monitoring of combustion engines
Open the catalog to page 1The CM Series are eddy current sensors, excellent for use in harsh industrial environments under high pressure and temperature conditions. The ceramic housing can be used as the pressurised component, there is no extra housing needed. All CM sensors are shielded. The combination of shielded coil and ceramic housing guarentees an universal use in limited space of machine parts. Measuring of lubrication gap of crankshafts is a typical application for the CM series. THE BASIC PRINCIPLE The principle of measurement bases on a DSP-driven oscillating circuit made up of the probe (inductance) and...
Open the catalog to page 2CM SERIES I TECHNICAL DATA 3 temperature range sensor temperature coefficient sensor sensor cable PTFE-COAX cable length min. bend radius static/dynamic temperature range cable connection protection class sensor vibration shock check resistance [Q] housing material -60...185°C dependent on distance 01,8 mm 3 m / customised length on request 6/18 mm -55...+200 °C BNC connector / optional SMB connector IP68 20 g, DIN EN 60068-2-6 100 g / 6 ms, DIN EN 60068-2-27 n.a. sensor head ceramics * further measuring ranges on request ** 98,5% 98.5% confidence interval (confidence limit), middle of...
Open the catalog to page 34 TECHNICAL DRAWINGS | CM SERIES TECHNICAL DRAWINGS − SENSORS
Open the catalog to page 4INSTALLATION ■ ELECTRICAL INSTALLATION Choose a dry location, preferably with a stable temperature for the electrical installation (TX-Driver) such as electrical cabinets,terminal boxes, housing, etc. Connect the supply line, probe lines and output lines. Please ensure that all supply and signal lines are laid separately from energy-carrying lines such as supply and discharge lines from converters and drives, lines from ovens and synchronised appliances or generator lines, etc., in order to avoid malfunctions in the signal behaviour. Please use shielded supply lines only and apply the...
Open the catalog to page 5eddylab GmbH Ludwig-Ganghofer-Str. 40, 83624 Otterfing E-mail: info@eddylab.de Internet: www.eddylab.de
Open the catalog to page 6All Eddylab GmbH catalogs and technical brochures
-
Inductive sensor SM
8 Pages
-
Product Overview
16 Pages
-
eddycurrent probes CT series
7 Pages
-
TX Series - EDDY CURRENT PROBES
20 Pages
-
TX LVDT Digital Controller
8 Pages
-
Laser sensors AXIS SERIES
11 Pages
-
LH70/LH71 - Magnescale ®
4 Pages
-
SL inductive transducer
8 Pages
-
AX Series
8 Pages
-
MAGNESCALE
11 Pages
-
SM-HYD
8 Pages
-
Serie REX-D
8 Pages
-
DIGITAL DISPLAY
6 Pages
-
SM-F14 SERIES
8 Pages
-
SM-F18 SERIES
8 Pages
-
AX-turbo Eddy Current Probe
6 Pages
-
SM-F18
8 Pages
-
Inductive sensor SL
8 Pages
-
Inductive Sensor SLT
8 Pages
-
DT series DMAGNESCALE
13 Pages
-
PL101 - Magnescale ®
8 Pages
-
MB-LK, MB-LKM ®
6 Pages
-
PL81, PL82 - Magnescale ®
6 Pages
-
SR-series Magnescale ®
16 Pages
-
REX-Series
8 Pages
-
PMX-24
4 Pages
-
PAXI
6 Pages
-
PAX P, DP
6 Pages
-
LG20 - Magnescale ®
4 Pages
-
SJ-700A - Magnescale ®
4 Pages
-
GB-ER - Magnescale ®
6 Pages
-
DK800S Series - Magnescale ®
8 Pages