EC9850T TRACE SULFUR DIOXIDE ANALYSER The Ecotech Model EC9850T Trace Sulfur Dioxide (SO2) analyser incorporates UV pulsed fluorescence spectrometry with microprocessor control for accurate and reliable measurement of sub-ambient levels of SO2. The EC9850T can measure levels of SO2 to a sensitivity of 200 ppt in the range of 0-2000 ppb. The SO2 concentration is automatically corrected for gas temperature and pressure changes and can be displayed in units of ppb, ppm, µg/m3 or mg/m3. Excitation (UV radiation) is measured by a reference detector and emission (fluorescence radiation) from the sample is measured by a photomultiplier tube (PMT). APPROVALS • EC9850T is U.S. EPA approved (Automated Equivalent Method EQSA-0193-092). FEATURES • Specially selected high output UV lamp operating at 214 nm. • Extremely low sensitivity to NO interferences. • Scrubbed sample air is used for background zero to minimise discrepancies between air quality of the sample and background air. • Auto-zero routine allows the analyser to periodically check and correct for cell contamination. • Kalman digital filter continuously provides the best compromise between response time and noise reduction. • Internal data logging uses Flash ROM to store up to 175 days of 5 minute averaged data.
Open the catalog to page 1SPECIFICATIONS Display: Auto ranging 0-2000 ppb. Data display: Graphic LCD display, auto ranging 0-2000 ppb full scale, with unit selection mg/m3, µg/m3, ppm, ppb, ppt. Resolution: User selectable (0-5 decimal points displayed). Analogue out: 0 - full scale from 0 - 2000 ppb. Selectable offset of 0 %, 5 % or 10 % offset. Filter types: No filter, Kalman, 10, 30, 60, 90, 300 second. Noise (At zero): 100 ppt RMS with Kalman or 300 sec filter active. Lower detectable limit: 200 ppt with Kalman or 300sec filter active. Precision: 500 ppt or 0.5 % of reading, whichever is greater. Zero drift:...
Open the catalog to page 2All Ecotech catalogs and technical brochures
-
Operations & Maintenance
12 Pages
-
Environmental Monitoring
16 Pages
-
ORION
6 Pages
-
VOC1000
1 Pages
-
FUSION
6 Pages
-
DUO
6 Pages
-
CUBE
6 Pages
-
NO2 Analyser
8 Pages
-
Serinus 51 SO2/H2S Analyser
2 Pages
-
BLAST MONITORING Solutions
4 Pages
-
Serinus Cal
8 Pages
-
SPECTRONUS analyzer
12 Pages
-
ECOTECH Company Profile
16 Pages
-
WINAQMS
4 Pages
-
PROTINUS 1000
2 Pages
-
NH3 Analyser Serinus 44
2 Pages
-
EC9843 NOy analyzer
2 Pages
-
EC9820T CO2 trace analyzer
2 Pages
-
SO2 Analyser EC9850
2 Pages
-
SO2 Analyser Serinus 50
2 Pages
-
NOx EC9841AS
2 Pages
-
NOx EC9841
2 Pages
-
CO Analyser EC9832
2 Pages
-
CO Analyser Serinus 30H
2 Pages
-
CO Analyser Serinus 30
2 Pages
-
Serinus 10
2 Pages
-
SERINUS Gas Analyser Series
4 Pages
-
GasCal 1100 gas calibrator
2 Pages
-
WinAQMS Data Logger
4 Pages
-
Serinus 10 Ozone Analyzer
2 Pages
-
HiVol 3000 PUF Sampler
2 Pages
-
HiVol 3000 XAD Sampler
2 Pages
-
Converters
2 Pages
Archived catalogs
-
Environmental Monitoring 2019
16 Pages
-
Corporate Profile
6 Pages
-
EC9830T CO trace analyzer
2 Pages
-
EC9811 Ozone photometer
2 Pages
-
EC9841T NOx trace analyzer
2 Pages