Catalog excerpts
ACOEM Group Direct vs Indirect NO2 Measurement Do it directly with the new Serinus® 60 gas analyser
Open the catalog to page 1Serinus® 60 Because the world needs direct NO2 measurement like never before ECOTECH presents the latest addition to the renowned Serinus® range: The Serinus® 60 NO2 analyser with CAPS technology. Cavity Attenuated Phase Shift (CAPS) allows direct measurement of nitrogen dioxide (NO2), rather than an indirect calculation from a chemiluminescence analyser. Using a modulated blue LED light source, the detector measures the phase shift attributable to the level of NO2 in the measurement cell over an average path length of several kilometres. No converter, no high vacuum, no ozone and no...
Open the catalog to page 2Nitrogen dioxide is in the forefront of concerns over air pollution in cities worldwide. Authorities have been forced to take drastic measures, such as odd-even number plate days, green taxes, car-scrapping and ride-sharing programmes in an attempt to mitigate the problem. But, as urban populations, industry, vehicle ownership and transportation increase, the underlying issue is getting worse. For environmental protection agencies NO₂ has long been ‘on the radar’ as a criteria gas. Until the advent of the advanced and more affordable CAPS technology, levels were derived from indirect...
Open the catalog to page 3Serinus® 60 It’s a game changer For years now, the Serinus® range has been recognised internationally for precision and usability. The new Serinus® 60 is no different. It has been designed from the outset with the user in mind: intuitive to use, simple to configure and offering in-the-field accuracy and reliability. APPLICATIONS FOR PRECISE, DIRECT & RAPID MEASUREMENTS Traffic emissions monitoring: roadside, tunnels Ambient air quality monitoring Indoor air quality monitoring Mobile and fixed monitoring stations Industrial fence-line monitoring These qualities count, when the risks from NO2...
Open the catalog to page 45 Micron Sample Filter Background Scrubber Disposable Absorption Unit Calibration Valve Manifold 0.01 Micron Sample Disposable Filtration Unit Attenuated Wave Form Measured Modulated Square Wave Form Emitted Blue LED Light Source 450 nm
Open the catalog to page 5Serinus® 60 comes with the backing of ECOTECH A G LO BA L L EA D E R I N E NV I R O N ME N TAL M ON I TORI N G SI NC E T H E 1 970 S Today, ECOTECH is a trusted partner in the protection of workforces, communities and the environment in over 80 countries. We operate and maintain one of the largest networks of monitoring systems in the world. The quality of our products and solutions are second to none, and we’re globally recognised for our expertise in technical support. It all stems from the problem-solving mindset that’s been part of our DNA since day one, and still drives us today. It...
Open the catalog to page 6Serinus® 60 Options High Pressure Span Calibration Valve: When a dilution system is not an option calibrate direct from a gas cylinder. I Metric Fittings: Do you have issues sourcing imperial tubing? Select our metric fittings option to make pneumatic connection trouble free. Internal Pump: Perfect for compact shelters and remote locations. High Pressure Zero Calibration Valve: Gives you the flexibility to connect your zero gas cylinder directly to the analyser for a simple check. Network Port: Connect your analyser to the internet to have direct remote access from anywhere in the world. I...
Open the catalog to page 7Measure NO2 directly with the new Serinus® 60 AB O UT ECOT E C H : Problem solving is in our DNA. For over 40 years ECOTECH has pioneered innovative solutions in environmental monitoring for air, water, gas, blast, particulate and dust. Headquartered in Australia, we now operate in more than 80 countries, manage over 440 real-time environmental monitoring sites and are certified to internationally recognised quality standards. ECOTECH is part of the ACOEM Group. +61 3 9730 7800 (International) 1300 364 946 (Australia only) email@ecotech.com ecotech.com Specifications subject to change...
Open the catalog to page 8All Ecotech catalogs and technical brochures
-
Operations & Maintenance
12 Pages
-
Environmental Monitoring
16 Pages
-
ORION
6 Pages
-
VOC1000
1 Pages
-
FUSION
6 Pages
-
DUO
6 Pages
-
CUBE
6 Pages
-
Serinus 51 SO2/H2S Analyser
2 Pages
-
BLAST MONITORING Solutions
4 Pages
-
Serinus Cal
8 Pages
-
SPECTRONUS analyzer
12 Pages
-
ECOTECH Company Profile
16 Pages
-
WINAQMS
4 Pages
-
PROTINUS 1000
2 Pages
-
NH3 Analyser Serinus 44
2 Pages
-
EC9843 NOy analyzer
2 Pages
-
EC9820T CO2 trace analyzer
2 Pages
-
SO2 Analyser EC9850T
2 Pages
-
SO2 Analyser EC9850
2 Pages
-
SO2 Analyser Serinus 50
2 Pages
-
NOx EC9841AS
2 Pages
-
NOx EC9841
2 Pages
-
CO Analyser EC9832
2 Pages
-
CO Analyser Serinus 30H
2 Pages
-
CO Analyser Serinus 30
2 Pages
-
Serinus 10
2 Pages
-
SERINUS Gas Analyser Series
4 Pages
-
GasCal 1100 gas calibrator
2 Pages
-
WinAQMS Data Logger
4 Pages
-
Serinus 10 Ozone Analyzer
2 Pages
-
HiVol 3000 PUF Sampler
2 Pages
-
HiVol 3000 XAD Sampler
2 Pages
-
Converters
2 Pages
Archived catalogs
-
Environmental Monitoring 2019
16 Pages
-
Corporate Profile
6 Pages
-
EC9830T CO trace analyzer
2 Pages
-
EC9811 Ozone photometer
2 Pages
-
EC9841T NOx trace analyzer
2 Pages